                               Microcomputer malfunction 
                            | 
                           
                               Motor generator control system 
                            | 
                           
                               P0A1A47 
                            | 
                           
                               Generator Control Module Watchdog / Safety MC Failure 
                            | 
                        
                        
                           | 
                               P0A1A49 
                            | 
                           
                               Generator Control Module Internal Electronic Failure 
                            | 
                        
                        
                           | 
                               P0A1B1F 
                            | 
                           
                               Generator Control Module Circuit Intermittent 
                            | 
                        
                        
                           | 
                               P0A1C49 
                            | 
                           
                               Drive Motor "B" Control Module Internal Electronic Failure 
                            | 
                        
                        
                           | 
                               P1C2A1C 
                            | 
                           
                               Generator A/D Converter Circuit Circuit Voltage Out of Range 
                            | 
                        
                        
                           | 
                               P1C2A49 
                            | 
                           
                               Generator A/D Converter Circuit Internal Electronic Failure 
                            | 
                        
                        
                           | 
                               P1C2B1C 
                            | 
                           
                               Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range 
                            | 
                        
                        
                           | 
                               P1C2B49 
                            | 
                           
                               Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure 
                            | 
                        
                        
                           | 
                               P1C2C1C 
                            | 
                           
                               Drive Motor "B" Control Module AD Converter Circuit Voltage Out of Range 
                            | 
                        
                        
                           | 
                               P1C2C49 
                            | 
                           
                               Drive Motor "B" Control Module AD Converter Internal Electronic Failure 
                            | 
                        
                        
                           | 
                               P310A83 
                            | 
                           
                               Communication Error from Drive Motor "B" to Drive Motor "A" Value of Signal Protection Calculation Incorrect 
                            | 
                        
                        
                           | 
                               P310A86 
                            | 
                           
                               Communication Error from Drive Motor "B" to Drive Motor "A" Signal (Some Circuit Quantity, Reported via Serial Data) Invalid 
                            | 
                        
                        
                           | 
                               P310A87 
                            | 
                           
                               Communication Error from Drive Motor "B" to Drive Motor "A" Missing Message 
                            | 
                        
                        
                           | 
                               P310B83 
                            | 
                           
                               Communication Error from Drive Motor "A" to Drive Motor "B" Value of Signal Protection Calculation Incorrect 
                            | 
                        
                        
                           | 
                               P310B86 
                            | 
                           
                               Communication Error from Drive Motor "A" to Drive Motor "B" Signal (Some Circuit Quantity, Reported via Serial Data) Invalid 
                            | 
                        
                        
                           | 
                               P310B87 
                            | 
                           
                               Communication Error from Drive Motor "A" to Drive Motor "B" Missing Message 
                            | 
                        
                        
                           | 
                               P313383 
                            | 
                           
                               Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect 
                            | 
                        
                        
                           | 
                               P313386 
                            | 
                           
                               Communication Error from Generator to Drive Motor "A" Signal Invalid 
                            | 
                        
                        
                           | 
                               P313387 
                            | 
                           
                               Communication Error from Generator to Drive Motor "A" Missing Message 
                            | 
                        
                        
                           | 
                               P313483 
                            | 
                           
                               Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect 
                            | 
                        
                        
                           | 
                               P313486 
                            | 
                           
                               Communication Error from Drive Motor "A" to Generator Signal Invalid 
                            | 
                        
                        
                           | 
                               P313487 
                            | 
                           
                               Communication Error from Drive Motor "A" to Generator Missing Message 
                            | 
                        
                        
                           | 
                               P32BF83 
                            | 
                           
                               Lost Communication between Drive Motor "A" and "B" (Drive Motor "A") Value of Signal Protection Calculation Incorrect 
                            | 
                        
                        
                           | 
                               P32BF86 
                            | 
                           
                               Lost Communication between Drive Motor "A" and "B" (Drive Motor "A") Signal (Some Circuit Quantity, Reported via Serial Data) Invalid 
                            | 
                        
                        
                           | 
                               P32BF87 
                            | 
                           
                               Lost Communication between Drive Motor "A" and "B" (Drive Motor "A") Missing Message 
                            | 
                        
                        
                           | 
                               P32CF83 
                            | 
                           
                               Lost Communication between Drive Motor "A" and "B" (Drive Motor "B") Value of Signal Protection Calculation Incorrect 
                            | 
                        
                        
                           | 
                               P32CF86 
                            | 
                           
                               Lost Communication between Drive Motor "A" and "B" (Drive Motor "B") Signal (Some Circuit Quantity, Reported via Serial Data) Invalid 
                            | 
                        
                        
                           | 
                               P32CF87 
                            | 
                           
                               Lost Communication between Drive Motor "A" and "B" (Drive Motor "B") Missing Message 
                            | 
                        
                        
                           | 
                               Hybrid control system 
                            | 
                           
                               P0A1B49 
                            | 
                           
                               Drive Motor "A" Control Module Internal Electronic Failure 
                            | 
                        
                        
                           | 
                               Power source circuit malfunction 
                            | 
                           
                               Motor generator control system 
                            | 
                           
                               P06B01C 
                            | 
                           
                               Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range 
                            | 
                        
                        
                           | 
                               P06D61C 
                            | 
                           
                               Generator Control Module Offset Power Circuit Voltage Out of Range 
                            | 
                        
                        
                           | 
                               Communication malfunction 
                            | 
                           
                               Motor generator control system 
                            | 
                           
                               P312487 
                            | 
                           
                               Lost Communication between Drive Motor "A" and HV ECU Missing Message 
                            | 
                        
                        
                           | 
                               Hybrid control system 
                            | 
                           
                               P312387 
                            | 
                           
                               Lost Communication with Drive Motor Control Module "A" from Hybrid/EV Control Module Missing Message 
                            | 
                        
                        
                           | 
                               Sensor and actuator circuit malfunction 
                            | 
                           
                               Motor generator control system 
                            | 
                           
                               P0A3F16 
                            | 
                           
                               Drive Motor "A" Position Sensor Circuit Voltage Below Threshold 
                            | 
                        
                        
                           | 
                               P0A3F21 
                            | 
                           
                               Drive Motor "A" Position Sensor Signal Amplitude < Minimum 
                            | 
                        
                        
                           | 
                               P0A3F22 
                            | 
                           
                               Drive Motor "A" Position Sensor Signal Amplitude > Maximum 
                            | 
                        
                        
                           | 
                               P0A4516 
                            | 
                           
                               Drive Motor "B" Position Sensor Circuit Voltage Below Threshold 
                            | 
                        
                        
                           | 
                               P0A4521 
                            | 
                           
                               Drive Motor "B" Position Sensor Signal Amplitude < Minimum 
                            | 
                        
                        
                           | 
                               P0A4522 
                            | 
                           
                               Drive Motor "B" Position Sensor Signal Amplitude > Maximum 
                            | 
                        
                        
                           | 
                               P0A4B16 
                            | 
                           
                               Generator Position Sensor Circuit Voltage Below Threshold 
                            | 
                        
                        
                           | 
                               P0A4B21 
                            | 
                           
                               Generator Position Sensor Signal Amplitude < Minimum 
                            | 
                        
                        
                           | 
                               P0A4B22 
                            | 
                           
                               Generator Position Sensor Signal Amplitude > Maximum 
                            | 
                        
                        
                           | 
                               P0A6012 
                            | 
                           
                               Drive Motor "A" Phase V Current (High Resolution) Circuit Short to Battery 
                            | 
                        
                        
                           | 
                               P0A6014 
                            | 
                           
                               Drive Motor "A" Phase V Current (High Resolution) Circuit Short to Ground or Open 
                            | 
                        
                        
                           | 
                               P0A601C 
                            | 
                           
                               Drive Motor "A" Phase V Current (High Resolution) Circuit Voltage Out of Range 
                            | 
                        
                        
                           | 
                               P0A6312 
                            | 
                           
                               Drive Motor "A" Phase W Current (High Resolution) Circuit Short to Battery 
                            | 
                        
                        
                           | 
                               P0A6314 
                            | 
                           
                               Drive Motor "A" Phase W Current (High Resolution) Circuit Short to Ground or Open 
                            | 
                        
                        
                           | 
                               P0A631C 
                            | 
                           
                               Drive Motor "A" Phase W Current (High Resolution) Circuit Voltage Out of Range 
                            | 
                        
                        
                           | 
                               P0BE512 
                            | 
                           
                               Drive Motor "A" Phase U Current Sensor Circuit Short to Battery 
                            | 
                        
                        
                           | 
                               P0BE514 
                            | 
                           
                               Drive Motor "A" Phase U Current Sensor Circuit Short to Ground or Open 
                            | 
                        
                        
                           | 
                               P0BE528 
                            | 
                           
                               Drive Motor "A" Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure 
                            | 
                        
                        
                           | 
                               P0BE912 
                            | 
                           
                               Drive Motor "A" Phase V Current Sensor Circuit Short to Battery 
                            | 
                        
                        
                           | 
                               P0BE914 
                            | 
                           
                               Drive Motor "A" Phase V Current Sensor Circuit Short to Ground or Open 
                            | 
                        
                        
                           | 
                               P0BE928 
                            | 
                           
                               Drive Motor "A" Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure 
                            | 
                        
                        
                           | 
                               P0BED12 
                            | 
                           
                               Drive Motor "A" Phase W Current Sensor Circuit Short to Battery 
                            | 
                        
                        
                           | 
                               P0BED14 
                            | 
                           
                               Drive Motor "A" Phase W Current Sensor Circuit Short to Ground or Open 
                            | 
                        
                        
                           | 
                               P0BED28 
                            | 
                           
                               Drive Motor "A" Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure 
                            | 
                        
                        
                           | 
                               P0BF112 
                            | 
                           
                               Drive Motor "B" Phase U Current Sensor Circuit Short to Battery 
                            | 
                        
                        
                           | 
                               P0BF114 
                            | 
                           
                               Drive Motor "B" Phase U Current Sensor Circuit Short to Ground or Open 
                            | 
                        
                        
                           | 
                               P0BF128 
                            | 
                           
                               Drive Motor "B" Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure 
                            | 
                        
                        
                           | 
                               P0BF512 
                            | 
                           
                               Drive Motor "B" Phase V Current Sensor Circuit Short to Battery 
                            | 
                        
                        
                           | 
                               P0BF514 
                            | 
                           
                               Drive Motor "B" Phase V Current Sensor Circuit Short to Ground or Open 
                            | 
                        
                        
                           | 
                               P0BF528 
                            | 
                           
                               Drive Motor "B" Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure 
                            | 
                        
                        
                           | 
                               P0BF912 
                            | 
                           
                               Drive Motor "B" Phase W Current Sensor Circuit Short to Battery 
                            | 
                        
                        
                           | 
                               P0BF914 
                            | 
                           
                               Drive Motor "B" Phase W Current Sensor Circuit Short to Ground or Open 
                            | 
                        
                        
                           | 
                               P0BF928 
                            | 
                           
                               Drive Motor "B" Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure 
                            | 
                        
                        
                           | 
                               P0BFD62 
                            | 
                           
                               Drive Motor "A" Phase U-V-W Current Sensor Signal Compare Failure 
                            | 
                        
                        
                           | 
                               P0BFE62 
                            | 
                           
                               Drive Motor "B" Phase U-V-W Current Sensor Signal Compare Failure 
                            | 
                        
                        
                           | 
                               P0C5013 
                            | 
                           
                               Drive Motor "A" Position Sensor Circuit "A" Circuit Open 
                            | 
                        
                        
                           | 
                               P0C5016 
                            | 
                           
                               Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Below Threshold 
                            | 
                        
                        
                           | 
                               P0C5017 
                            | 
                           
                               Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Above Threshold 
                            | 
                        
                        
                           | 
                               P0C5513 
                            | 
                           
                               Drive Motor "B" Position Sensor Circuit "A" Circuit Open 
                            | 
                        
                        
                           | 
                               P0C5516 
                            | 
                           
                               Drive Motor "B" Position Sensor Circuit "A" Circuit Voltage Below Threshold 
                            | 
                        
                        
                           | 
                               P0C5517 
                            | 
                           
                               Drive Motor "B" Position Sensor Circuit "A" Circuit Voltage Above Threshold 
                            | 
                        
                        
                           | 
                               P0C5A13 
                            | 
                           
                               Drive Motor "A" Position Sensor Circuit "B" Circuit Open 
                            | 
                        
                        
                           | 
                               P0C5A16 
                            | 
                           
                               Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Below Threshold 
                            | 
                        
                        
                           | 
                               P0C5A17 
                            | 
                           
                               Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Above Threshold 
                            | 
                        
                        
                           | 
                               P0C5F13 
                            | 
                           
                               Drive Motor "B" Position Sensor Circuit "B" Circuit Open 
                            | 
                        
                        
                           | 
                               P0C5F16 
                            | 
                           
                               Drive Motor "B" Position Sensor Circuit "B" Circuit Voltage Below Threshold 
                            | 
                        
                        
                           | 
                               P0C5F17 
                            | 
                           
                               Drive Motor "B" Position Sensor Circuit "B" Circuit Voltage Above Threshold 
                            | 
                        
                        
                           | 
                               P0C6413 
                            | 
                           
                               Generator Position Sensor Circuit "A" Circuit Open 
                            | 
                        
                        
                           | 
                               P0C6416 
                            | 
                           
                               Generator Position Sensor Circuit "A" Circuit Voltage Below Threshold 
                            | 
                        
                        
                           | 
                               P0C6417 
                            | 
                           
                               Generator Position Sensor Circuit "A" Circuit Voltage Above Threshold 
                            | 
                        
                        
                           | 
                               P0C6913 
                            | 
                           
                               Generator Position Sensor Circuit "B" Circuit Open 
                            | 
                        
                        
                           | 
                               P0C6916 
                            | 
                           
                               Generator Position Sensor Circuit "B" Circuit Voltage Below Threshold 
                            | 
                        
                        
                           | 
                               P0C6917 
                            | 
                           
                               Generator Position Sensor Circuit "B" Circuit Voltage Above Threshold 
                            | 
                        
                        
                           | 
                               P0D2D16 
                            | 
                           
                               Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Voltage Below Threshold 
                            | 
                        
                        
                           | 
                               P0D2D17 
                            | 
                           
                               Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Voltage Above Threshold 
                            | 
                        
                        
                           | 
                               P0DFA62 
                            | 
                           
                               Generator Phase U-V-W Current Sensor Signal Compare Failure 
                            | 
                        
                        
                           | 
                               P0E0012 
                            | 
                           
                               Generator Phase U Current Sensor Circuit Short to Battery 
                            | 
                        
                        
                           | 
                               P0E0014 
                            | 
                           
                               Generator Phase U Current Sensor Circuit Short to Ground or Open 
                            | 
                        
                        
                           | 
                               P0E0028 
                            | 
                           
                               Generator Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure 
                            | 
                        
                        
                           | 
                               P0E0412 
                            | 
                           
                               Generator Phase V Current Sensor Circuit Short to Battery 
                            | 
                        
                        
                           | 
                               P0E0414 
                            | 
                           
                               Generator Phase V Current Sensor Circuit Short to Ground or Open 
                            | 
                        
                        
                           | 
                               P0E0428 
                            | 
                           
                               Generator Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure 
                            | 
                        
                        
                           | 
                               P0E0812 
                            | 
                           
                               Generator Phase W Current Sensor Circuit Short to Battery 
                            | 
                        
                        
                           | 
                               P0E0814 
                            | 
                           
                               Generator Phase W Current Sensor Circuit Short to Ground or Open 
                            | 
                        
                        
                           | 
                               P0E0828 
                            | 
                           
                               Generator Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure 
                            | 
                        
                        
                           | 
                               P0E3116 
                            | 
                           
                               DC/DC Converter Voltage Sensor "A" (VL) Circuit Voltage Below Threshold 
                            | 
                        
                        
                           | 
                               P0E3117 
                            | 
                           
                               DC/DC Converter Voltage Sensor "A" (VL) Circuit Voltage Above Threshold 
                            | 
                        
                        
                           | 
                               P0E5111 
                            | 
                           
                               DC/DC Converter Current Sensor Circuit Short to Ground 
                            | 
                        
                        
                           | 
                               P0E5115 
                            | 
                           
                               DC/DC Converter Current Sensor Circuit Short to Battery or Open 
                            | 
                        
                        
                           | 
                               P1CAC49 
                            | 
                           
                               Generator Position Sensor Internal Electronic Failure 
                            | 
                        
                        
                           | 
                               P1CAD49 
                            | 
                           
                               Drive Motor "A" Position Sensor Internal Electronic Failure 
                            | 
                        
                        
                           | 
                               P1CAE49 
                            | 
                           
                               Drive Motor "B" Position Sensor Internal Electronic Failure 
                            | 
                        
                        
                           | 
                               P1CAF38 
                            | 
                           
                               Generator Position Sensor REF Signal Cycle Malfunction Signal Frequency Incorrect 
                            | 
                        
                        
                           | 
                               P1CB038 
                            | 
                           
                               Drive Motor "A" Position Sensor REF Signal Frequency Incorrect 
                            | 
                        
                        
                           | 
                               P1CB138 
                            | 
                           
                               Drive Motor "B" Position Sensor REF Signal Frequency Incorrect 
                            | 
                        
                        
                           | 
                               Rear motor generator control system 
                            | 
                           
                               P0A6912 
                            | 
                           
                               Drive Motor "B" Phase V Current(High Resolution) Circuit Short to Battery 
                            | 
                        
                        
                           | 
                               P0A6914 
                            | 
                           
                               Drive Motor "B" Phase V Current(High Resolution) Circuit Short to Ground or Open 
                            | 
                        
                        
                           | 
                               P0A691C 
                            | 
                           
                               Drive Motor "B" Phase V Current(High Resolution) Circuit Voltage Out of Range 
                            | 
                        
                        
                           | 
                               P0A6C12 
                            | 
                           
                               Drive Motor "B" Phase W Current(High Resolution) Circuit Short to Battery 
                            | 
                        
                        
                           | 
                               P0A6C14 
                            | 
                           
                               Drive Motor "B" Phase W Current(High Resolution) Circuit Short to Ground or Open 
                            | 
                        
                        
                           | 
                               P0A6C1C 
                            | 
                           
                               Drive Motor "B" Phase W Current(High Resolution) Circuit Voltage Out of Range 
                            | 
                        
                        
                           | 
                               Hybrid control system 
                            | 
                           
                               P0C7600 
                            | 
                           
                               Hybrid/EV Battery System Discharge Time Too Long 
                            | 
                        
                        
                           | 
                               P0D2D1C 
                            | 
                           
                               Drive Motor "A" Inverter Voltage Sensor Voltage Out of Range 
                            | 
                        
                        
                           | 
                               P0E311C 
                            | 
                           
                               Boosting Converter Voltage Sensor "A" Voltage Out of Range 
                            | 
                        
                        
                           | 
                               System Malfunction 
                            | 
                           
                               Motor generator control system 
                            | 
                           
                               P0A9000 
                            | 
                           
                               Drive Motor "A" Performance 
                            | 
                        
                        
                           | 
                               P0A9100 
                            | 
                           
                               Drive Motor "B" Performance 
                            | 
                        
                        
                           | 
                               P0A9200 
                            | 
                           
                               Hybrid Generator Performance 
                            | 
                        
                        
                           | 
                               P0BFF1D 
                            | 
                           
                               Drive Motor "A" Circuit Current Out of Range 
                            | 
                        
                        
                           | 
                               P0C021D 
                            | 
                           
                               Drive Motor "B" System Circuit Current Out of Range 
                            | 
                        
                        
                           | 
                               P0C1900 
                            | 
                           
                               Drive Motor "A" Execution Torque Performance 
                            | 
                        
                        
                           | 
                               P0C1A00 
                            | 
                           
                               Drive Motor "B" Execution Torque Performance 
                            | 
                        
                        
                           | 
                               P0CA300 
                            | 
                           
                               DC/DC Converter Step Up Voltage Performance 
                            | 
                        
                        
                           | 
                               P0E7100 
                            | 
                           
                               Generator Execution Torque Performance 
                            | 
                        
                        
                           | 
                               P1CA51D 
                            | 
                           
                               Hybrid Generator Circuit Current Out of Range 
                            | 
                        
                        
                           | 
                               Hybrid control system 
                            | 
                           
                               P0AA649 
                            | 
                           
                               Hybrid/EV Battery Voltage System Isolation Internal Electronic Failure 
                            | 
                        
                        
                           | 
                               P1C8049 
                            | 
                           
                               Hybrid/EV Battery Voltage System Isolation (Rear Motor Area) Internal Electronic Failure 
                            |