                  REFRIGERANT HIGH PRESSURE HISTORY CLEAR 
                  (a) Connect the Techstream to the DLC3. 
                  (b) Turn the power switch on (IG). 
                  (c) Turn the Techstream on. 
                  (d) Enter the following menus: Body Electrical / Air Conditioner / Utility / Refrigerant High Pressure History Clear. 
                  Body Electrical > Air Conditioner > Utility
                  
                     
                        
                     
                     
                        
                           | 
                               Tester Display 
                            | 
                         
                     
                     
                        
                           | 
                               Refrigerant High Pressure History Clear 
                            | 
                         
                     
                   
                  REFRIGERANT SHORTAGE CHECK USING TECHSTREAM 
                  (a) Connect the Techstream to the DLC3. 
                  (b) Turn the power switch on (IG). 
                  (c) Turn the Techstream on. 
                  (d) Enter the following menus: Body Electrical / Air Conditioner / Utility / Refrigerant Gas Volume Check. 
                  Body Electrical > Air Conditioner > Utility
                  
                     
                        
                     
                     
                        
                           | 
                               Tester Display 
                            | 
                         
                     
                     
                        
                           | 
                               Refrigerant Gas Volume Check 
                            | 
                         
                     
                   
                  (e) Check that the following conditions are met and perform the refrigerant shortage check according to the display on the Techstream. 
                  Measurement Condition:
                  
                     
                        
                        
                     
                     
                        
                           | 
                               Item 
                            | 
                           
                               Condition 
                            | 
                         
                     
                     
                        
                           | 
                               Vehicle Condition 
                            | 
                           
                               Power switch on (READY) 
                            | 
                         
                        
                           | 
                               A/C Switch 
                            | 
                           
                               On 
                            | 
                         
                        
                           | 
                               Ambient Temperature*1 
                            | 
                           
                               0 to 49°C (32 to 120°F) 
                            | 
                         
                        
                           | 
                               Air Conditioning Air Inlet Temperature*2 
                            | 
                           
                               25 to 35°C (77 to 95°F) 
                            | 
                         
                        
                           | 
                               Set Temperature 
                            | 
                           
                               MAX COLD 
                            | 
                         
                        
                           | 
                               Recirculation/fresh Control Switch 
                            | 
                           
                               Recirculation 
                            | 
                         
                        
                           | 
                               Air Vent Damper Position 
                            | 
                           
                               FACE 
                            | 
                         
                        
                           | 
                               Blower Speed 
                            | 
                           
                               HI 
                            | 
                         
                     
                   
                  
                     HINT: 
                     
                        - 
Refer to the Techstream operator's manual for further details.
 
                        - 
A message indicating a refrigerant shortage is displayed on the Techstream and the air conditioning system turns off if the amount of refrigerant in the system is insufficient.
 
                        - 
DTCs are not stored when performing the refrigerant shortage check using the Techstream.
 
                        - 
*1: This inspection can be judged correctly only if the ambient temperature is within a range of 0 to 49°C (32 to 120°F). Therefore, postpone the test if the temperature is low.
 
                        - 
*2: This inspection can be judged correctly only if the air inlet temperature is within a range of 25 to 35°C (77 to 95°F). Therefore, postpone the test if the temperature is out of range.
 
                      
                   
                  Result:
                  
                     
                        
                        
                        
                     
                     
                        
                           | 
                               Result 
                            | 
                           
                               Amount of Refrigerant 
                            | 
                           
                               Corrective Action 
                            | 
                         
                     
                     
                        
                           | 
                               Refrigerant shortage 
                            | 
                           
                               Insufficient 
                            | 
                           
                              
                                 
                                    - 
Check for refrigerant leaks using a halogen leak detector, and repair if necessary.
 
                                    - 
Evacuate the air conditioning system and charge it with the appropriate volume of new or purified refrigerant.
                                          
                                             - 
for HFC-134a (R134a):
                                                   
                                                      
                                                         
 
                                                      
                                                   
                                                
                                              
                                             - 
for HFO-1234yf (R1234yf):
                                                   
                                                      
                                                         
 
                                                      
                                                   
                                                
                                              
                                           
                                        
                                     
                                  
                               
                            | 
                         
                        
                           | 
                               Refrigerant correct 
                            | 
                           
                               Correct 
                            | 
                           
                               - 
                            | 
                         
                        
                           | 
                               Refrigerant incorrect 
                            | 
                           
                               Incorrect 
                            | 
                           