Last Modified: 01-30-2024 |
6.11:8.1.0 |
Doc ID: RM100000001G219 |
Model Year Start: 2019 |
Model: RAV4 HV |
Prod Date Range: [11/2018 -
] |
Title: THEFT DETERRENT / KEYLESS ENTRY: SMART KEY SYSTEM (for Start Function, HV Model): Power Source Mode does not Change to ON (ACC); 2019 - 2024 MY RAV4 HV [11/2018 - ] |
Power Source Mode does not Change to ON (ACC)
|
DESCRIPTION
If the power switch is pressed with the electrical key transmitter sub-assembly in the cabin, the certification ECU (smart key ECU assembly) receives a signal and changes the power source mode.
Related Data List and Active Test Items
Problem Symptom
|
Data List and Active Test
|
Power source mode does not change to on (ACC) but does change to on (IG)
|
Power Source Control
-
Power Supply Condition
-
ACC Relay Monitor
|
HINT:
Use this procedure to troubleshoot the malfunction that ACC mode of all the ECUs is not available.
When ACC mode of some ECUs is not available, check the ACC power source circuit related to the malfunctioning ECUs.
WIRING DIAGRAM
CAUTION / NOTICE / HINT
PROCEDURE
(a) Connect the Techstream to the DLC3.
(b) Turn the power switch on (IG).
(c) Turn the Techstream on.
(d) Enter the following menus: Body Electrical / Smart Key, Power Source Control / Trouble Codes.
(e) Check for DTCs.
Body Electrical > Smart Key > Trouble Codes
Body Electrical > Power Source Control > Trouble Codes
Result
|
Proceed to
|
DTCs are not output
|
A
|
Smart key system (for Start Function) DTCs are output
|
B
|
A
|
|
|
2.
|
CHECK HARNESS AND CONNECTOR (INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY - POWER SUPPLY)
|
(a) Disconnect the instrument panel junction block assembly connectors.
|
|
*a
|
Front view of wire harness connector
(to Instrument Panel Junction Block Assembly)
|
|
|
(b) Measure the voltage according to the value(s) in the table below.
Standard Voltage:
Tester Connection
|
Condition
|
Specified Condition
|
4K-1 - Body ground
|
Always
|
11 to 14 V
|
NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR
|
OK
|
|
|
3.
|
INSPECT INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY
|
*a
|
Component without harness connected
(Instrument Panel Junction Block Assembly)
|
-
|
-
|
(a) Remove the instrument panel junction block assembly.
Click here
(b) Remove the main body ECU (multiplex network body ECU) from the instrument panel junction block assembly.
(c) Connect a positive (+) lead from the auxiliary battery to terminal 4A-30.
(d) Connect a negative (-) lead from the auxiliary battery to terminal 4D-3.
(e) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
|
Condition
|
Specified Condition
|
4K-1 - 4A-40
|
Always
|
Below 1 Ω
|
|