Last Modified: 01-30-2024 |
6.11:8.1.0 |
Doc ID: RM100000001FPGQ |
Model Year Start: 2019 |
Model: RAV4 HV |
Prod Date Range: [11/2018 - 02/2019] |
Title: HEATING / AIR CONDITIONING: AIR CONDITIONING SYSTEM (for HV Model): UTILITY; 2019 MY RAV4 HV [11/2018 - 02/2019] |
UTILITY
REFRIGERANT HIGH PRESSURE HISTORY CLEAR
(a) Connect the Techstream to the DLC3.
(b) Turn the power switch on (IG).
(c) Turn the Techstream on.
(d) Enter the following menus: Body Electrical / Air Conditioner / Utility / Refrigerant High Pressure History Clear.
Body Electrical > Air Conditioner > Utility
Tester Display
|
Refrigerant High Pressure History Clear
|
REFRIGERANT SHORTAGE CHECK USING TECHSTREAM
(a) Connect the Techstream to the DLC3.
(b) Turn the power switch on (IG).
(c) Turn the Techstream on.
(d) Enter the following menus: Body Electrical / Air Conditioner / Utility / Refrigerant Gas Volume Check.
Body Electrical > Air Conditioner > Utility
Tester Display
|
Refrigerant Gas Volume Check
|
(e) Check that the following conditions are met and perform the refrigerant shortage check according to the display on the Techstream.
Measurement Condition:
Item
|
Condition
|
Vehicle Condition
|
Power switch on (READY)
|
A/C Switch
|
On
|
Ambient Temperature*1
|
0 to 49°C (32 to 120°F)
|
Air Conditioning Air Inlet Temperature*2
|
25 to 35°C (77 to 95°F)
|
Set Temperature
|
MAX COLD
|
Recirculation/fresh Control Switch
|
Recirculation
|
Air Vent Damper Position
|
FACE
|
Blower Speed
|
HI
|
HINT:
-
Refer to the Techstream operator's manual for further details.
-
A message indicating a refrigerant shortage is displayed on the Techstream and the air conditioning system turns off if the amount of refrigerant in the system is insufficient.
-
DTCs are not stored when performing the refrigerant shortage check using the Techstream.
-
*1: This inspection can be judged correctly only if the ambient temperature is within a range of 0 to 49°C (32 to 120°F). Therefore, postpone the test if the temperature is low.
-
*2: This inspection can be judged correctly only if the air inlet temperature is within a range of 25 to 35°C (77 to 95°F). Therefore, postpone the test if the temperature is out of range.
Result:
Result
|
Amount of Refrigerant
|
Corrective Action
|
Refrigerant shortage
|
Insufficient
|
-
Check for refrigerant leaks using a halogen leak detector, and repair if necessary.
-
Evacuate the air conditioning system and charge it with the appropriate volume of new or purified refrigerant.
-
for HFC-134a (R134a):
-
for HFO-1234yf (R1234yf):
|
Refrigerant correct
|
Correct
|
-
|
Refrigerant incorrect
|
Incorrect
|
Confirm check condition and carry out again
|
|