                           Last Modified: 05-08-2025 | 
                        6.11:8.1.0  | 
                        
                           Doc ID: RM100000001FCM9 | 
                      
                     
                        | 
                           Model Year Start: 2019 | 
                        
                           Model: RAV4 HV | 
                        
                           Prod Date Range: [11/2018 -                    
                                       ] | 
                      
                     
                        | 
                           Title: A25A-FXS (COOLING): FLOW SHUTTING VALVE: INSPECTION; 2019 - 2025 MY RAV4 HV [11/2018 -        ] | 
                      
                   
                  INSPECTION
                   
                  PROCEDURE
                   
                  1. INSPECT FLOW SHUTTING VALVE (WATER BY-PASS HOSE ASSEMBLY) 
                  (a) Measure the resistance according to the value(s) in the table below. 
                  Standard Resistance:  
                  
                     
                        
                        
                        
                     
                     
                        
                           | 
                               Tester Connection 
                            | 
                           
                               Condition 
                            | 
                           
                               Specified Condition 
                            | 
                         
                     
                     
                        
                           | 
                               1 - 2 
                            | 
                           
                               20°C (68°F) 
                            | 
                           
                               22 to 28 Ω 
                            | 
                         
                     
                   
                  If the result is not as specified, replace the flow shutting valve (water by-pass hose assembly). 
                  
                |