Last Modified: 01-30-2024 |
6.11:8.1.0 |
Doc ID: RM100000001H3L1 |
Model Year Start: 2019 |
Model: RAV4 HV |
Prod Date Range: [02/2019 -
] |
Title: HYBRID / BATTERY CONTROL: HYBRID CONTROL SYSTEM (for AWD with NICKEL METAL HYDRIDE BATTERY): Generator High-voltage Circuit; 2019 - 2024 MY RAV4 HV [02/2019 - ] |
Generator High-voltage Circuit
|
DESCRIPTION
The cause of this malfunction may be the generator high-voltage circuit.
Check the generator internal resistance and the connection condition of the high-voltage line between the inverter and generator to check whether there is an open or short circuit.
Related Parts Check
Area
|
Inspection
|
Motor cable (for MG1) connection check
|
Check for the connection condition of the cable from the inverter to the generator.
|
Generator or motor cable (for MG1)
|
Check the generator (including cable) internal resistance and the insulation resistance with body ground to check for an open or short circuit.
|
WIRING DIAGRAM
CAUTION / NOTICE / HINT
This diagnostic procedure is referenced to in the diagnostic procedure of several DTCs.
If the result of this diagnostic procedure is normal, proceed as directed in the procedure for the DTC.
NOTICE:
After turning the ignition switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.
Click here
PROCEDURE
1.
|
CHECK INVERTER WITH CONVERTER ASSEMBLY (MOTOR CABLE CONNECTION CONDITION)
|
CAUTION:
Be sure to wear insulated gloves.
(a) Check that the service plug grip is not installed.
NOTICE:
After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
(b) Remove the inverter cover from the inverter with converter assembly.
(c) Check that the bolts for the motor cable are tightened to the specified torque, the generator cable is connected securely, and there are no contact problems.
Specified Condition:
T = 8.0 N*m (82 kgf*cm, 71 in.*lbf)
|
|
(d) Disconnect the motor cable from the inverter with converter assembly.
(e) Check for arc marks at the terminals for the motor cable.
Result
|
Proceed to
|
The terminals are connected securely and there are no contact problems.
|
There are no arc marks.
|
A
|
The terminals are not connected securely and there is a contact problem.
|
There are arc marks.
|
B
|
The terminals are not connected securely and there is a contact problem.
|
There are no arc marks.
|
C
|
The terminals are connected securely and there are no contact problems.
|
There are arc marks.
|
B
|
(f) Reconnect the motor cable.
(g) Reinstall the inverter cover.
B |
|
REPLACE MALFUNCTIONING PARTS
|
C |
|
CONNECT SECURELY
|
A
|
|
|
2.
|
CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (GENERATOR (MG1))
|
CAUTION:
Be sure to wear insulated gloves.
(a) Check that the service plug grip is not installed.
NOTICE:
After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
(b) Remove the inverter cover from the inverter with converter assembly.
(c) Disconnect the motor cable from the inverter with converter assembly.
(d) Using a milliohmmeter, measure the resistance according to the value(s) in the table below.
HINT:
If the generator (MG1) temperature is high, the resistance will vary greatly from the specification. Therefore, measure the resistance at least 8 hours after the vehicle is stopped.
Standard Resistance:
Tester Connection
|
Condition
|
Specified Condition
|
d2-4 (W) - d2-5 (U)
|
Ignition switch off
|
49.3 to 54.4 mΩ
|
d2-5 (U) - d2-6 (V)
|
Ignition switch off
|
49.3 to 54.4 mΩ
|
d2-6 (V) - d2-4 (W)
|
Ignition switch off
|
49.3 to 54.4 mΩ
|
HINT:
To correct the variation of the measured resistance due to temperature, use the following formula to calculate the resistance at 20°C (68°F).
R20 = Rt / {1 + 0.00393 X (T - 20)}
The calculation is based on the following:
R20: Resistance at 20°C (68°F) (mΩ)
Rt: Measured resistance (mΩ)
T: Temperature when the resistance is measured (°C)
|
|
*1
|
Shield Ground
|
*a
|
Motor Cable (for MG1)
(Inverter with Converter Assembly Side)
|
|
|
(e) Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.
NOTICE:
Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.
Standard Resistance:
Tester Connection
|
Condition
|
Specified Condition
|
d2-4 (W) - Body ground and shield ground
|
Ignition switch off
|
10 MΩ or higher
|
d2-5 (U) - Body ground and shield ground
|
Ignition switch off
|
10 MΩ or higher
|
d2-6 (V) - Body ground and shield ground
|
Ignition switch off
|
10 MΩ or higher
|
(f) Reconnect the motor cable.
(g) Reinstall the inverter cover.
OK |
|
GENERATOR HIGH-VOLTAGE CIRCUIT NORMAL (PERFORM NEXT STEP FOR REFERENCED DTC)
|
NG
|
|
|
3.
|
CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (MOTOR CABLE CONNECTION CONDITION)
|
CAUTION:
Be sure to wear insulated gloves.
(a) Check that the service plug grip is not installed.
NOTICE:
After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
(b) Remove the inverter with converter assembly.
(c) Check that the bolts for the motor cable are tightened to the specified torque, the motor cable is connected securely, and there are no contact problems.
Specified Condition:
T=10 N*m (102 kgf*cm, 7 ft.*lbf)
|
|
(d) Disconnect the motor cable from the hybrid vehicle transaxle assembly.
(e) Check for arc marks at the terminals for the generator cable.
Result
|
Proceed to
|
The terminals are connected securely and there are no contact problems.
|
There are no arc marks.
|
A
|
The terminals are not connected securely and there is a contact problem.
|
There are arc marks.
|
B
|
The terminals are not connected securely and there is a contact problem.
|
There are no arc marks.
|
C
|
The terminals are connected securely and there are no contact problems.
|
There are arc marks.
|
B
|
(f) Reconnect the motor cable.
(g) Reinstall the inverter with converter assembly.
B |
|
REPLACE MALFUNCTIONING PARTS
|
C |
|
CONNECT SECURELY
|
A
|
|
|
4.
|
CHECK MOTOR CABLE (FOR MG1)
|
CAUTION:
Be sure to wear insulated gloves.
(a) Check that the service plug grip is not installed.
NOTICE:
After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
(b) Remove the inverter with converter assembly.
(c) Remove the motor cable.
(d) Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.
*1
|
Shield Ground
|
-
|
-
|
*a
|
Motor Cable
|
-
|
-
|
NOTICE:
Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.
Standard Resistance:
Tester Connection
|
Condition
|
Specified Condition
|
d2-4 (W) or d1-4 (W) - Shield ground
|
Ignition switch off
|
10 MΩ or higher
|
d2-5 (U) or d1-5 (U) - Shield ground
|
Ignition switch off
|
10 MΩ or higher
|
d2-6 (V) or d1-6 (V) - Shield ground
|
Ignition switch off
|
10 MΩ or higher
|
NOTICE:
Wrap the terminals of the motor cable with insulating tape to prevent them from coming into contact with body ground.
(e) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
|
Condition
|
Specified Condition
|
d2-4 (W) - d1-4 (W)
|
Ignition switch off
|
Below 1 Ω
|
d2-5 (U) - d1-5 (U)
|
Ignition switch off
|
Below 1 Ω
|
d2-6 (V) - d1-6 (V)
|
Ignition switch off
|
Below 1 Ω
|
d2-4 (W) - d1-5 (U)
|
Ignition switch off
|
10 MΩ or higher
|
d2-5 (U) - d1-6 (V)
|
Ignition switch off
|
10 MΩ or higher
|
d2-6 (V) - d1-4 (W)
|
Ignition switch off
|
10 MΩ or higher
|
(f) Reinstall the motor cable.
(g) Reinstall the inverter with converter assembly.
|