(a) Inspect the headlight dimmer relay (H-LP LH relay).
(1) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
|
Auxiliary Battery Connection
|
Specified Condition
|
3 - 5
|
Auxiliary battery voltage is not applied to terminals 1 and 2
|
10 kΩ or higher
|
Auxiliary battery voltage is applied to terminals 1 and 2
|
Below 1 Ω
|
|