(a) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
|
Condition
|
Specified Condition
|
1 - 2
|
-10°C (14°F)
|
7.30 to 9.10 kΩ
|
-5°C (23°F)
|
5.65 to 6.95 kΩ
|
0°C (32°F)
|
4.40 to 5.35 kΩ
|
5°C (41°F)
|
3.40 to 4.15 kΩ
|
10°C (50°F)
|
2.70 to 3.25 kΩ
|
15°C (59°F)
|
2.14 to 2.58 kΩ
|
20°C (68°F)
|
1.71 to 2.05 kΩ
|
25°C (77°F)
|
1.38 to 1.64 kΩ
|
30°C (86°F)
|
1.11 to 1.32 kΩ
|
NOTICE:
-
Hold the sensor only by its connector. Touching the sensor may change the resistance value.
-
When measuring, the sensor temperature must be the same as the ambient temperature.
HINT:
As the temperature increases, the resistance decreases (See the graph).
If the result is not as specified, replace the No. 1 cooler thermistor.
|
|
*a
|
Component without harness connected
(No. 1 Cooler Thermistor)
|
*b
|
Sensing Portion
|
*c
|
Resistance (kΩ)
|
*d
|
Temperature (°C (°F))
|
|
|