Microcomputer malfunction
|
Hybrid control system
|
P060647
|
Hybrid/EV Powertrain Control Module Processor Watchdog / Safety MCU Failure
|
P060687
|
Hybrid/EV Powertrain Control Module Processor to Monitoring Processor Missing Message
|
P060A47
|
Hybrid/EV Powertrain Control Module Monitoring Processor Watchdog / Safety MCU Failure
|
P060A87
|
Hybrid/EV Powertrain Control Module Processor from Monitoring Processor Missing Message
|
P0A1B49
|
Drive Motor "A" Control Module Internal Electronic Failure
|
P1C9E9F
|
Hybrid/EV System Reset Stuck Off
|
Motor generator control system
|
P0A1B1F
|
Generator Control Module Circuit Intermittent
|
P0A1A47
|
Generator Control Module Watchdog / Safety MC Failure
|
P0A1A49
|
Generator Control Module Internal Electronic Failure
|
P1C2A1C
|
Generator A/D Converter Circuit Circuit Voltage Out of Range
|
P1C2A49
|
Generator A/D Converter Circuit Internal Electronic Failure
|
P1C2B1C
|
Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range
|
P1C2B49
|
Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure
|
P1CAC49
|
Generator Position Sensor Internal Electronic Failure
|
P1CAD49
|
Drive Motor "A" Position Sensor Internal Electronic Failure
|
P1CAF38
|
Generator Position Sensor REF Signal Cycle Malfunction Signal Frequency Incorrect
|
P1CB038
|
Drive Motor "A" Position Sensor REF Signal Frequency Incorrect
|
P313383
|
Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect
|
P313386
|
Communication Error from Generator to Drive Motor "A" Signal Invalid
|
P313387
|
Communication Error from Generator to Drive Motor "A" Missing Message
|
Power source circuit malfunction
|
Motor generator control system
|
P06D61C
|
Generator Control Module Offset Power Circuit Voltage Out of Range
|
P06B01C
|
Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range
|
Communication system malfunction
|
Hybrid control system
|
P312387
|
Lost Communication with Drive Motor Control Module "A" from Hybrid/EV Control Module Missing Message
|
Sensor and actuator circuit malfunction
|
Hybrid control system
|
P0AD911
|
Hybrid/EV Battery Positive Contactor Circuit Short to Ground
|
P0AD915
|
Hybrid/EV Battery Positive Contactor Circuit Short to Auxiliary Battery or Open
|
P0ADD11
|
Hybrid/EV Battery Negative Contactor Circuit Short to Ground
|
P0ADD15
|
Hybrid/EV Battery Negative Contactor Circuit Short to Auxiliary Battery or Open
|
P0AE411
|
Hybrid/EV Battery Precharge Contactor Circuit Short to Ground
|
P0AE415
|
Hybrid/EV Battery Precharge Contactor Circuit Short to Auxiliary Battery or Open
|
Motor generator control system
|
P0A3F16
|
Drive Motor "A" Position Sensor Circuit Voltage Below Threshold
|
P0A4B16
|
Generator Position Sensor Circuit Voltage Below Threshold
|
P0A4B21
|
Generator Position Sensor Signal Amplitude < Minimum
|
P0A4B22
|
Generator Position Sensor Signal Amplitude > Maximum
|
P0C5013
|
Drive Motor "A" Position Sensor Circuit "A" Circuit Open
|
P0C5016
|
Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Below Threshold
|
P0C5017
|
Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Above Threshold
|
P0C5A13
|
Drive Motor "A" Position Sensor Circuit "B" Circuit Open
|
P0C5A16
|
Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Below Threshold
|
P0C5A17
|
Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Above Threshold
|
P0C6413
|
Generator Position Sensor Circuit "A" Circuit Open
|
P0C6416
|
Generator Position Sensor Circuit "A" Circuit Voltage Below Threshold
|
P0C6417
|
Generator Position Sensor Circuit "A" Circuit Voltage Above Threshold
|
P0C6913
|
Generator Position Sensor Circuit "B" Circuit Open
|
P0C6916
|
Generator Position Sensor Circuit "B" Circuit Voltage Below Threshold
|
P0C6917
|
Generator Position Sensor Circuit "B" Circuit Voltage Above Threshold
|
System malfunction
|
Hybrid control system
|
P0D2D1C
|
Drive Motor "A" Inverter Voltage Sensor Voltage Out of Range
|
P1C8349
|
High Voltage Power Resource Circuit Voltage Sensor after Boosting Malfunction
|
Motor generator control system
|
P0D2D16
|
Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Voltage Below Threshold
|
P0D2D17
|
Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Voltage Above Threshold
|
P1CB69E
|
Drive Motor "A" Inverter Voltage Sensor (VH) Stuck On
|