B1411
|
Room Temperature Sensor Circuit
|
-
Diagnosis condition: Ambient temperature is -30°C (-22°F) or more
-
Malfunction status: Open or short in room temperature sensor circuit
-
Detection time: None (Present malfunction), continuously for 4 seconds or more (Past malfunction)
|
|
B1412
|
Ambient Temperature Sensor Circuit
|
-
Diagnosis condition: None
-
Malfunction status: Open or short in ambient temperature sensor circuit
-
Detection time: None (Present malfunction), continuously for 4 seconds or more (Past malfunction)
|
|
B1413
|
Evaporator Temperature Sensor Circuit
|
-
Diagnosis condition: None
-
Malfunction status: Open or short in evaporator temperature sensor circuit
-
Detection time: None (Present malfunction), continuously for 4 seconds or more (Past malfunction)
|
|
B1423
|
Pressure Sensor Circuit
|
-
Diagnosis condition: Ignition switch ON
-
Malfunction Status: Refrigerant pressure signal malfunction
-
Detection time: Continuously for 4 seconds or more (Present malfunction)
|
|
B1441
|
Air Mix Damper Control Servo Motor Circuit (Passenger Side)
|
-
Diagnosis condition: During No. 1 air conditioning radiator damper servo sub-assembly (front passenger side air mix)*1 or No. 1 air conditioning radiator damper servo sub-assembly (air mix)*2 operation
-
Malfunction status: The damper servo operation request signal is output but the position information of the servo does not change or servo is malfunctioning
-
Detection time: Continuously for 30 seconds or more
|
|
B1442
|
Air Inlet Damper Control Servo Motor Circuit
|
-
Diagnosis condition: During No. 1 blower damper servo sub-assembly operation
-
Malfunction status: The damper servo operation request signal is output but the position information of the servo does not change or servo is malfunctioning
-
Detection time: Continuously for 30 seconds or more
|
|
B1443
|
Air Outlet Damper Control Servo Motor Circuit
|
-
Diagnosis condition: During No. 1 air conditioning radiator damper servo sub-assembly (driver side mode) operation
-
Malfunction status: The damper servo operation request signal is output but the position information of the servo does not change or servo is malfunctioning
-
Detection time: Continuously for 30 seconds or more
|
|
B1446
|
Air Mix Damper Control Servo Motor Circuit (Driver Side)
|
-
Diagnosis condition: During No. 1 air conditioning radiator damper servo sub-assembly (driver side air mix) operation
-
Malfunction status: The damper servo operation request signal is output but the position information of the servo does not change or servo is malfunctioning
-
Detection time: Continuously for 30 seconds or more
|
|
B1448
|
Passenger Side FACE Servo Motor Circuit
|
-
Diagnosis condition: During No. 3 air conditioning radiator damper servo sub-assembly (front passenger side mode) operation
-
Malfunction status: The damper servo operation request signal is output but the position information of the servo does not change or servo is malfunctioning
-
Detection time: Continuously for 30 seconds or more
|
|
B1449
|
Air Outlet Damper Control Servo Motor Circuit (Rear)
|
-
Diagnosis condition: During No. 2 air conditioning radiator damper servo sub-assembly (rear mode) operation
-
Malfunction status: The damper servo operation request signal is output but the position information of the servo does not change or servo is malfunctioning
-
Detection time: Continuously for 30 seconds or more
|
|
B1451
|
Compressor Solenoid Circuit
|
Open or short in compressor solenoid circuit
|
|
B1497
|
Communication Malfunction (Bus Ic)
|
-
Diagnosis condition: None
-
Malfunction status: Error or open in communication line between air conditioning amplifier assembly and servo motor
|
|
B14B2
|
Lost Communication with Front Panel LIN
|
Lost communication with air conditioning control assembly
-
Diagnosis condition: Ignition switch ON
-
Malfunction status: Lost communication with air conditioning control assembly
-
Detection time: Continuously for 10 seconds or more
|
|
B14B8
|
Refrigerant Shortage
|
-
Diagnosis condition: The amount of refrigerant is judged to be insufficient in normal operation
-
Malfunction status: When following condition is detected in refrigerant shortage check in normal operation; Amount of refrigerant is insufficient
-
Detection time: During air conditioning system operation for 10 minutes or more
|
|
B14BD
|
Refrigerant Overabundance Filling Malfunction
|
All of the following conditions are met 2 times or more in the same trip:
-
The vehicle speed is 20 km/h (12.4 mph) or more
-
The amount of compressor oil is within the insufficient compressor oil range for 60 seconds or more
|
|
U0100
|
Lost Communication with ECM / PCM "A"
|
No communication with ECM
|
|
U0131
|
Lost Communication with Power Steering Control Module
|
No communication with rack and pinion power steering gear assembly (power steering ECU assembly)
|
|
U0142
|
Lost Communication with Body Control Module "B"
|
No communication with main body ECU (multiplex network body ECU)
|
|
U0151
|
Lost Communication with Restraints Control Module
|
No communication with airbag sensor assembly
|
|
U0155
|
Lost Communication with Instrument Panel Cluster (IPC) Control Module
|
No communication with combination meter assembly
|
|