DTC
|
P0ABF2A
|
Hybrid/EV Battery Current Sensor "A" Signal Stuck In Range
|
DESCRIPTION
Refer to the description for DTC P0ABF11.
Click here
DTC No.
|
Detection Item
|
DTC Detection Condition
|
Trouble Area
|
MIL
|
Warning Indicate
|
P0ABF2A
|
Hybrid/EV Battery Current Sensor "A" Signal Stuck In Range
|
The battery current sensor output is stuck even when the battery voltage changes.
(1 trip detection logic)
|
-
Battery voltage sensor
-
HV battery junction block assembly
|
Comes on
|
Master Warning:
Comes on
|
Related Data List
DTC No.
|
Data List
|
P0ABF2A
|
Hybrid Battery Current for Hybrid Battery Control*1
|
HINT:
*1: The value of "Hybrid Battery Current for Hybrid Battery Control" usually changes by 4 A or more while the vehicle is accelerating and decelerating.
CONFIRMATION DRIVING PATTERN
HINT:
After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.
Click here
-
Connect the Techstream to the DLC3.
-
Turn the power switch on (IG) and turn the Techstream on.
-
Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
-
Turn the power switch off and wait for 2 minutes or more.
-
Turn the power switch on (IG) and turn the Techstream on.
-
Drive the vehicle on urban roads for approximately 5 minutes.
-
Enter the following menus: Powertrain / Hybrid Control / Utility / All Readiness.
-
Check the DTC judgment result.
HINT:
-
If the judgment result shows NORMAL, the system is normal.
-
If the judgment result shows ABNORMAL, the system has a malfunction.
-
If the judgment result shows INCOMPLETE, perform driving pattern again.
PROCEDURE
1.
|
CHECK DTC OUTPUT (HYBRID CONTROL)
|
(a) Connect the Techstream to the DLC3.
(b) Turn the power switch on (IG).
(c) Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
(d) Check and record any HV system DTCs and freeze frame data.
Powertrain > Hybrid Control > Trouble Codes
Result
|
Proceed to
|
"Only DTC P0ABF2A is output" or "DTC P0ABF2A and DTCs other than those in the following table are output".
|
A
|
DTC P0ABF2A and any of the DTCs in the following table are output at the same time.
|
B
|
Relevant DTC
|
P0A9563
|
High Voltage Fuse Accumulated Load History
|
P0ABF11
|
Hybrid/EV Battery Current Sensor "A" Circuit Short to Ground
|
P0ABF15
|
Hybrid/EV Battery Current Sensor "A" Circuit Short to Auxiliary Battery or Open
|
P0AFC00
|
Hybrid/EV Battery Sensor Module
|
P0AFC96
|
Hybrid/EV Battery Sensor Module Component Internal Failure
|
P1CBB12
|
Hybrid/EV Battery Current Sensor Power Supply Circuit Short to Auxiliary Battery
|
P1CBB14
|
Hybrid/EV Battery Current Sensor Power Supply Circuit Short to Ground or Open
|
P308A12
|
Hybrid/EV Battery Voltage Sensor All Circuit Short to Auxiliary Battery
|
P0B3B14, P0B4014, P0B4514, P0B4A14, P0B4F14, P0B5414, P0B5914, P0B5E14, P0B6314, P0B6814, P0B6D14, P0B7214
|
Hybrid/EV Battery Voltage Sensor "A - L" Circuit Short to Ground or Open
|
(e) Turn the power switch off.
A
|
|
|
2.
|
READ VALUE USING TECHSTREAM
|
(a) Connect the Techstream to the DLC3.
(b) Turn the power switch on (IG).
NOTICE:
Do not turn the power switch on (READY).
(c) Enter the following menus: Powertrain / Hybrid Control / Data List / Hybrid Battery Block 1 to 11 Voltage.
NOTICE:
Select "Hybrid Battery Block 1 to 11 Voltage" only. (Do not select any other Data List items.)
Powertrain > Hybrid Control > Data List
Tester Display
|
Hybrid Battery Block 1 Voltage
|
Hybrid Battery Block 2 Voltage
|
Hybrid Battery Block 3 Voltage
|
Hybrid Battery Block 4 Voltage
|
Hybrid Battery Block 5 Voltage
|
Hybrid Battery Block 6 Voltage
|
Hybrid Battery Block 7 Voltage
|
Hybrid Battery Block 8 Voltage
|
Hybrid Battery Block 9 Voltage
|
Hybrid Battery Block 10 Voltage
|
Hybrid Battery Block 11 Voltage
|
(d) Check the voltage of each "Battery Block Vol" of "Hybrid Battery Block 1 to 11 Voltage" in the Data List with the power switch on (IG).
Specified Condition:
Any "Battery Block Vol" changes by 0.3 V or more, 60 seconds after the power switch is turned on (IG). (The difference between the maximum and minimum voltage is 0.3 V or more.)
Result
|
Proceed to
|
The change in voltage of any "Hybrid Battery Block Voltage" is 0.3 V or more.
|
A
|
Other than above
|
B
|