Engine Speed
|
Engine speed
|
Min.: 0 rpm, Max.: 16383 rpm
|
Engine stopped:
0 rpm
While engine running at a constant speed:
No significant fluctuation
|
-
|
Vehicle Speed
|
Vehicle speed
|
Min.: 0 km/h (0 mph), Max.: 255 km/h (158 mph)
|
Vehicle stopped:
0 km/h (0 mph)
While driving at a constant speed:
No significant fluctuation
|
-
|
Engine Run Time
|
Elapsed time after starting engine
|
Min.: 0 sec, Max.: 65535 sec
|
-
|
Elapsed time from initial engine start until the ignition switch is turned off.
|
Warmup Cycle Cleared DTC
|
Warmup cycles after DTCs cleared
|
Min.: 0, Max.: 255
|
-
|
-
|
Distance from DTC Cleared
|
Distance driven after DTCs cleared
|
Min.: 0 km (0 mile), Max.: 65535 km (40723 mile)
|
-
|
-
|
Battery Voltage
|
Auxiliary battery voltage
|
Min.: 0.00 V, Max.: 16.00 V
|
11 to 15 V: Ignition switch ON
|
When ignition switch ON (READY): approx. 12.5 to 15.0 V. When ignition switch ON: same as auxiliary battery voltage (approx. 12 V).
If the voltage becomes 11 V or less when the ignition switch is ON (READY), the hybrid vehicle control ECU assembly stores inverter with converter assembly DTCs.
If the voltage becomes 9.5 V or less, the ignition switch will not be able to be turned to ON (READY).
|
Ambient Temperature
|
Ambient air temperature
|
Min.: -40°C (-40°F), Max.: 215°C (419°F)
|
Ignition switch ON:
Same as ambient air temperature
|
-
|
Time after DTC Cleared
|
Time after DTCs cleared
|
Min.: 0 min, Max.: 65535 min
|
-
|
-
|
Hybrid/EV Battery System Voltage
|
HV battery voltage
|
Min.: 0 V, Max.: 510 V
|
Ignition switch ON (READY):
150 to 300 V
|
-
|
Hybrid/EV Battery System Current
|
HV battery current
|
Min.: -3276.8 A, Max.: 3276.7 A
|
Ignition switch ON:
-4 to 4 A
|
-
|
Motor Revolution
|
Motor (MG2) speed (detected by resolver sensor)
|
Min.: -20000 rpm, Max.: 20000 rpm
|
While driving:
Varies depending on vehicle speed
|
Motor (MG2) speed changes in proportion to vehicle speed.
Motor (MG2) speed is not influenced by accelerator pedal opening angle, engine speed or generator (MG1) speed.
|
Motor Torque
|
Motor (MG2) torque value
|
Min.: -500 Nm, Max.: 500 Nm
|
While driving:
Varies depending on vehicle operating conditions
|
-
|
Motor Control Mode
|
Motor control mode
|
Min.: 0, Max.: 65535
|
-
|
-
|
Generator Revolution
|
Generator (MG1) speed (detected by resolver sensor)
|
Min.: -20000 rpm, Max.: 20000 rpm
|
During charge or discharge:
Varies depending on vehicle operating conditions
|
Generator (MG1) speed is set to obtain requested target engine speed
|
Generator Torque
|
Generator (MG1) torque value
|
Min.: -500 Nm, Max.: 500 Nm
|
During charge or discharge:
Varies depending on vehicle operating conditions
|
-
|
Generator Control Mode
|
Generator control mode
|
Min.: 0, Max.: 65535
|
-
|
-
|
VL Voltage
|
High voltage before it is boosted
|
Min.: 0.0 V, Max.: 500.0 V
|
Ignition switch ON (READY):
Practically the same as the HV battery voltage
|
-
|
VH Voltage
|
High voltage after it is boosted
|
Min.: 0.0 V, Max.: 1000.0 V
|
Engine revving up with shift lever in P:
After boosted voltage to below 650 V
|
-
|
Boosting Converter PWM Duty
|
Boost converter PWM duty
|
Min.: 0 %, Max.: 100 %
|
-
|
-
|
Boosting Converter Control Mode
|
Boost converter control mode
|
Min.: 0, Max.: 255
|
-
|
-
|
Short Wave Highest Value
|
Waveform voltage in abnormal insulation detection circuit in battery voltage sensor
|
Min.: 0.00 V, Max.: 4.98 V
|
-
|
-
|
Fail Safe Mode
|
Fail safe mode
|
Min.: -128, Max.: 127
|
-
|
-
|
Accelerator Position
|
Accelerator position
|
Min.: 0.0 %, Max.: 100.0 %
|
Accelerator pedal depressed:
Changes with accelerator pedal pressure
|
-
|
WIN Control Limit Power
|
Power flowing to HV battery (Charging)
(detected at battery voltage sensor)
|
Min.: -327.68 kW, Max.: 327.67 kW
|
-38.76 kW or more
|
-
|
WOUT Control Limit Power
|
Power flowing from HV battery (Discharging)
(detected at battery voltage sensor)
|
Min.: -327.68 kW, Max.: 327.67 kW
|
25.50 kW or less
|
-
|
Rear Motor Resolver After Offset
|
Rear motor resolver after offset
|
Min.: 0.000 deg, Max.: 358.593 deg
|
-
|
-
|
Rear Motor Revolution
|
Rear motor (MGR) speed (detected by resolver sensor)
|
Min.: -32768 rpm, Max.: 32767 rpm
|
While driving:
Varies depending on vehicle operating conditions
|
-
|
Rear Motor Torque
|
Rear motor (MGR) torque value
|
Min.: -4096.000 Nm, Max.: 4095.875 Nm
|
While driving:
Varies depending on vehicle operating conditions
|
-
|
Rear Motor Control Mode
|
Rear motor control mode
|
Min.: 0, Max.: 65535
|
-
|
-
|
Rear Motor Carrier Frequency
|
Rear motor carrier frequency
|
Min.: 0, Max.: 255
|
-
|
-
|
Rear Motor Inverter Shut Down Signal
|
Rear motor inverter shutdown signal
|
Min.: 0, Max.: 255
|
-
|
-
|
Rear Motor Inverter Temperature
|
Rear motor inverter temperature
|
Min.: 0°C (32°F), Max.: 150°C (302°F)
|
Vehicle left for 1 day at an ambient temperature of 25°C (77°F):
8 to 35°C (46.4 to 95°F)
While driving with an ambient temperature of 25°C (77°F):
25 to 120°C (77 to 248°F)
|
-
|
Rear Motor Temperature
|
Rear motor (MGR) temperature
|
Min.: -40°C (-40°F), Max.: 215°C (419°F)
|
Vehicle left for 1 day at an ambient temperature of 25°C (77°F):
25°C (77°F)
Changes according to vehicle condition and ambient temperature
|
-
|
Rear Motor Inverter Temperature Duty
|
Rear motor inverter temperature duty (CPU input data)
|
Min.: 0.0 %, Max.: 6553.5 %
|
-
|
-
|
Emergency Shutdown Signal
|
Inverter emergency shutdown
|
ON or OFF
|
Inverter emergency shutdown:
ON
Normal:
OFF
|
-
|
Ready ON Status
|
State of system (READY)
|
ON or OFF
|
Ignition switch ON (READY):
ON
|
-
|
SMR Status
|
System main relay status
|
ON or OFF
|
Ignition switch ON (READY):
ON
|
-
|
Generator Inverter High Current(GFINV)
|
Generator (MG1) inverter high current
|
ON or OFF
|
Normal:
OFF
|
-
|
Generator Inverter Shut Down Status
|
Generator (MG1) inverter shutdown status
|
ON or OFF
|
Generator inverter shutdown:
ON
Normal:
OFF
|
-
|
Motor Inverter High Current(MFINV)
|
Motor inverter high current
|
ON or OFF
|
Normal:
OFF
|
-
|
Motor Inverter Shut Down Status
|
Motor inverter shutdown status
|
ON or OFF
|
Motor inverter shutdown:
ON
Normal:
OFF
|
-
|
Boosting Converter Input High Voltage
|
Boost converter input high voltage
|
ON or OFF
|
Normal:
OFF
|
-
|
Boosting Converter Input High Current(CFINV)
|
Boost converter input high current
|
ON or OFF
|
Normal:
OFF
|
-
|
Boosting Converter Shut Down Status
|
Boost converter shutdown status
|
ON or OFF
|
Boost converter shutdown:
ON
Normal:
OFF
|
-
|
Rear Inverter Input High Current(CFINV)
|
Rear inverter input high current
|
ON or OFF
|
Normal:
OFF
|
-
|
Rear Inverter Shut Down Status
|
Rear inverter shutdown status
|
ON or OFF
|
Rear motor inverter shutdown:
ON
Normal:
OFF
|
-
|
Total Distance Traveled
|
Drive total distance
|
Min.: 0 km (0 mile), Max.: 16777215 km (10425361 mile)
|
-
|
-
|
Total Distance Traveled - Unit
|
Drive total distance unit
|
km or mile
|
-
|
-
|
Rear Motor Resolver Offset Value
|
Rear motor resolver offset value
|
Min.: -250.000 deg, Max.: 249.992 deg
|
-
|
-
|
Rear Motor Resolver Offset Complete Status
|
Rear motor resolver learning complete status
|
ON or OFF
|
Rear motor resolver learning has been completed:
ON
|
-
|
Rear Motor U Current (Lower Resolution)
|
Rear motor U phase current (Lower resolution)
|
Min.: -3276.8 A, Max.: 3276.7 A
|
-
|
-
|
Rear Motor V Current (Lower Resolution)
|
Rear motor V phase current (Lower resolution)
|
Min.: -3276.8 A, Max.: 3276.7 A
|
-
|
-
|
Rear Motor W Current (Lower Resolution)
|
Rear motor W phase current (Lower resolution)
|
Min.: -3276.8 A, Max.: 3276.7 A
|
-
|
-
|