                           Last Modified: 05-08-2025 | 
                        6.11:8.1.0  | 
                        
                           Doc ID: RM100000001FOO0 | 
                      
                     
                        | 
                           Model Year Start: 2019 | 
                        
                           Model: RAV4 | 
                        
                           Prod Date Range: [11/2018 -                    
                                       ] | 
                      
                     
                        | 
                           Title: UB80E (AUTOMATIC TRANSMISSION / TRANSAXLE): AUTOMATIC TRANSAXLE SYSTEM: P275614; Torque Converter Clutch Pressure Control Solenoid Control Circuit Short to Ground or Open; 2019 - 2025 MY RAV4 [11/2018 -        ] | 
                      
                   
                  
                     
                        
                           | 
                               DTC 
                            | 
                           
                               P275614 
                            | 
                           
                               Torque Converter Clutch Pressure Control Solenoid Control Circuit Short to Ground or Open 
                            | 
                         
                     
                   
                   
                  DESCRIPTION
                  Refer to DTC P275612. 
                  Click here
                        
                           
                               
                           
                        
                     
                   
                  
                     
                        
                        
                        
                        
                        
                        
                        
                     
                     
                        
                           | 
                               DTC No. 
                            | 
                           
                               Detection Item 
                            | 
                           
                               DTC Detection Condition 
                            | 
                           
                               Trouble Area 
                            | 
                           
                               MIL 
                            | 
                           
                               Memory 
                            | 
                           
                               Note 
                            | 
                         
                     
                     
                        
                           | 
                               P275614 
                            | 
                           
                               Torque Converter Clutch Pressure Control Solenoid Control Circuit Short to Ground or Open 
                            | 
                           
                               While the vehicle is being driven, a short to ground or open is detected in the solenoid (SLU) valve circuit for 1 second or more (1-trip detection logic). 
                            | 
                           
                              
                                 
                                    - 
Solenoid (SLU) valve
 
                                    - 
Transmission wire
 
                                    - 
Harness and connector
 
                                    - 
ECM
 
                                  
                               
                            | 
                           
                               Comes on 
                            | 
                           
                               DTC stored 
                            | 
                           
                               SAE Code: 
                              P2764 
                            | 
                         
                     
                   
                   
                  MONITOR DESCRIPTION
                  When an open or short to ground in the solenoid (SLU) valve circuit is detected, the ECM will determine that there is a malfunction, illuminate the MIL and store this DTC. 
                   
                  MONITOR STRATEGY
                  
                     
                        
                        
                     
                     
                        
                           | 
                               Related DTCs 
                            | 
                           
                               P2764: Solenoid (SLU) valve/Range check (Low current) 
                            | 
                         
                        
                           | 
                               Required sensors/components 
                            | 
                           
                               Solenoid (SLU) valve 
                            | 
                         
                        
                           | 
                               Frequency of operation 
                            | 
                           
                               Continuous 
                            | 
                         
                        
                           | 
                               Duration 
                            | 
                           
                               1 second 
                            | 
                         
                        
                           | 
                               MIL operation 
                            | 
                           
                               Immediate 
                            | 
                         
                        
                           | 
                               Sequence of operation 
                            | 
                           
                               None 
                            | 
                         
                     
                   
                   
                  TYPICAL ENABLING CONDITIONS
                  
                     
                        
                        
                     
                     
                        
                           | 
                               The monitor will run whenever the following DTCs are not stored 
                            | 
                           
                               None 
                            | 
                         
                        
                           | 
                               Solenoid current cut status 
                            | 
                           
                               Not cut 
                            | 
                         
                        
                           | 
                               Ignition switch 
                            | 
                           
                               ON 
                            | 
                         
                        
                           | 
                               Starter 
                            | 
                           
                               OFF 
                            | 
                         
                        
                           | 
                               Battery voltage 
                            | 
                           
                               10.5 V or higher 
                            | 
                         
                        
                           | 
                               Target current (0.1 seconds or more) 
                            | 
                           
                               0.2 A or higher 
                            | 
                         
                     
                   
                   
                  TYPICAL MALFUNCTION THRESHOLDS
                  
                     
                        
                        
                     
                     
                        
                           | 
                               Solenoid current 
                            | 
                           
                               Below 0.075 A 
                            | 
                         
                     
                   
                   
                  COMPONENT OPERATING RANGE
                  
                     
                        
                        
                     
                     
                        
                           | 
                               Solenoid current 
                            | 
                           
                               0.075 A or higher 
                            | 
                         
                     
                   
                   
                  CONFIRMATION DRIVING PATTERN
                  CAUTION: 
                  When performing the confirmation driving pattern, obey all speed limits and traffic laws. 
                  
                     HINT: 
                     
                        - 
After repairs have been completed, clear the DTCs and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.
 
                        - 
When clearing the permanent DTCs, refer to the Clear Permanent DTC procedure.
Click here
                                 
                                    
                                        
                                    
                                 
                              
                            
                         
                      
                   
                  
                     
                        - 
Connect the Techstream to the DLC3.
 
                        - 
Turn the ignition switch to ON and turn the Techstream on.
 
                        - 
Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
 
                        - 
Turn the ignition switch off and wait for 30 seconds or more.
 
                        - 
Turn the ignition switch to ON and turn the Techstream on.
 
                        - 
Start the engine.
 
                        - 
Perform the Lock-up Function inspection in Road Test. [*1]
Click here
                                 
                                    
                                        
                                    
                                 
                              
                            
                           HINT: 
                           [*1]: Normal judgment procedure. 
                           The normal judgment procedure is used to complete DTC judgment and also used when clearing permanent DTCs. 
                         
                        - 
Stop the vehicle.
 
                        - 
Enter the following menus: Powertrain / Transmission / Utility / All Readiness.
 
                        - 
Input the DTC: P275614.
 
                        - 
Check the DTC judgment result.
                              
                                 
                                 
                              
                              
                                 
                                    | 
                                        Techstream Display 
                                     | 
                                    
                                        Description 
                                     | 
                                  
                              
                              
                                 
                                    | 
                                        NORMAL 
                                     | 
                                    
                                       
                                          
                                             - 
DTC judgment completed
 
                                             - 
System normal
 
                                           
                                        
                                     | 
                                  
                                 
                                    | 
                                        ABNORMAL 
                                     | 
                                    
                                       
                                          
                                             - 
DTC judgment completed
 
                                             - 
System abnormal
 
                                           
                                        
                                     | 
                                  
                                 
                                    | 
                                        INCOMPLETE 
                                     | 
                                    
                                       
                                          
                                             - 
DTC judgment not completed
 
                                             - 
Perform driving pattern after confirming DTC enabling conditions
 
                                           
                                        
                                     | 
                                  
                                 
                                    | 
                                        N/A 
                                     | 
                                    
                                       
                                          
                                             - 
Unable to perform DTC judgment
 
                                             - 
Number of DTCs which do not fulfill DTC preconditions has reached ECU memory limit
 
                                           
                                        
                                     | 
                                  
                              
                            
                           
                              HINT: 
                              
                                 - 
If the judgment result shows NORMAL, the system is normal.
 
                                 - 
If the judgment result shows ABNORMAL, the system has a malfunction.
 
                                 - 
If the judgment result shows INCOMPLETE or N/A, perform the normal judgment procedure again.
 
                               
                            
                         
                      
                   
                   
                  WIRING DIAGRAM
                  Refer to DTC P275612. 
                  Click here
                        
                           
                               
                           
                        
                     
                   
                   
                  CAUTION / NOTICE / HINT
                  
                     NOTICE: 
                     
                        - 
Perform the universal trip to clear permanent DTCs.
Click here
                                 
                                    
                                        
                                    
                                 
                              
                            
                         
                        - 
Perform registration and/or initialization when parts related to the automatic transaxle are replaced.
Click here
                                 
                                    
                                        
                                    
                                 
                                 
                                    
                                        
                                    
                                 
                              
                            
                         
                      
                   
                   
                  PROCEDURE
                   
                  
                     
                        
                           | 
                               1.  
                            | 
                           
                               CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE (SOLENOID (SLU) VALVE) - ECM) 
                            | 
                         
                     
                   
                  (a) Disconnect the ECM connector. 
                  (b) Measure the resistance according to the value(s) in the table below. 
                  Standard Resistance:  
                  
                     
                        
                        
                        
                     
                     
                        
                           | 
                               Tester Connection 
                            | 
                           
                               Condition 
                            | 
                           
                               Specified Condition 
                            | 
                         
                     
                     
                        
                           | 
                               C41-12 (SLU+) - C41-11 (SLU-) 
                            | 
                           
                               20°C (68°F) 
                            | 
                           
                               5.0 to 5.6 Ω 
                            | 
                         
                        
                           | 
                               C41-12 (SLU+) or C41-11 (SLU-) - Body ground and other terminals 
                            | 
                           
                               Always 
                            | 
                           
                               10 kΩ or higher 
                            | 
                         
                     
                   
                  
                  
                     
                        
                           
                              
                                 | 
OK
 | 
                               
                              
                                 
                                     
                                  | 
                               
                            
                         | 
                      
                   
                   
                  
                  (a) Replace the ECM. 
                  Click here
                        
                           
                               
                           
                        
                        
                           
                               
                           
                        
                        
                           
                               
                           
                        
                        
                           
                               
                           
                        
                     
                   
                  
                   
                  
                     
                        
                           | 
                               3.  
                            | 
                           
                               CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM) 
                            | 
                         
                     
                   
                  (a) Disconnect the transmission wire connector. 
                  (b) Disconnect the ECM connector. 
                  (c) Measure the resistance according to the value(s) in the table below. 
                  Standard Resistance:  
                  
                     
                        
                        
                        
                     
                     
                        
                           | 
                               Tester Connection 
                            | 
                           
                               Condition 
                            | 
                           
                               Specified Condition 
                            | 
                         
                     
                     
                        
                           | 
                               C30-5 (SLU+) - C41-12 (SLU+) 
                            | 
                           
                               Always 
                            | 
                           
                               Below 1 Ω 
                            | 
                         
                        
                           | 
                               C30-4 (SLU-) - C41-11 (SLU-) 
                            | 
                           
                               Always 
                            | 
                           
                               Below 1 Ω 
                            | 
                         
                        
                           | 
                               C30-5 (SLU+) or C41-12 (SLU+) - Body ground and other terminals 
                            | 
                           
                               Always 
                            | 
                           
                               10 kΩ or higher 
                            | 
                         
                        
                           | 
                               C30-4 (SLU-) or C41-11 (SLU-) - Body ground and other terminals 
                            | 
                           
                               Always 
                            | 
                           
                               10 kΩ or higher 
                            | 
                         
                     
                   
                  
                     
                        
                           | NG | 
                           
                               
                            | 
                           
                               REPAIR OR REPLACE HARNESS OR CONNECTOR (TRANSMISSION WIRE - ECM) 
                            | 
                         
                     
                   
                  
                     
                        
                           
                              
                                 | 
OK
 | 
                               
                              
                                 
                                     
                                  | 
                               
                            
                         | 
                      
                   
                   
                  
                     
                        
                           | 
                               4.  
                            | 
                           
                               INSPECT SOLENOID (SLU) VALVE 
                            | 
                         
                     
                   
                  
                     
                        
                           | 
                               (a) Remove the solenoid (SLU) valve. 
                              Click here
                                    
                                       
                                           
                                       
                                    
                                    
                                       
                                           
                                       
                                    
                                 
                               
                            | 
                           
                              
                                 
                                    
                                        
                                     | 
                                  
                                 
                                    
                                       
                                          
                                             
                                             
                                          
                                          
                                             
                                                | 
                                                    *a 
                                                 | 
                                                
                                                    Component without harness connected 
                                                   (Solenoid (SLU) Valve) 
                                                 | 
                                              
                                          
                                        
                                     | 
                                  
                               
                            | 
                         
                     
                   
                  (b) Measure the resistance according to the value(s) in the table below. 
                  Standard Resistance:  
                  
                     
                        
                        
                        
                     
                     
                        
                           | 
                               Tester Connection 
                            | 
                           
                               Condition 
                            | 
                           
                               Specified Condition 
                            | 
                         
                     
                     
                        
                           | 
                               Solenoid (SLU) valve connector terminal 1 - terminal 2 
                            | 
                           
                               20°C (68°F) 
                            | 
                           
                               5.0 to 5.6 Ω 
                            | 
                         
                     
                   
                  (c) Connect a positive (+) lead from the battery with a 21 W bulb to terminal 1 and a negative (-) lead to terminal 2 of the solenoid valve connector. Check that the valve moves and makes an operating sound. 
                  OK:  
                  Valve moves and makes operating sound. 
                  
                  
                  
                |