Title: HEATING / AIR CONDITIONING: AIR CONDITIONING SYSTEM (for Gasoline Model): Front Window Fogging; 2019 - 2020 MY RAV4 [11/2018 - 08/2020] |
DESCRIPTION
If the front glass frequently fogs up when the air conditioning system is operated, the following causes are possible.
Malfunction Status
|
Factor
|
Front glass frequently fogs
|
-
Compressor with pulley assembly malfunction
-
Lack of refrigerant gas
-
Cooler expansion valve (opened too far)
-
Mode damper servo malfunction
-
Mode damper and link operation (jamming)
|
PROCEDURE
1.
|
CHECK REFRIGERANT SHORTAGE
|
(a) Connect the Techstream to the DLC3.
(b) Turn the ignition switch to ON.
(c) Turn the Techstream on.
(d) Enter the following menus: Body Electrical / Air Conditioner / Utility / Refrigerant Gas Volume Check.
Body Electrical > Air Conditioner > Utility
Tester Display
|
Refrigerant Gas Volume Check
|
(e) Check that the following conditions are met and perform the refrigerant shortage check according to the display on the Techstream.
Measurement Condition:
Item
|
Condition
|
Vehicle Condition
|
Engine running
|
A/C Switch
|
On
|
Ambient Temperature*1
|
0 to 49°C (32 to 120°F)
|
Air Conditioning Air Inlet Temperature*2
|
25 to 35°C (77 to 95°F)
|
Set Temperature
|
MAX COLD
|
Recirculation/fresh Control Switch
|
Recirculation
|
Air Vent Damper Position
|
FACE
|
Blower Speed
|
HI
|
HINT:
-
Refer to the Techstream operator's manual for further details.
-
A message indicating a refrigerant shortage is displayed on the Techstream and the air conditioning system turns off if the amount of refrigerant in the system is insufficient.
-
DTCs are not stored when performing the refrigerant shortage check using the Techstream.
-
*1: This inspection can be judged correctly only if the ambient temperature is within a range of 0 to 49°C (32 to 120°F). Therefore, postpone the test if the temperature is low.
-
*2: This inspection can be judged correctly only if the air inlet temperature is within a range of 25 to 35°C (77 to 95°F). Therefore, postpone the test if the temperature is out of range.
Result
|
Amount of Refrigerant
|
Refrigerant shortage
|
Insufficient or leakage
|
Refrigerant correct
|
Correct
|
OK:
"Refrigerant correct" is displayed on the Techstream.
OK
|
|
|
(a) When the MODE switch on the air conditioning control assembly is pushed, check that the air conditioning system changes DEF mode according to the switch operation.
OK:
Air conditioning system changes DEF mode.
|