                  DESCRIPTION
                  If the blower airflow volume is weak regardless of the integration control and panel assembly being normal, the following causes are possible. 
                  
                     
                        
                        
                     
                     
                        
                           | 
                               Malfunction Status 
                            | 
                           
                               Factor 
                            | 
                         
                     
                     
                        
                           
                              
                                 
                                    - 
Blower airflow volume is continuously weak
 
                                    - 
Blower airflow volume is sometimes weak
 
                                  
                               
                            | 
                           
                              
                                 
                                    - 
Communication malfunction between air conditioning amplifier assembly and blower with fan motor sub-assembly
 
                                    - 
Air conditioning amplifier assembly malfunction
 
                                    - 
Blower with fan motor sub-assembly malfunction
 
                                    - 
Clean air filter is clogging
 
                                    - 
Evaporator or heater core fin clogging
 
                                    - 
ECO drive mode function (air flow volume is restricted due to ECO drive mode being selected)
 
                                    - 
Aspirator dropped
 
                                  
                               
                            | 
                         
                     
                   
                   
                  PROCEDURE
                   
                  
                     
                        
                           | 
                               1.  
                            | 
                           
                               CHECK BLOWER FAN OPERATION 
                            | 
                         
                     
                   
                  (a) Prepare the vehicle according to the table below in manual mode. 
                  
                     
                        
                        
                     
                     
                        
                           | 
                               Blower Switch 
                            | 
                           
                               Condition 
                            | 
                         
                     
                     
                        
                           | 
                               LO → HI 
                            | 
                           
                              
                                 
                                    - 
Temperature setting: Max COLD
 
                                    - 
Mode switch: FACE
 
                                    - 
A/C switch: Off
 
                                  
                               
                            | 
                         
                     
                   
                  OK:  
                  Airflow volume is changed. 
                  
                  
                     
                        
                           
                              
                                 | 
OK
 | 
                               
                              
                                 
                                     
                                  | 
                               
                            
                         | 
                      
                   
                   
                  
                     
                        
                           | 
                               2.  
                            | 
                           
                               CHECK ECO DRIVE MODE OPERATION 
                            | 
                         
                     
                   
                  (a) Confirm setup of the ECO drive mode and turn it off if it is on. 
                  
                     HINT: 
                     
                        - 
When ECO drive mode is on, the air conditioning amplifier assembly ensures a minimum level of air conditioning control based on certain conditions, thereby contributing to improved fuel efficiency. Accordingly, explain to customers that the air volume will be weaker in these situations.
                              
                                 
                                 
                              
                              
                                 
                                    | 
                                        Control 
                                     | 
                                    
                                        Control Summary 
                                     | 
                                  
                              
                              
                                 
                                    | 
                                        Airflow Control 
                                     | 
                                    
                                        Automatically switches the air inlet port to the internal air circulation mode when the outside air temperature is equal to or higher than a predetermined temperature and reduces the power consumption. 
                                     | 
                                  
                                 
                                    | 
                                        Air Inlet Control 
                                     | 
                                    
                                        Sets the blower level in AUTO mode lower than normal, and suppresses the power consumption. 
                                     | 
                                  
                              
                            
                         
                        - 
If integration control and panel assembly (ECO switch) is malfunctioning, perform diagnosis on the ECO switch circuit.
Click here
                                 
                                    
                                        
                                    
                                 
                                 
                                    
                                        
                                    
                                 
                              
                            
                         
                      
                   
                  
                     
                        
                           
                              
                                 | 
NEXT
 | 
                               
                              
                                 
                                     
                                  | 
                               
                            
                         | 
                      
                   
                   
                  
                     
                        
                           | 
                               3.  
                            | 
                           
                               CHECK CLEAN AIR FILTER 
                            | 
                         
                     
                   
                  (a) Visually check the clean air filter. 
                  OK:  
                  The clean air filter is not dirty or clogging. 
                  
                  
                     
                        
                           
                              
                                 | 
OK
 | 
                               
                              
                                 
                                     
                                  | 
                               
                            
                         | 
                      
                   
                   
                  
                     
                        
                           | 
                               4.  
                            | 
                           
                               CHECK NO. 1 COOLER THERMISTOR 
                            | 
                         
                     
                   
                  (a) Check the installation condition of the No. 1 cooler thermistor. 
                  OK:  
                  No. 1 cooler thermistor is installed correctly. 
                  
                  
                     
                        
                           
                              
                                 | 
OK
 | 
                               
                              
                                 
                                     
                                  | 
                               
                            
                         | 
                      
                   
                   
                  
                  (a) Check the installation condition of the aspirator. 
                  OK:  
                  Aspirator is installed correctly. 
                  
                     
                        
                           | OK | 
                           
                               
                            | 
                           
                               REPLACE HEATER RADIATOR UNIT SUB-ASSEMBLY OR NO. 1 COOLER EVAPORATOR (HEATER RADIATOR UNIT SUB-ASSEMBLY OR NO. 1 COOLER EVAPORATOR WAS CLOGGING) 
                            | 
                         
                     
                   
                  
                  
                |