Microcomputer malfunction
|
Motor generator control system
|
P0A1A47
|
Generator Control Module Watchdog / Safety MC Failure
|
P0A1A49
|
Generator Control Module Internal Electronic Failure
|
P0A1B1F
|
Generator Control Module Circuit Intermittent
|
P0A1C49
|
Drive Motor "B" Control Module Internal Electronic Failure
|
P1C2A1C
|
Generator A/D Converter Circuit Circuit Voltage Out of Range
|
P1C2A49
|
Generator A/D Converter Circuit Internal Electronic Failure
|
P1C2B1C
|
Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range
|
P1C2B49
|
Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure
|
P1C2C1C
|
Drive Motor "B" Control Module AD Converter Circuit Voltage Out of Range
|
P1C2C49
|
Drive Motor "B" Control Module AD Converter Internal Electronic Failure
|
P310A83
|
Communication Error from Drive Motor "B" to Drive Motor "A" Value of Signal Protection Calculation Incorrect
|
P310A86
|
Communication Error from Drive Motor "B" to Drive Motor "A" Signal (Some Circuit Quantity, Reported via Serial Data) Invalid
|
P310A87
|
Communication Error from Drive Motor "B" to Drive Motor "A" Missing Message
|
P310B83
|
Communication Error from Drive Motor "A" to Drive Motor "B" Value of Signal Protection Calculation Incorrect
|
P310B86
|
Communication Error from Drive Motor "A" to Drive Motor "B" Signal (Some Circuit Quantity, Reported via Serial Data) Invalid
|
P310B87
|
Communication Error from Drive Motor "A" to Drive Motor "B" Missing Message
|
P313383
|
Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect
|
P313386
|
Communication Error from Generator to Drive Motor "A" Signal Invalid
|
P313387
|
Communication Error from Generator to Drive Motor "A" Missing Message
|
P313483
|
Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect
|
P313486
|
Communication Error from Drive Motor "A" to Generator Signal Invalid
|
P313487
|
Communication Error from Drive Motor "A" to Generator Missing Message
|
P32BF83
|
Lost Communication between Drive Motor "A" and "B" (Drive Motor "A") Value of Signal Protection Calculation Incorrect
|
P32BF86
|
Lost Communication between Drive Motor "A" and "B" (Drive Motor "A") Signal (Some Circuit Quantity, Reported via Serial Data) Invalid
|
P32BF87
|
Lost Communication between Drive Motor "A" and "B" (Drive Motor "A") Missing Message
|
P32CF83
|
Lost Communication between Drive Motor "A" and "B" (Drive Motor "B") Value of Signal Protection Calculation Incorrect
|
P32CF86
|
Lost Communication between Drive Motor "A" and "B" (Drive Motor "B") Signal (Some Circuit Quantity, Reported via Serial Data) Invalid
|
P32CF87
|
Lost Communication between Drive Motor "A" and "B" (Drive Motor "B") Missing Message
|
Hybrid control system
|
P0A1B49
|
Drive Motor "A" Control Module Internal Electronic Failure
|
Power source circuit malfunction
|
Motor generator control system
|
P06B01C
|
Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range
|
P06D61C
|
Generator Control Module Offset Power Circuit Voltage Out of Range
|
Communication malfunction
|
Motor generator control system
|
P312487
|
Lost Communication between Drive Motor "A" and HV ECU Missing Message
|
Hybrid control system
|
P312387
|
Lost Communication with Drive Motor Control Module "A" from Hybrid/EV Control Module Missing Message
|
Sensor and actuator circuit malfunction
|
Motor generator control system
|
P0A3F16
|
Drive Motor "A" Position Sensor Circuit Voltage Below Threshold
|
P0A3F21
|
Drive Motor "A" Position Sensor Signal Amplitude < Minimum
|
P0A3F22
|
Drive Motor "A" Position Sensor Signal Amplitude > Maximum
|
P0A4516
|
Drive Motor "B" Position Sensor Circuit Voltage Below Threshold
|
P0A4521
|
Drive Motor "B" Position Sensor Signal Amplitude < Minimum
|
P0A4522
|
Drive Motor "B" Position Sensor Signal Amplitude > Maximum
|
P0A4B16
|
Generator Position Sensor Circuit Voltage Below Threshold
|
P0A4B21
|
Generator Position Sensor Signal Amplitude < Minimum
|
P0A4B22
|
Generator Position Sensor Signal Amplitude > Maximum
|
P0A6012
|
Drive Motor "A" Phase V Current (High Resolution) Circuit Short to Battery
|
P0A6014
|
Drive Motor "A" Phase V Current (High Resolution) Circuit Short to Ground or Open
|
P0A601C
|
Drive Motor "A" Phase V Current (High Resolution) Circuit Voltage Out of Range
|
P0A6312
|
Drive Motor "A" Phase W Current (High Resolution) Circuit Short to Battery
|
P0A6314
|
Drive Motor "A" Phase W Current (High Resolution) Circuit Short to Ground or Open
|
P0A631C
|
Drive Motor "A" Phase W Current (High Resolution) Circuit Voltage Out of Range
|
P0BE512
|
Drive Motor "A" Phase U Current Sensor Circuit Short to Battery
|
P0BE514
|
Drive Motor "A" Phase U Current Sensor Circuit Short to Ground or Open
|
P0BE528
|
Drive Motor "A" Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure
|
P0BE912
|
Drive Motor "A" Phase V Current Sensor Circuit Short to Battery
|
P0BE914
|
Drive Motor "A" Phase V Current Sensor Circuit Short to Ground or Open
|
P0BE928
|
Drive Motor "A" Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure
|
P0BED12
|
Drive Motor "A" Phase W Current Sensor Circuit Short to Battery
|
P0BED14
|
Drive Motor "A" Phase W Current Sensor Circuit Short to Ground or Open
|
P0BED28
|
Drive Motor "A" Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure
|
P0BF112
|
Drive Motor "B" Phase U Current Sensor Circuit Short to Battery
|
P0BF114
|
Drive Motor "B" Phase U Current Sensor Circuit Short to Ground or Open
|
P0BF128
|
Drive Motor "B" Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure
|
P0BF512
|
Drive Motor "B" Phase V Current Sensor Circuit Short to Battery
|
P0BF514
|
Drive Motor "B" Phase V Current Sensor Circuit Short to Ground or Open
|
P0BF528
|
Drive Motor "B" Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure
|
P0BF912
|
Drive Motor "B" Phase W Current Sensor Circuit Short to Battery
|
P0BF914
|
Drive Motor "B" Phase W Current Sensor Circuit Short to Ground or Open
|
P0BF928
|
Drive Motor "B" Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure
|
P0BFD62
|
Drive Motor "A" Phase U-V-W Current Sensor Signal Compare Failure
|
P0BFE62
|
Drive Motor "B" Phase U-V-W Current Sensor Signal Compare Failure
|
P0C5013
|
Drive Motor "A" Position Sensor Circuit "A" Circuit Open
|
P0C5016
|
Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Below Threshold
|
P0C5017
|
Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Above Threshold
|
P0C5513
|
Drive Motor "B" Position Sensor Circuit "A" Circuit Open
|
P0C5516
|
Drive Motor "B" Position Sensor Circuit "A" Circuit Voltage Below Threshold
|
P0C5517
|
Drive Motor "B" Position Sensor Circuit "A" Circuit Voltage Above Threshold
|
P0C5A13
|
Drive Motor "A" Position Sensor Circuit "B" Circuit Open
|
P0C5A16
|
Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Below Threshold
|
P0C5A17
|
Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Above Threshold
|
P0C5F13
|
Drive Motor "B" Position Sensor Circuit "B" Circuit Open
|
P0C5F16
|
Drive Motor "B" Position Sensor Circuit "B" Circuit Voltage Below Threshold
|
P0C5F17
|
Drive Motor "B" Position Sensor Circuit "B" Circuit Voltage Above Threshold
|
P0C6413
|
Generator Position Sensor Circuit "A" Circuit Open
|
P0C6416
|
Generator Position Sensor Circuit "A" Circuit Voltage Below Threshold
|
P0C6417
|
Generator Position Sensor Circuit "A" Circuit Voltage Above Threshold
|
P0C6913
|
Generator Position Sensor Circuit "B" Circuit Open
|
P0C6916
|
Generator Position Sensor Circuit "B" Circuit Voltage Below Threshold
|
P0C6917
|
Generator Position Sensor Circuit "B" Circuit Voltage Above Threshold
|
P0D2D16
|
Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Voltage Below Threshold
|
P0D2D17
|
Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Voltage Above Threshold
|
P0DFA62
|
Generator Phase U-V-W Current Sensor Signal Compare Failure
|
P0E0012
|
Generator Phase U Current Sensor Circuit Short to Battery
|
P0E0014
|
Generator Phase U Current Sensor Circuit Short to Ground or Open
|
P0E0028
|
Generator Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure
|
P0E0412
|
Generator Phase V Current Sensor Circuit Short to Battery
|
P0E0414
|
Generator Phase V Current Sensor Circuit Short to Ground or Open
|
P0E0428
|
Generator Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure
|
P0E0812
|
Generator Phase W Current Sensor Circuit Short to Battery
|
P0E0814
|
Generator Phase W Current Sensor Circuit Short to Ground or Open
|
P0E0828
|
Generator Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure
|
P0E3116
|
DC/DC Converter Voltage Sensor "A" (VL) Circuit Voltage Below Threshold
|
P0E3117
|
DC/DC Converter Voltage Sensor "A" (VL) Circuit Voltage Above Threshold
|
P0E5111
|
DC/DC Converter Current Sensor Circuit Short to Ground
|
P0E5115
|
DC/DC Converter Current Sensor Circuit Short to Battery or Open
|
P1CAC49
|
Generator Position Sensor Internal Electronic Failure
|
P1CAD49
|
Drive Motor "A" Position Sensor Internal Electronic Failure
|
P1CAE49
|
Drive Motor "B" Position Sensor Internal Electronic Failure
|
P1CAF38
|
Generator Position Sensor REF Signal Cycle Malfunction Signal Frequency Incorrect
|
P1CB038
|
Drive Motor "A" Position Sensor REF Signal Frequency Incorrect
|
P1CB138
|
Drive Motor "B" Position Sensor REF Signal Frequency Incorrect
|
Rear motor generator control system
|
P0A6912
|
Drive Motor "B" Phase V Current(High Resolution) Circuit Short to Battery
|
P0A6914
|
Drive Motor "B" Phase V Current(High Resolution) Circuit Short to Ground or Open
|
P0A691C
|
Drive Motor "B" Phase V Current(High Resolution) Circuit Voltage Out of Range
|
P0A6C12
|
Drive Motor "B" Phase W Current(High Resolution) Circuit Short to Battery
|
P0A6C14
|
Drive Motor "B" Phase W Current(High Resolution) Circuit Short to Ground or Open
|
P0A6C1C
|
Drive Motor "B" Phase W Current(High Resolution) Circuit Voltage Out of Range
|
Hybrid control system
|
P0C7600
|
Hybrid/EV Battery System Discharge Time Too Long
|
P0D2D1C
|
Drive Motor "A" Inverter Voltage Sensor Voltage Out of Range
|
P0E311C
|
Boosting Converter Voltage Sensor "A" Voltage Out of Range
|
System Malfunction
|
Motor generator control system
|
P0A9000
|
Drive Motor "A" Performance
|
P0A9100
|
Drive Motor "B" Performance
|
P0A9200
|
Hybrid Generator Performance
|
P0BFF1D
|
Drive Motor "A" Circuit Current Out of Range
|
P0C021D
|
Drive Motor "B" System Circuit Current Out of Range
|
P0C1900
|
Drive Motor "A" Execution Torque Performance
|
P0C1A00
|
Drive Motor "B" Execution Torque Performance
|
P0CA300
|
DC/DC Converter Step Up Voltage Performance
|
P0E7100
|
Generator Execution Torque Performance
|
P1CA51D
|
Hybrid Generator Circuit Current Out of Range
|
Hybrid control system
|
P0AA649
|
Hybrid/EV Battery Voltage System Isolation Internal Electronic Failure
|
P1C8049
|
Hybrid/EV Battery Voltage System Isolation (Rear Motor Area) Internal Electronic Failure
|