(1) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
|
Condition
|
Specified Condition
|
14 (OPN) - 11 (GND)
|
OPEN switch ON
|
Below 100 Ω
|
OPEN switch OFF
|
10 kΩ or higher
|
13 (CLS) - 11 (GND)
|
CLOSE switch ON
|
Below 100 Ω
|
CLOSE switch OFF
|
10 kΩ or higher
|
17 (B) - 11 (GND)
|
Tilt switch ON
|
Below 100 Ω
|
Tilt switch OFF
|
10 kΩ or higher
|
16 (UP) - 11 (GND)
|
Roof sunshade OPEN switch ON
|
Below 100 Ω
|
Roof sunshade OPEN switch OFF
|
10 kΩ or higher
|
15 (DOWN) - 11 (GND)
|
Roof sunshade CLOSE switch ON
|
Below 100 Ω
|
Roof sunshade CLOSE switch OFF
|
10 kΩ or higher
|
If the result is not as specified, replace the sliding roof switch (map light sub-assembly).
|
|
*a
|
Component without harness connected
(Sliding Roof Switch (Map Light Sub-assembly))
|
|
|