Last Modified: 01-30-2024 |
6.11:8.1.0 |
Doc ID: RM100000001FCM9 |
Model Year Start: 2019 |
Model: RAV4 HV |
Prod Date Range: [11/2018 -
] |
Title: A25A-FXS (COOLING): FLOW SHUTTING VALVE: INSPECTION; 2019 - 2024 MY RAV4 HV [11/2018 - ] |
INSPECTION
PROCEDURE
1. INSPECT FLOW SHUTTING VALVE (WATER BY-PASS HOSE ASSEMBLY)
(a) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
|
Condition
|
Specified Condition
|
1 - 2
|
20°C (68°F)
|
22 to 28 Ω
|
If the result is not as specified, replace the flow shutting valve (water by-pass hose assembly).
|