                               G47-1 (TAM) - G47-14 (SG-2) 
                            | 
                           
                               R - R 
                            | 
                           
                               Ambient temperature sensor signal 
                            | 
                           
                              
                                 
                                    - 
Power switch on (IG) (do not start the engine and electric motor)
 
                                    - 
Ambient temperature: 25°C (77°F)
 
                                  
                               
                            | 
                           
                               1.05 to 1.45 V 
                            | 
                        
                        
                           
                              
                                 
                                    - 
Power switch on (IG) (do not start the engine and electric motor)
 
                                    - 
Ambient temperature: 40°C (104°F)
 
                                  
                               
                            | 
                           
                               0.64 to 0.87 V 
                            | 
                        
                        
                           | 
                               G47-3 (SG-1) - Body ground 
                            | 
                           
                               G - Body ground 
                            | 
                           
                               Ground for sensor 
                            | 
                           
                               Always 
                            | 
                           
                               Below 1 Ω 
                            | 
                        
                        
                           | 
                               G47-5 (TR) - Body ground 
                            | 
                           
                               GR - Body ground 
                            | 
                           
                               Room temperature sensor signal 
                            | 
                           
                              
                                 
                                    - 
Power switch on (IG)
 
                                    - 
Cabin temperature: 25°C (77°F)
 
                                  
                               
                            | 
                           
                               1.05 to 1.45 V 
                            | 
                        
                        
                           
                              
                                 
                                    - 
Power switch on (IG)
 
                                    - 
Cabin temperature: 40°C (104°F)
 
                                  
                               
                            | 
                           
                               0.64 to 0.87 V 
                            | 
                        
                        
                           | 
                               G47-6 (PRE) - G47-15 (SG-4) 
                            | 
                           
                               GR - L 
                            | 
                           
                               Air conditioner pressure sensor signal 
                            | 
                           
                              
                                 
                                    - 
Power switch on (READY)
 
                                    - 
Air conditioning system operating
 
                                    - 
Refrigerant pressure: Normal pressure (below 3025 kPa [30.8 kgf/cm2, 439 psi] and higher than 176 kPa [1.8 kgf/cm2, 26 psi])
 
                                  
                               
                            | 
                           
                               0.74 to 4.61 V 
                            | 
                        
                        
                           
                              
                                 
                                    - 
Power switch on (READY)
 
                                    - 
Air conditioning system operating
 
                                    - 
Refrigerant pressure: Abnormal pressure (less than 176 kPa (1.8 kgf/cm2, 26 psi))
 
                                  
                               
                            | 
                           
                               Below 0.74 V 
                            | 
                        
                        
                           
                              
                                 
                                    - 
Power switch on (READY)
 
                                    - 
Air conditioning system operating
 
                                    - 
Refrigerant pressure: Abnormal pressure (more than 3025 kPa (30.8 kgf/cm2, 439 psi))
 
                                  
                               
                            | 
                           
                               4.61 V or higher 
                            | 
                        
                        
                           | 
                               G47-11 (S5-3) - Body ground 
                            | 
                           
                               L - Body ground 
                            | 
                           
                               Power source of sensor 
                            | 
                           
                               Power switch off → on (IG) 
                            | 
                           
                               Below 1 V → 4.75 to 5.25 V 
                            | 
                        
                        
                           | 
                               G47-14 (SG-2) - Body ground 
                            | 
                           
                               R - Body ground 
                            | 
                           
                               Ground for sensor 
                            | 
                           
                               Always 
                            | 
                           
                               Below 1 Ω 
                            | 
                        
                        
                           | 
                               G47-15 (SG-4) - Body ground 
                            | 
                           
                               L - Body ground 
                            | 
                           
                               Ground for sensor 
                            | 
                           
                               Always 
                            | 
                           
                               Below 1 Ω 
                            | 
                        
                        
                           | 
                               G46-1 (CANL) 
                            | 
                           
                               - 
                            | 
                           
                               CAN communication line 
                            | 
                           
                               - 
                            | 
                           
                               - 
                            | 
                        
                        
                           | 
                               G46-2 (CANH) 
                            | 
                           
                               - 
                            | 
                           
                               CAN communication line 
                            | 
                           
                               - 
                            | 
                           
                               - 
                            | 
                        
                        
                           | 
                               G46-7 (LIN1) - Body ground 
                            | 
                           
                               BE - Body ground 
                            | 
                           
                               LIN communication signal 
                            | 
                           
                               Power switch on (IG) 
                            | 
                           
                               Pulse generation 
                              (See waveform 1) 
                            | 
                        
                        
                           | 
                               G46-11 (ECOS) - Body ground 
                            | 
                           
                               W - Body ground 
                            | 
                           
                               Integration control and panel assembly (ECO switch) signal 
                            | 
                           
                              
                                 
                                    - 
Power switch on (IG)
 
                                    - 
Integration control and panel assembly (ECO switch) Off → On
 
                                  
                               
                            | 
                           
                               11 to 14 V → Below 1 V 
                            | 
                        
                        
                           | 
                               G46-21 (BLW) - Body ground 
                            | 
                           
                               Y - Body ground 
                            | 
                           
                               Blower motor speed control signal 
                            | 
                           
                              
                                 
                                    - 
Power switch on (IG)
 
                                    - 
Blower switch: LO
 
                                  
                               
                            | 
                           
                               Pulse generation 
                              (See waveform 2) 
                            | 
                        
                        
                           | 
                               z11-2 (BUS G) - Body ground 
                            | 
                           
                               - 
                            | 
                           
                               Ground for BUS IC 
                            | 
                           
                               Always 
                            | 
                           
                               Below 1 Ω 
                            | 
                        
                        
                           | 
                               z11-3 (BUS) - z11-2 (BUS G) 
                            | 
                           
                               - 
                            | 
                           
                               BUS IC control signal 
                            | 
                           
                               Power switch on (IG) 
                            | 
                           
                               Pulse generation 
                              (See waveform 3) 
                            | 
                        
                        
                           | 
                               z11-4 (B BUS) - z11-2 (BUS G) 
                            | 
                           
                               - 
                            | 
                           
                               Power supply for BUS IC 
                            | 
                           
                               Power switch off 
                            | 
                           
                               11 to 14 V 
                            | 
                        
                        
                           | 
                               z11-5 (SGA) - Body ground 
                            | 
                           
                               - 
                            | 
                           
                               Ground for No. 1 cooler thermistor 
                            | 
                           
                               Always 
                            | 
                           
                               Below 1 Ω 
                            | 
                        
                        
                           | 
                               z11-6 (TEA) - z11-5 (SGA) 
                            | 
                           
                               - 
                            | 
                           
                               No. 1 cooler thermistor signal 
                            | 
                           
                              
                                 
                                    - 
Power switch on (IG)
 
                                    - 
Evaporator temperature: 0°C (32°F)
 
                                  
                               
                            | 
                           
                               1.7 to 2.1 V 
                            | 
                        
                        
                           
                              
                                 
                                    - 
Power switch on (IG)
 
                                    - 
Evaporator temperature: 15°C (59°F)
 
                                  
                               
                            | 
                           
                               0.9 to 1.3 V 
                            |