S-FLOW Control Auto Function
|
Function to turn the S-FLOW control on automatically when the ignition switch is turned to ON (for Automatic Air Conditioning System)
|
ON
|
0:ON,1:OFF
|
Air conditioning amplifier assembly
|
Set Temperature Shift
|
Function to perform control with the shifted temperature versus the displayed temperature (for Automatic Air Conditioning System)
|
Normal
|
00001:-2C,00010:-1C,00100:Normal,01000:+1C,10000:+2C
|
Air conditioning amplifier assembly
|
Evaporator Control
|
Function to set the evaporator control to the automatic position (Automatic) to save power or to the coldest position (Manual) to dehumidify the air and to prevent the windows from fogging up
|
Automatic
|
0:Automatic,1:Manual
|
Air conditioning amplifier assembly
|
Compressor Mode
|
Function to turn the A/C on automatically by pressing the AUTO button when the blower is on and the A/C is off (for Automatic Air Conditioning System)
|
Automatic
|
0:Automatic,1:Manual
|
Air conditioning amplifier assembly
|
Air Inlet Mode
|
Function to change the mode automatically to recirculation air mode when turning the A/C on to cool the cabin quickly (for Automatic Air Conditioning System)
|
Automatic
|
0:Automatic,1:Manual
|
Air conditioning amplifier assembly
|
Foot/DEF Auto Mode
|
Function to turn the airflow to foot/defroster automatically when AUTO mode is on (for Automatic Air Conditioning System)
|
ON
|
0:ON,1:OFF
|
Air conditioning amplifier assembly
|
Foot/DEF Automatic Blow Up Function
|
Function to increase the blower level automatically when the defroster is on (for Automatic Air Conditioning System)
|
ON
|
0:ON,1:OFF
|
Air conditioning amplifier assembly
|
Ambient Temperature Shift
|
Function to display the shifted ambient temperature versus the actual ambient temperature
|
Normal
|
0000001:-3C,0000010:-2C,0000100:-1C,0001000:Normal,0010000:+1C,0100000:+2C,1000000:+3C
|
Air conditioning amplifier assembly
|
ECO MODE Cancel
|
Function to cancel ECO mode when set to ON
|
ON
|
0:OFF,1:ON
|
Air conditioning amplifier assembly
|
Refrigerant Shortage Check
|
Function to cancel the refrigerant shortage check (check performed during normal operation) when set to ON
|
ON
|
0:ON,1:OFF
|
Air conditioning amplifier assembly
|
Fan speed increment control
|
Function to set the speed to reach the target blower fan speed when AUTO mode is on (for Automatic Air Conditioning System)
|
Normal
|
001:Slow,010:Normal,100:Fast
|
Air conditioning amplifier assembly
|
Outside Air Mode Auto Switch Function
|
Function to automatically change the air inlet to FRESH mode when the ignition switch is off for 60 seconds
|
ON
|
0:ON,1:OFF
|
Air conditioning amplifier assembly
|