| 
                               (2) Measure the voltage according to the value(s) in the table below. 
                              Standard Voltage:  
                              
                                 
                                 
                                 
                                 
                                    
                                       | 
                                           Tester Connection 
                                        | 
                                       
                                           Float Level 
                                        | 
                                       
                                           Specified Condition 
                                        | 
                                     
                                 
                                 
                                    
                                       | 
                                           1 - 2 
                                        | 
                                       
                                           F 
                                        | 
                                       
                                           4.255 to 4.605 V* 
                                        | 
                                     
                                    
                                       | 
                                           Between F and E 
                                        | 
                                       
                                           0.345 to 4.605 V* (Gradually changes) 
                                        | 
                                     
                                    
                                       | 
                                           E 
                                        | 
                                       
                                           0.345 to 0.695 V* 
                                        | 
                                     
                                 
                               
                              *: The output voltage changes depending on the voltage applied to the terminals. 
                              Output voltage (F) = (0.851 x Voltage applied to terminals) to (0.921 x Voltage applied to terminals) 
                              Output voltage (E) = (0.069 x Voltage applied to terminals) to (0.139 x Voltage applied to terminals) 
                              If the result is not as specified, replace the fuel sender gauge assembly. 
                            |