Last Modified: 01-30-2024 |
6.11:8.1.0 |
Doc ID: RM100000001EKND |
Model Year Start: 2019 |
Model: RAV4 HV |
Prod Date Range: [11/2018 - 08/2020] |
Title: HYBRID / BATTERY CONTROL: MOTOR GENERATOR CONTROL SYSTEM (for 2WD with NICKEL METAL HYDRIDE BATTERY): P0A4B16,P0A4B1F; Generator Position Sensor Circuit Voltage Below Threshold; 2019 - 2020 MY RAV4 HV [11/2018 - 08/2020] |
DTC
|
P0A4B16
|
Generator Position Sensor Circuit Voltage Below Threshold
|
DTC
|
P0A4B1F
|
Generator Position Sensor Circuit Intermittent
|
DTC SUMMARY
MALFUNCTION DESCRIPTION
These DTCs indicate that the resolver output signal is abnormal. The cause of this malfunction may be one of the following:
Area
|
Main Malfunction Description
|
Inverter low-voltage circuit
|
The connectors are not connected properly
|
Hybrid Vehicle Transaxle Assembly
|
-
Short circuit in the generator resolver circuit
-
Generator (MG1) internal malfunction (entry of foreign matter, etc.)
|
Wire harness between the resolver and inverter with converter assembly
|
-
Short circuit in the wire harness
-
The connectors are not connected properly (entry of foreign matter or water, etc.)
|
Inside of inverter
|
Inverter with converter assembly internal circuit malfunction
|
DESCRIPTION
Refer to the system description for the Generator Resolver Circuit.
Click here
DTC No.
|
Detection Item
|
DTC Detection Condition
|
Trouble Area
|
MIL
|
Warning Indicate
|
P0A4B16
|
Generator Position Sensor Circuit Voltage Below Threshold
|
Interphase short in the generator resolver circuit:
A short circuit between signal lines of generator resolver phases is electrically detected.
(1 trip detection logic)
|
-
Inverter with converter assembly
-
Hybrid vehicle transaxle assembly
-
Wire harness or connector
|
Comes on
|
Master Warning:
Comes on
|
P0A4B1F
|
Generator Position Sensor Circuit Intermittent
|
A short circuit between signal lines of generator resolver phases is electrically detected when DTC P0C7917, P0D3319, P1C5D19 or P1C5F19 is stored.
(1 trip detection logic)
|
-
Inverter with converter assembly
-
Hybrid vehicle transaxle assembly
-
Wire harness or connector
|
Does not come on
|
Master Warning:
Does not come on
|
CONFIRMATION DRIVING PATTERN
HINT:
After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.
Click here
-
Connect the Techstream to the DLC3.
-
Turn the power switch on (IG) and turn the Techstream on.
-
Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
-
Turn the power switch off and wait for 2 minutes or more.
-
Turn the power switch on (IG) and turn the Techstream on.
-
With power switch on (IG) and wait for 5 seconds or more.
-
Turn the power switch on (READY) with the shift lever in P and wait for 5 seconds or more.
-
Depress the accelerator pedal of the vehicle with the engine stopped and the shift lever in P to start the engine.
-
Drive the vehicle forward with the shift lever in D for 5 m (16 ft.) or more.
-
Drive the vehicle backward with the shift lever in R for 5 m (16 ft.) or more.
-
Enter the following menus: Powertrain / Motor Generator / Utility / All Readiness.
-
Check the DTC judgment result.
HINT:
-
If the judgment result shows NORMAL, the system is normal.
-
If the judgment result shows ABNORMAL, the system has a malfunction.
-
If the judgment result shows INCOMPLETE, perform driving pattern again.
WIRING DIAGRAM
Refer to the wiring diagram for the Generator Resolver Circuit.
Click here
CAUTION / NOTICE / HINT
CAUTION:
NOTICE:
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.
Click here
HINT:
-
If the problem symptom cannot be reproduced, performing a road test on a road on which the vehicle tends to vibrate will make it easier to reproduce the symptom.
-
If the resolver is malfunctioning, the vehicle may not drive smoothly.
-
When inspecting the connectors, if it is difficult to judge if a connector was disconnected, deformed or improperly secured, disconnect and reconnect the connector and then check for DTCs again. Check if the same DTC is output. If the same DTC is not output, improper connection of connectors is suspected.
-
As a malfunction detection threshold may be exceeded when performing the vibration or heat connector inspections, make sure to perform the following inspection to check that the DTC was not stored due to the malfunction of a part.
PROCEDURE
(a) Connect the Techstream to the DLC3.
(b) Turn the power switch on (IG).
(c) Enter the following menus: Powertrain / Hybrid Control and Motor Generator / Trouble Codes.
(d) Check for DTCs.
Powertrain > Hybrid Control > Trouble Codes
Powertrain > Motor Generator > Trouble Codes
Result
|
Proceed to
|
P0A4B16 or P0A4B1F only is output, or DTCs except the ones in the table below are also output.
|
A
|
DTCs of hybrid control system in the tables below are output.
|
B
|
DTCs of motor generator control system in the tables below are output.
|
C
|
Table 1
Malfunction Content
|
System
|
Relevant DTC
|
Insulation Malfunction
|
Hybrid control system
|
P1C7C49
|
Hybrid/EV Battery Voltage System Isolation (A/C Area) Internal Electronic Failure
|
P1C7D49
|
Hybrid/EV Battery Voltage System Isolation (Hybrid/EV Battery Area) Internal Electronic Failure
|
P1C7E49
|
Hybrid/EV Battery Voltage System Isolation (Transaxle Area) Internal Electronic Failure
|
P1C7F49
|
Hybrid/EV Battery Voltage System Isolation (Direct Current Area) Internal Electronic Failure
|
Table 2
Malfunction Content
|
System
|
Relevant DTC
|
Power source circuit malfunction
|
Motor generator control system
|
P06B01C
|
Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range
|
P06D61C
|
Generator Control Module Offset Power Circuit Voltage Out of Range
|
HINT:
-
P0A4B16 or P0A4B1F may be output as a result of the malfunctions indicated by the DTCs above.
-
The chart above is listed in inspection order of priority.
-
Check DTCs that are output at the same time by following the listed order. (The main cause of the malfunction can be determined without performing unnecessary inspections.)
(e) Turn the power switch off.
A
|
|
|
2.
|
CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)
|
Click here
Result
|
Proceed to
|
OK
|
A
|
NG (The connector is not connected securely.)
|
B
|
NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.)
|
C
|
B |
|
CONNECT SECURELY
|
C |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR
|
A
|
|
|
3.
|
CHECK GENERATOR RESOLVER CIRCUIT
|
Click here
HINT:
If the "Generator Resolver Circuit" inspection results are normal, perform the next step.
|