Last Modified: 01-30-2024 |
6.11:8.1.0 |
Doc ID: RM100000001FW6V |
Model Year Start: 2019 |
Model: RAV4 |
Prod Date Range: [11/2018 - 08/2020] |
Title: DOOR LOCK: POWER DOOR LOCK CONTROL SYSTEM: ON-VEHICLE INSPECTION; 2019 - 2020 MY RAV4 RAV4 HV [11/2018 - 08/2020] |
ON-VEHICLE INSPECTION
PROCEDURE
1. CHECK DOOR CONTROL BATTERY OPERATION (w/ Door Control Battery)
NOTICE:
After performing the following inspection, perform Initialization.
Click here
HINT:
-
After the ignition switch is turned off, the door control battery is discharged in at most 30 minutes. The discharge time may be shortened depending on the amount of door control battery charge.
-
After the ignition switch is turned ON, the door control battery is charged in at most 90 minutes. The charging time may be shortened depending on the amount of door control battery charge.
(a) Check that all of the doors are locked.
(b) Remove the D/L fuse from the instrument panel junction block assembly.
(c) Connect the Techstream to the DLC3.
(d) Turn the ignition switch to ON.
(e) Turn the Techstream on.
(f) Enter the following menus: Body Electrical / Main Body / Active Test.
(g) Perform the Active Test according to the display on the Techstream.
Body Electrical > Main Body > Active Test
Tester Display
|
Measurement Item
|
Control Range
|
Diagnostic Note
|
Shock Detection Unlock
|
Operate door lock motor
|
UNLOCK/LOCK
|
-
|
(h) Remove the ECU-ACC fuse and ECU-IG1 NO. 4 fuse from the instrument panel junction block assembly.
(i) Remove the ECU-DCC NO. 2 fuse from the instrument panel junction block assembly.
(j) Within 20 seconds of removing the ECU-DCC NO. 2 fuse, set the Active Test item "Shock Detection Unlock" to "ON".
Body Electrical > Main Body > Active Test
Tester Display
|
Shock Detection Unlock
|
(k) Check that all the doors unlock.
OK:
All the doors unlock.
If the door lock does not operate properly, refer to How to Proceed with Troubleshooting.
Click here
|