Last Modified: 01-30-2024 |
6.11:8.1.0 |
Doc ID: RM100000001FHGG |
Model Year Start: 2019 |
Model: RAV4 HV |
Prod Date Range: [11/2018 - 08/2020] |
Title: A25A-FXS (ENGINE CONTROL): SFI SYSTEM (w/o Canister Pump Module): P019011; Fuel Rail Pressure Sensor "A" Circuit Short to Ground; 2019 - 2020 MY RAV4 HV [11/2018 - 08/2020] |
DTC
|
P019011
|
Fuel Rail Pressure Sensor "A" Circuit Short to Ground
|
DESCRIPTION
The fuel pressure sensor (for high pressure side) is installed on the fuel delivery pipe (for high pressure side). The fuel pressure sensor (for high pressure side) changes the fuel pressure for high pressure side into an electrical signal and sends the signal to the ECM. Then the ECM controls the pump discharge using this feedback to maintain the fuel's target pressure between 3.0 and 25 MPa (30 and 254 kgf/cm2, 435 and 3626 psi).
DTC No.
|
Detection Item
|
DTC Detection Condition
|
Trouble Area
|
MIL
|
Memory
|
Note
|
P019011
|
Fuel Rail Pressure Sensor "A" Circuit Short to Ground
|
The fuel pressure sensor (for high pressure side) output voltage is less than 0.2933 V for 3 seconds or more (1 trip detection logic).
|
-
Open or short in fuel pressure sensor (for high pressure side) circuit
-
Fuel pressure sensor (for high pressure side)
-
ECM
|
Comes on
|
DTC stored
|
SAE Code: P0192
|
HINT:
When this DTC is output, check the fuel pressure (for high pressure side) in the Data List. Enter the following menus: Powertrain / Engine / Data List / Fuel Pressure (High).
DTC No.
|
Fuel Pressure (High)
|
Malfunction
|
P019011
|
Approximately 0 kPag
|
-
Short to ground in PR circuit
-
Short in PR to EPR circuit
-
Open in VCPR circuit
|
If the Data List values are normal, it may be due to a temporary recovery from the malfunction condition. Check for intermittent problems.
Click here
MONITOR DESCRIPTION
This DTC is stored if the fuel pressure sensor (for high pressure side) output voltage is out of the standard range due to an open or short in the sensor circuit.
Example:
If the fuel pressure sensor (for high pressure side) output voltage is less than 0.2933 V for 3 seconds or more, the ECM will illuminate the MIL and store this DTC.
MONITOR STRATEGY
Required Sensors/Components
|
Fuel pressure sensor (for high pressure side)
|
Frequency of Operation
|
Continuous
|
CONFIRMATION DRIVING PATTERN
-
Connect the Techstream to the DLC3.
-
Turn the power switch on (IG).
-
Turn the Techstream on.
-
Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
-
Turn the power switch off and wait for at least 30 seconds.
-
Turn the power switch on (IG).
-
Turn the Techstream on.
-
Put the engine in Inspection Mode (Maintenance Mode).
Click here
-
Start the engine [A].
-
Idle the engine for 10 seconds [B].
-
Enter the following menus: Powertrain / Engine / Trouble Codes [C].
-
Read the pending DTCs.
HINT:
-
If a pending DTC is output, the system is malfunctioning.
-
If a pending DTC is not output, perform the following procedure.
-
Enter the following menus: Powertrain / Engine / Utility / All Readiness.
-
Input the DTC: P019011.
-
Check the DTC judgment result.
Techstream Display
|
Description
|
NORMAL
|
-
DTC judgment completed
-
System normal
|
ABNORMAL
|
-
DTC judgment completed
-
System abnormal
|
INCOMPLETE
|
-
DTC judgment not completed
-
Perform driving pattern after confirming DTC enabling conditions
|
HINT:
-
If the judgment result is NORMAL, the system is normal.
-
If the judgment result is ABNORMAL, the system has a malfunction.
-
If the judgment result is INCOMPLETE, perform steps [B] through [C] again.
WIRING DIAGRAM
CAUTION / NOTICE / HINT
HINT:
Read Freeze Frame Data using the Techstream. The ECM records vehicle and driving condition information as Freeze Frame Data the moment a DTC is stored. When troubleshooting, Freeze Frame Data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, if the air fuel ratio was lean or rich, and other data from the time the malfunction occurred.
PROCEDURE
1.
|
CHECK HARNESS AND CONNECTOR
|
*a
|
Front view of wire harness connector
(to Fuel Pressure Sensor (for High Pressure Side))
|
HINT:
Make sure that the connector is properly connected. If it is not, securely connect it and check for DTCs again.
(a) Disconnect the fuel pressure sensor (for high pressure side) connector.
(b) Turn the power switch on (IG).
(c) Measure the voltage according to the value(s) in the table below.
Standard Voltage:
Tester Connection
|
Condition
|
Specified Condition
|
F2-1 (VC) - F2-2 (E2)
|
Power switch on (IG)
|
4.75 to 5.25 V
|
F2-3 (PR) - F2-2 (E2)
|
Power switch on (IG)
|
3.0 to 5.25 V
|
(d) Turn the power switch off and wait for at least 30 seconds.
(e) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
|
Condition
|
Specified Condition
|
F2-1 (VC) - F2-3 (PR)
|
Power switch off
|
171 to 189 kΩ
|
HINT:
Perform "Inspection After Repair" after replacing the fuel pressure sensor (for high pressure side).
Click here
NG
|
|
|
2.
|
CHECK HARNESS AND CONNECTOR (FUEL PRESSURE SENSOR (FOR HIGH PRESSURE SIDE) - ECM)
|
(a) Disconnect the fuel pressure sensor (for high pressure side) connector.
(b) Disconnect the ECM connector.
(c) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
|
Condition
|
Specified Condition
|
F2-1 (VC) - C45-98 (VCPR)
|
Always
|
Below 1 Ω
|
F2-3 (PR) or C45-97 (PR) - Body ground and other terminals
|
Always
|
10 kΩ or higher
|
NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR
|
|