                               (a) Measure the resistance according to the value(s) in the table below. 
                              Standard Resistance:  
                              
                                 
                                 
                                 
                                 
                                    
                                       | 
                                           Tester Connection 
                                        | 
                                       
                                           Condition 
                                        | 
                                       
                                           Specified Condition 
                                        | 
                                     
                                 
                                 
                                    
                                       | 
                                           1 - 2 
                                        | 
                                       
                                           10°C (50°F) 
                                        | 
                                       
                                           3.00 to 3.73 kΩ 
                                        | 
                                     
                                    
                                       | 
                                           15°C (59°F) 
                                        | 
                                       
                                           2.45 to 2.88 kΩ 
                                        | 
                                     
                                    
                                       | 
                                           20°C (68°F) 
                                        | 
                                       
                                           1.95 to 2.30 kΩ 
                                        | 
                                     
                                    
                                       | 
                                           25°C (77°F) 
                                        | 
                                       
                                           1.60 to 1.80 kΩ 
                                        | 
                                     
                                    
                                       | 
                                           30°C (86°F) 
                                        | 
                                       
                                           1.28 to 1.47 kΩ 
                                        | 
                                     
                                    
                                       | 
                                           35°C (95°F) 
                                        | 
                                       
                                           1.00 to 1.22 kΩ 
                                        | 
                                     
                                    
                                       | 
                                           40°C (104°F) 
                                        | 
                                       
                                           0.80 to 1.00 kΩ 
                                        | 
                                     
                                    
                                       | 
                                           45°C (113°F) 
                                        | 
                                       
                                           0.65 to 0.85 kΩ 
                                        | 
                                     
                                    
                                       | 
                                           50°C (122°F) 
                                        | 
                                       
                                           0.50 to 0.70 kΩ 
                                        | 
                                     
                                    
                                       | 
                                           55°C (131°F) 
                                        | 
                                       
                                           0.44 to 0.60 kΩ 
                                        | 
                                     
                                    
                                       | 
                                           60°C (140°F) 
                                        | 
                                       
                                           0.36 to 0.50 kΩ 
                                        | 
                                     
                                 
                               
                              
                                 NOTICE: 
                                 
                                    - 
Hold the sensor only by its connector. Touching the sensing portion may change the resistance value.
 
                                    - 
When measuring, the sensor temperature. must be the same as the ambient temperature.
 
                                  
                               
                              HINT: 
                              As the temperature increases, the resistance decreases (see the graph). 
                              
                                 
                                    - 
If the result is not as specified, replace the cooler thermistor (room temperature sensor).
 
                                  
                               
                            | 
                           
                              
                                 
                                    
                                        
                                     | 
                                  
                                 
                                    
                                       
                                          
                                             
                                             
                                          
                                          
                                             
                                                | 
                                                    *a 
                                                 | 
                                                
                                                    Component without harness connected 
                                                   (Cooler thermistor (room temperature sensor)) 
                                                 | 
                                              
                                             
                                                | 
                                                    *b 
                                                 | 
                                                
                                                    Sensing Portion 
                                                 | 
                                              
                                             
                                                | 
                                                    *c 
                                                 | 
                                                
                                                    Resistance (kΩ) 
                                                 | 
                                              
                                             
                                                | 
                                                    *d 
                                                 | 
                                                
                                                    Temperature (°C (°F)) 
                                                 | 
                                              
                                             
                                                | 
                                                    *e 
                                                 | 
                                                
                                                    Allowable Range 
                                                 | 
                                              
                                          
                                        
                                     | 
                                  
                               
                            |