Last Modified: 01-30-2024 |
6.11:8.1.0 |
Doc ID: RM100000001H6J3 |
Model Year Start: 2019 |
Model: RAV4 |
Prod Date Range: [02/2019 -
] |
Title: LIGHTING (EXT): RELAY: ON-VEHICLE INSPECTION; 2019 - 2024 MY RAV4 RAV4 HV [02/2019 - ] |
ON-VEHICLE INSPECTION
PROCEDURE
1. INSPECT HEADLIGHT RELAY
(a) Inspect the headlight dimmer relay (H-LP LH relay).
(1) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
|
Auxiliary Battery Connection
|
Specified Condition
|
3 - 5
|
Auxiliary battery voltage is not applied to terminals 1 and 2
|
10 kΩ or higher
|
Auxiliary battery voltage is applied to terminals 1 and 2
|
Below 1 Ω
|
|
|
(b) Inspect the headlight dimmer relay (H-LP RH relay).
(1) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
|
Auxiliary Battery Connection
|
Specified Condition
|
3 - 5
|
Auxiliary battery voltage is not applied to terminals 1 and 2
|
10 kΩ or higher
|
Auxiliary battery voltage is applied to terminals 1 and 2
|
Below 1 Ω
|
|
|
2. INSPECT HEADLIGHT DIMMER RELAY
(a) Inspect the headlight dimmer relay (DIM relay).
(1) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
|
Auxiliary Battery Connection
|
Specified Condition
|
3 - 5
|
Auxiliary battery voltage is not applied to terminals 1 and 2
|
10 kΩ or higher
|
Auxiliary battery voltage is applied to terminals 1 and 2
|
Below 1 Ω
|
|
|
3. INSPECT RUNNING LIGHT RELAY
(a) Inspect the running light relay (DRL relay).
(1) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
|
Auxiliary Battery Connection
|
Specified Condition
|
3 - 5
|
Auxiliary battery voltage is not applied to terminals 1 and 2
|
10 kΩ or higher
|
Auxiliary battery voltage is applied to terminals 1 and 2
|
Below 1 Ω
|
|
|
4. INSPECT FOG LIGHT RELAY
(a) Inspect the fog light relay (FOG FR relay).
(1) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
|
Auxiliary Battery Connection
|
Specified Condition
|
3 - 5
|
Auxiliary battery voltage is not applied to terminals 1 and 2
|
10 kΩ or higher
|
Auxiliary battery voltage is applied to terminals 1 and 2
|
Below 1 Ω
|
|
|
|