Door Lock Status
|
Back door condition signal
|
Lock or Unlock
|
Lock: Back door locked
Unlock: Back door unlocked
|
-
|
Half Latch SW
|
Latch switch signal
|
ON or OFF
|
ON: Back door lock motor open-latched
OFF: Back door lock motor full-latched or half-latched
|
-
|
Closer Position SW
|
Initial switch signal
|
ON or OFF
|
ON: Back door lock sector gear in center position (Initial switch on)
OFF: Back door lock sector gear out of center position (Initial switch off)
|
-
|
Pawl Position Switch
|
Pawl switch signal
|
ON or OFF
|
ON: Back door lock motor open-latched
OFF: Back door lock motor except open-latched
|
-
|
Courtesy SW
|
Back door courtesy switch signal
|
ON or OFF
|
ON: Back door open
OFF: Back door closed
|
-
|
PBD Touch Sensor (Right)
|
Power back door sensor assembly RH signal
|
ON, OFF or Open
|
ON: Power back door sensor assembly RH pressed
OFF: Power back door sensor assembly RH not pressed
Open: Power back door sensor assembly RH circuit open
|
-
|
PBD Touch Sensor (Left)
|
Power back door sensor assembly LH signal
|
ON, OFF or Open
|
ON: Power back door sensor assembly LH pressed
OFF: Power back door sensor assembly LH not pressed
Open: Power back door sensor assembly LH circuit open
|
-
|
PBD Main SW
|
Power back door ON/OFF signal
|
ON or OFF
|
Current customize setting displayed
|
-
|
PBD Close SW
|
No. 1 power back door control switch signal
|
ON or OFF
|
ON: No. 1 power back door control switch pushed
OFF: No. 1 power back door control switch not pushed
|
-
|
IG SW
|
Power switch signal
|
ON or OFF
|
ON: Power switch on (IG)
OFF: Power switch off
|
"OFF" is also displayed for this item when the power switch is on (ACC).
|
Door Lock Signal
|
Back door condition signal
|
Lock or Unlock
|
Lock: Back door locked
Unlock: Back door unlocked
|
-
|
PBD Position (3/4-Open)
|
Load signal detected during back door closing operation (3/4 - Open)
|
Caution or OK
|
Caution: Load detected between back door 3/4 and fully open position during back door closing operation
OK: No load detected between back door 3/4 and fully open position during back door closing operation
|
-
|
PBD Position (2/4-3/4)
|
Load signal detected during back door closing operation (2/4 - 3/4)
|
Caution or OK
|
Caution: Load detected between back door 2/4 and 3/4 open position during back door closing operation
OK: No load detected between back door 2/4 and 3/4 open position during back door closing operation
|
-
|
PBD Position (1/4-2/4)
|
Load signal detected during back door closing operation (1/4 - 2/4)
|
Caution or OK
|
Caution: Load detected between back door 1/4 and 2/4 open position during back door closing operation
OK: No load detected between back door 1/4 and 2/4 open position during back door closing operation
|
-
|
PBD Position (Close-1/4)
|
Load signal detected during back door closing operation (Close - 1/4)
|
Caution or OK
|
Caution: Load detected between back door fully closed and 1/4 open position during back door closing operation
OK: No load detected between back door fully closed and 1/4 open position during back door closing operation
|
-
|
Closed Position Initialization
|
Back door fully closed position memorized signal
|
Not Initialized or Initialized
|
Not Initialized: Back door fully closed position not memorized
Initialized: Back door fully closed position memorized
|
-
|
PBD SW Operation
|
Power back door switch operation
|
ON or 0.8 s
|
Current customize setting displayed
|
-
|
PBD Buzz In Use
|
Power back door warning buzzer operation condition signal
|
ON or OFF
|
Current customize setting displayed
|
-
|
PBD Assist Open Operation
|
Function that enables or disables the power back door assist open operation. When PBD Assist Open Operation is set to on (enabled) the back door will open automatically when the back door opener switch assembly (opener switch) is operated.
|
OFF or ON
|
Current customize setting displayed
|
-
|
PBD Assist Close Operation
|
Function that automatically fully closes the back door when a stopped back door is moved by hand in the closing direction.
|
OFF or ON
|
Current customize setting displayed
|
-
|
Door Unlock with 1 Motion.
|
Door or doors to be unlocked when back door locked and power back door operated by pressing transmitter switch (electrical key transmitter sub-assembly).
|
BackDoor or ALL DOORS
|
Current customize setting displayed
|
-
|
Wireless Power Back Door Open
|
Function that operates the power back door by pushing the transmitter switch (electrical key transmitter sub-assembly).
|
Lock:OFF/Unlock:OFF, Lock:OFF/Unlock:ON, Lock:OFF/Unlock:Twice, Lock:OFF/Unlock:0.8s, Lock:Twice/Unlock:Twice or Lock:0.8s/Unlock:0.8s
|
Current customize setting displayed
|
-
|
Power Back Door Opening Adjust
|
Function that can be used to set the power back door opening angle at 6 different positions.
|
User Setting Position, Min, Small, Middle, Large or Max
|
Current customize setting displayed
|
-
|
Emblem Sensor
|
Rear emblem sensor assembly connection status.*1
|
Without or With
|
Without: Rear emblem sensor assembly not connected
With: Rear emblem sensor assembly connected
|
Not applicable
|
Emblem Sensor Detection
|
Rear emblem sensor assembly detection status.*1
|
OFF or ON
|
OFF: Rear emblem sensor assembly not detecting a hand
ON: Rear emblem sensor assembly detecting a hand
|
Not applicable
|
PBD/Emblem Sensor Function
|
Function that enables/disables the power back door and rear emblem sensor assembly.*1
|
PBD OFF/Emblem OFF, PBD ON/Emblem OFF or PBD ON/Emblem ON
|
Current customize setting displayed
|
Not applicable
|
PBD Buzzer Volume Adjust
|
Function that changes the power back door buzzer setting.
|
Small, Middle of Large
|
Current customize setting displayed
|
-
|
Emblem Sensor Detection Sensitivity
|
Function that changes the sensitivity of the rear emblem sensor assembly.*1
|
Low, Middle or High
|
Current customize setting displayed
|
Not applicable
|
Emblem Sensor Sensitivity Reduction Mode Transition Frequency (Frequent Contact/Calibration Failure)
|
Number of times emblem sensor changed to sensitivity reduction mode (frequent contact/calibration failure)*1
|
None, Low, Middle or High
|
None: Never
Low: 1 to 10 times
Middle: 11 to 50 times
High: 51 times or more
|
Not applicable
|
Emblem Sensor Sensitivity Reduction Mode Transition Frequency (Power Saving)
|
Number of times emblem sensor changed to sensitivity reduction mode (power saving)*1
|
None, Low, Middle or High
|
None: Never
Low: 1 to 10 times
Middle: 11 to 50 times
High: 51 times or more
|
Not applicable
|
Emblem Sensor Sensitivity Drop Frequency (Disturbance Factor)
|
Number of times emblem sensor sensitivity decreased (wave interference)*1
|
None, Low, Middle or High
|
None: Never
Low: 1 to 10 times
Middle: 11 to 50 times
High: 51 times or more
|
Not applicable
|
Emblem Sensor Sensitivity Drop Frequency (Foreign Matter Adhering)
|
Number of times emblem sensor sensitivity decreased (adherence of foreign matter)*1
|
None, Low, Middle or High
|
None: Never
Low: 1 to 10 times
Middle: 11 to 50 times
High: 51 times or more
|
Not applicable
|
Kick Sensor Connection
|
Status of the kick door control sensor connection*2
|
Without or With
|
Without: kick door control sensor not equipped
With: kick door control sensor equipped
|
-
|
Kick Sensor Detection
|
Status of the kick door control sensor detection*2
|
OFF or ON
|
OFF: Kick door control sensor not detecting a foot
ON: Kick door control sensor detecting a foot
|
-
|
Kick Sensor Error
|
Status of the kick door control sensor error*2
|
Normal or Error
|
Normal: Kick door control sensor is normal
Error: Kick door control sensor is abnormal
|
-
|
Kick Sensor Function
|
Status of the hands free power back door function*2
|
OFF or ON
|
Current customize setting displayed
|
-
|
#Codes
|
Number of DTCs
|
Min.: 0, Max.: 255
|
Number of DTCs will be displayed
|
-
|