Last Modified: 01-30-2024 |
6.11:8.1.0 |
Doc ID: RM100000001FPEC |
Model Year Start: 2019 |
Model: RAV4 |
Prod Date Range: [11/2018 -
] |
Title: HEATING / AIR CONDITIONING: AIR CONDITIONING SYSTEM (for Gasoline Model): B1449; Air Outlet Damper Control Servo Motor Circuit (Rear); 2019 - 2024 MY RAV4 [11/2018 - ] |
DTC
|
B1449
|
Air Outlet Damper Control Servo Motor Circuit (Rear)
|
DESCRIPTION
The No. 2 air conditioning radiator damper servo sub-assembly (rear mode) sends pulse signals to inform the air conditioning amplifier assembly of the damper position. The air conditioning amplifier assembly activates the motor (normal or reverse) based on these signals to move the air outlet damper to the appropriate position, which controls the rear air outlet switching. The air conditioning amplifier assembly communicates with the servo through a communication/driver IC and wiring assembly called the air conditioning harness assembly.
DTC No.
|
Detection Item
|
DTC Detection Condition
|
Trouble Area
|
Memory
|
B1449
|
Air Outlet Damper Control Servo Motor Circuit (Rear)
|
-
Diagnosis condition: During No. 2 air conditioning radiator damper servo sub-assembly (rear mode) operation
-
Malfunction status: The damper servo operation request signal is output but the position information of the servo does not change or servo is malfunctioning
-
Detection time: Continuously for 30 seconds or more
|
-
No. 2 air conditioning radiator damper servo sub-assembly (rear mode)
-
Air conditioning harness assembly
-
Air conditioning radiator assembly
-
Air conditioning amplifier assembly
|
Memorized
|
-
*: The air conditioning amplifier assembly stores this DTC if the malfunction has occurred for the period of time indicated in the brackets.
DTC Detection Condition Combination Table
|
Vehicle Condition
|
Pattern 1
|
Pattern 2
|
Diagnosis Condition
|
No. 2 air conditioning radiator damper servo sub-assembly (rear mode) operating
|
○
|
○
|
Malfunction
|
Air outlet damper servo operation request signals are output but the rear air outlet damper position sensor value does not change
|
○
|
-
|
Air outlet damper servo operation request signals are output but the rear air outlet damper position sensor value is abnormal
|
-
|
○
|
Detection Time
|
Continuously for 30 seconds or more
|
Continuously for 30 seconds or more
|
Trip Count
|
1 trip
|
1 trip
|
HINT:
If the conditions of either of these patterns are detected, a DTC will be stored
WIRING DIAGRAM
CAUTION / NOTICE / HINT
HINT:
-
Confirm that no mechanical problems are present because this DTC can be stored when either a damper link or damper is mechanically locked.
-
When installing a servo motor, make sure to install it correctly.
-
When the servo motor is replaced, be sure to perform servo motor initialization.
Click here
PROCEDURE
(a) Check for DTCs.
Click here
Body Electrical > Air Conditioner > Trouble Codes
Result
|
Proceed to
|
DTC B1449 is output
|
A
|
DTC B1449 and B1497 are output
|
B
|
A
|
|
|
2.
|
INSPECT NO. 2 AIR CONDITIONING RADIATOR DAMPER SERVO SUB-ASSEMBLY (INSTALLATION CONDITION)
|
(a) Check that the No. 2 air conditioning radiator damper servo sub-assembly is installed correctly.
OK:
The No. 2 air conditioning radiator damper servo sub-assembly is installed correctly.
OK
|
|
|
3.
|
INSPECT NO. 2 AIR CONDITIONING RADIATOR DAMPER SERVO SUB-ASSEMBLY (MOTOR, LINK, DAMPER)
|
(a) Check for a wire harness caught between the links of the motors and dampers.
OK:
No wire harnesses are caught between the links of the motors and dampers.
NG |
|
REMOVE PINCHED WIRE HARNESS
|
OK
|
|
|
4.
|
PERFORM ACTIVE TEST USING TECHSTREAM
|
(a) Using the Techstream, perform the following Active Test and read the Data List value.
Body Electrical > Air Conditioner > Active Test
Tester Display
|
Measurement Item
|
Control Range
|
Diagnostic Note
|
A/O Servo Pulse(Rr D)
|
No. 2 air conditioning radiator damper servo sub-assembly pulse
|
Min.: 128
Max.: 383
|
Operates between 158 to 260 pulses
|
Body Electrical > Air Conditioner > Data List
Tester Display
|
Measurement Item
|
Range
|
Normal Condition
|
Diagnostic Note
|
Air Outlet Servo Actual Pls(R)
|
No. 2 air conditioning radiator damper servo sub-assembly actual pulse
|
Min.: 128
Max.: 383
|
-
FACE: 260 (pulse)
-
FOOT-R, D, O, F/D: 223 (pulse)
-
B/L: 212 (pulse)
-
FOOT-F: 182 (pulse)
-
D/F: 177 (pulse)
-
DEF: 158 (pulse)
|
-
|
Body Electrical > Air Conditioner > Active Test
Active Test Display
|
A/O Servo Pulse(Rr D)
|
Data List Display
|
Air Outlet Servo Actual Pls(R)
|
OK:
The value of the Data List changes in accordance with the operation of the Active Test.
OK
|
|
|
5.
|
PERFORM ACTIVE TEST USING TECHSTREAM
|
(a) Using the Techstream, perform the following Active Test and read the Data List value.
Body Electrical > Air Conditioner > Active Test
Tester Display
|
Measurement Item
|
Control Range
|
Diagnostic Note
|
A/O Servo Pulse(Rr D)
|
No. 2 air conditioning radiator damper servo sub-assembly pulse
|
Min.: 128
Max.: 383
|
Operates between 158 to 260 pulses
|
Body Electrical > Air Conditioner > Data List
Tester Display
|
Measurement Item
|
Range
|
Normal Condition
|
Diagnostic Note
|
Air Outlet Servo Pulse (R)
|
No. 2 air conditioning radiator damper servo sub-assembly target pulse
|
Min.: 128
Max.: 383
|
-
FACE: 260 (pulse)
-
F/D: 223 (pulse)
-
B/L: 212 (pulse)
-
FOOT: 182 (pulse)
-
D/F: 177 (pulse)
-
SHUT: 158 (pulse)
|
-
|
Air Outlet Servo Actual Pls(R)
|
No. 2 air conditioning radiator damper servo sub-assembly actual pulse
|
Min.: 128
Max.: 383
|
-
FACE: 260 (pulse)
-
F/D: 223 (pulse)
-
B/L: 212 (pulse)
-
FOOT: 182 (pulse)
-
D/F: 177 (pulse)
-
SHUT: 158 (pulse)
|
-
|
Body Electrical > Air Conditioner > Active Test
Active Test Display
|
A/O Servo Pulse(Rr D)
|
Data List Display
|
Air Outlet Servo Pulse (R)
|
Air Outlet Servo Actual Pls(R)
|
OK:
The target pulse value of the Data List matches the actual pulse.
NG
|
|
|
6.
|
REPLACE NO. 2 AIR CONDITIONING RADIATOR DAMPER SERVO SUB-ASSEMBLY
|
HINT:
Click here
NEXT
|
|
|
7.
|
PERFORM ACTIVE TEST USING TECHSTREAM
|
(a) Using the Techstream, perform the following Active Test and read the Data List value.
Body Electrical > Air Conditioner > Active Test
Tester Display
|
Measurement Item
|
Control Range
|
Diagnostic Note
|
A/O Servo Pulse(Rr D)
|
No. 2 air conditioning radiator damper servo sub-assembly pulse
|
Min.: 128
Max.: 383
|
Operates between 158 to 260 pulses
|
Body Electrical > Air Conditioner > Data List
Tester Display
|
Measurement Item
|
Range
|
Normal Condition
|
Diagnostic Note
|
Air Outlet Servo Actual Pls(R)
|
No. 2 air conditioning radiator damper servo sub-assembly actual pulse
|
Min.: 128
Max.: 383
|
-
FACE: 260 (pulse)
-
F/D: 223 (pulse)
-
B/L: 212 (pulse)
-
FOOT: 182 (pulse)
-
D/F: 177 (pulse)
-
SHUT: 158 (pulse)
|
-
|
Body Electrical > Air Conditioner > Active Test
Active Test Display
|
A/O Servo Pulse(Rr D)
|
Data List Display
|
Air Outlet Servo Actual Pls(R)
|
OK:
The value of the Data List changes in accordance with the operation of the Active Test.
OK |
|
END
|
8.
|
PERFORM ACTIVE TEST USING TECHSTREAM
|
(a) Using the Techstream, perform the following Active Test and read the Data List value.
Body Electrical > Air Conditioner > Active Test
Tester Display
|
Measurement Item
|
Control Range
|
Diagnostic Note
|
Air Outlet Servo Pulse (D)
|
No. 1 air conditioning radiator damper servo sub-assembly (driver side mode) pulse
|
Min.: 128
Max.: 383
|
w/ Driver Seat Centralized Control
-
Operates between 164 to 278 pulses
w/ Front Seat Centralized Control
-
Operates between 234 to 348 pulses
|
Body Electrical > Air Conditioner > Data List
Tester Display
|
Measurement Item
|
Range
|
Normal Condition
|
Diagnostic Note
|
Air Outlet Servo Actu Pulse(D)
|
No. 1 air conditioning radiator damper servo sub-assembly (driver side mode) actual pulse
|
Min.: 128
Max.: 383
|
w/ Driver Seat Centralized Control
-
S-FLOW: 278 (pulse)
-
FACE: 256 (pulse)
-
B/L: 245 (pulse)
-
FOOT-A: 224 (pulse)
-
FOOT-R (F): 215 (pulse)
-
FOOT-D: 207 (pulse)
-
F/D-R: 192 (pulse)
-
D/F: 173 (pulse)
-
DEF: 164 (pulse)
w/ Front Seat Centralized Control
-
S-FLOW: 234 (pulse)
-
FACE: 256 (pulse)
-
B/L: 267 (pulse)
-
FOOT-A: 288 (pulse)
-
FOOT-R (F): 297 (pulse)
-
FOOT-D: 305 (pulse)
-
F/D-R: 320 (pulse)
-
D/F: 339 (pulse)
-
DEF: 348 (pulse)
|
-
|
Body Electrical > Air Conditioner > Active Test
Active Test Display
|
Air Outlet Servo Pulse (D)
|
Data List Display
|
Air Outlet Servo Actu Pulse(D)
|
OK:
The value of the Data List changes in accordance with the operation of the Active Test.
NG
|
|
|
9.
|
INSPECT AIR CONDITIONING RADIATOR ASSEMBLY (DAMPER)
|
(a) Remove the No. 2 air conditioning radiator damper servo sub-assembly.
Click here
(b) Operate the dampers by hand.
OK:
The dampers are easily operated by hand.
NG |
|
REPLACE AIR CONDITIONING RADIATOR ASSEMBLY
|
|