P06B01C
|
Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range
|
Motor generator control ECU internal malfunction
(1 trip detection logic)
|
Inverter with converter assembly
|
Comes on
|
Master Warning:
Comes on
|
P06D61C
|
Generator Control Module Offset Power Circuit Voltage Out of Range
|
Motor generator control ECU internal malfunction
(1 trip detection logic)
|
Inverter with converter assembly
|
Comes on
|
Master Warning:
Comes on
|
P0A1A47
|
Generator Control Module Watchdog / Safety MC Failure
|
Motor generator control ECU internal malfunction
(1 trip detection logic)
|
Inverter with converter assembly
|
Comes on
|
Master Warning:
Comes on
|
P0A1A49
|
Generator Control Module Internal Electronic Failure
|
Motor generator control ECU internal malfunction
(1 trip detection logic)
|
Inverter with converter assembly
|
Comes on
|
Master Warning:
Comes on
|
P1C2A1C
|
Generator A/D Converter Circuit Circuit Voltage Out of Range
|
Motor generator control ECU internal malfunction
(1 trip detection logic)
|
Inverter with converter assembly
|
Comes on
|
Master Warning:
Comes on
|
P1C2A49
|
Generator A/D Converter Circuit Internal Electronic Failure
|
Motor generator control ECU internal malfunction
(1 trip detection logic)
|
Inverter with converter assembly
|
Comes on
|
Master Warning:
Comes on
|
P1C2B1C
|
Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range
|
Motor generator control ECU internal malfunction
(1 trip detection logic)
|
Inverter with converter assembly
|
Comes on
|
Master Warning:
Comes on
|
P1C2B49
|
Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure
|
Motor generator control ECU internal malfunction
(1 trip detection logic)
|
Inverter with converter assembly
|
Comes on
|
Master Warning:
Comes on
|
P1C601F
|
Generator Control Module Position Sensor REF Power Source Circuit Intermittent
|
Motor generator control ECU internal malfunction detected when DTC P0C7917, P0D3319, P1C5D19 or P1C5F19 is stored.
(1 trip detection logic)
|
Inverter with converter assembly
|
Does not come on
|
Master Warning:
Does not come on
|
P1C621F
|
Generator Control Module Offset Power Circuit Intermittent
|
Motor generator control ECU internal malfunction detected when DTC P0C7917, P0D3319, P1C5D19 or P1C5F19 is stored.
(1 trip detection logic)
|
Inverter with converter assembly
|
Does not come on
|
Master Warning:
Does not come on
|
P313383
|
Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect
|
Motor generator control ECU internal malfunction
(1 trip detection logic)
|
Inverter with converter assembly
|
Comes on
|
Master Warning:
Comes on
|
P313386
|
Communication Error from Generator to Drive Motor "A" Signal Invalid
|
Motor generator control ECU internal malfunction
(1 trip detection logic)
|
Inverter with converter assembly
|
Comes on
|
Master Warning:
Comes on
|
P313387
|
Communication Error from Generator to Drive Motor "A" Missing Message
|
Motor generator control ECU internal malfunction
(1 trip detection logic)
|
Inverter with converter assembly
|
Comes on
|
Master Warning:
Comes on
|
P313483
|
Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect
|
Motor generator control ECU internal malfunction
(1 trip detection logic)
|
Inverter with converter assembly
|
Comes on
|
Master Warning:
Comes on
|
P313486
|
Communication Error from Drive Motor "A" to Generator Signal Invalid
|
Motor generator control ECU internal malfunction
(1 trip detection logic)
|
Inverter with converter assembly
|
Comes on
|
Master Warning:
Comes on
|
P313487
|
Communication Error from Drive Motor "A" to Generator Missing Message
|
Motor generator control ECU internal malfunction
(1 trip detection logic)
|
Inverter with converter assembly
|
Comes on
|
Master Warning:
Comes on
|