                           Last Modified: 05-08-2025 | 
                        6.11:8.1.0  | 
                        
                           Doc ID: RM100000001H6J3 | 
                      
                     
                        | 
                           Model Year Start: 2019 | 
                        
                           Model: RAV4 | 
                        
                           Prod Date Range: [02/2019 -                    
                                       ] | 
                      
                     
                        | 
                           Title: LIGHTING (EXT): RELAY: ON-VEHICLE INSPECTION; 2019 - 2025 MY RAV4 RAV4 HV [02/2019 -        ] | 
                      
                   
                  ON-VEHICLE INSPECTION
                   
                  PROCEDURE
                   
                  1. INSPECT HEADLIGHT RELAY 
                  
                     
                        
                           | 
                               (a) Inspect the headlight dimmer relay (H-LP LH relay). 
                              (1) Measure the resistance according to the value(s) in the table below. 
                              Standard Resistance:  
                              
                                 
                                 
                                 
                                 
                                    
                                       | 
                                           Tester Connection 
                                        | 
                                       
                                           Auxiliary Battery Connection 
                                        | 
                                       
                                           Specified Condition 
                                        | 
                                     
                                 
                                 
                                    
                                       
                                     
                                 
                                 
                                    
                                       | 
                                           3 - 5 
                                        | 
                                       
                                           Auxiliary battery voltage is not applied to terminals 1 and 2 
                                        | 
                                       
                                           10 kΩ or higher 
                                        | 
                                     
                                    
                                       | 
                                           Auxiliary battery voltage is applied to terminals 1 and 2 
                                        | 
                                       
                                           Below 1 Ω 
                                        | 
                                     
                                 
                               
                            | 
                           
                              
                            | 
                         
                     
                   
                  
                     
                        
                           | 
                               (b) Inspect the headlight dimmer relay (H-LP RH relay). 
                              (1) Measure the resistance according to the value(s) in the table below. 
                              Standard Resistance:  
                              
                                 
                                 
                                 
                                 
                                    
                                       | 
                                           Tester Connection 
                                        | 
                                       
                                           Auxiliary Battery Connection 
                                        | 
                                       
                                           Specified Condition 
                                        | 
                                     
                                 
                                 
                                    
                                       
                                     
                                 
                                 
                                    
                                       | 
                                           3 - 5 
                                        | 
                                       
                                           Auxiliary battery voltage is not applied to terminals 1 and 2 
                                        | 
                                       
                                           10 kΩ or higher 
                                        | 
                                     
                                    
                                       | 
                                           Auxiliary battery voltage is applied to terminals 1 and 2 
                                        | 
                                       
                                           Below 1 Ω 
                                        | 
                                     
                                 
                               
                            | 
                           
                              
                            | 
                         
                     
                   
                   
                  2. INSPECT HEADLIGHT DIMMER RELAY 
                  
                     
                        
                           | 
                               (a) Inspect the headlight dimmer relay (DIM relay). 
                              (1) Measure the resistance according to the value(s) in the table below. 
                              Standard Resistance:  
                              
                                 
                                 
                                 
                                 
                                    
                                       | 
                                           Tester Connection 
                                        | 
                                       
                                           Auxiliary Battery Connection 
                                        | 
                                       
                                           Specified Condition 
                                        | 
                                     
                                 
                                 
                                    
                                       
                                     
                                 
                                 
                                    
                                       | 
                                           3 - 5 
                                        | 
                                       
                                           Auxiliary battery voltage is not applied to terminals 1 and 2 
                                        | 
                                       
                                           10 kΩ or higher 
                                        | 
                                     
                                    
                                       | 
                                           Auxiliary battery voltage is applied to terminals 1 and 2 
                                        | 
                                       
                                           Below 1 Ω 
                                        | 
                                     
                                 
                               
                            | 
                           
                              
                            | 
                         
                     
                   
                   
                  3. INSPECT RUNNING LIGHT RELAY 
                  
                     
                        
                           | 
                               (a) Inspect the running light relay (DRL relay). 
                              (1) Measure the resistance according to the value(s) in the table below. 
                              Standard Resistance:  
                              
                                 
                                 
                                 
                                 
                                    
                                       | 
                                           Tester Connection 
                                        | 
                                       
                                           Auxiliary Battery Connection 
                                        | 
                                       
                                           Specified Condition 
                                        | 
                                     
                                 
                                 
                                    
                                       
                                     
                                 
                                 
                                    
                                       | 
                                           3 - 5 
                                        | 
                                       
                                           Auxiliary battery voltage is not applied to terminals 1 and 2 
                                        | 
                                       
                                           10 kΩ or higher 
                                        | 
                                     
                                    
                                       | 
                                           Auxiliary battery voltage is applied to terminals 1 and 2 
                                        | 
                                       
                                           Below 1 Ω 
                                        | 
                                     
                                 
                               
                            | 
                           
                              
                            | 
                         
                     
                   
                   
                  4. INSPECT FOG LIGHT RELAY 
                  
                     
                        
                           | 
                               (a) Inspect the fog light relay (FOG FR relay). 
                              (1) Measure the resistance according to the value(s) in the table below. 
                              Standard Resistance:  
                              
                                 
                                 
                                 
                                 
                                    
                                       | 
                                           Tester Connection 
                                        | 
                                       
                                           Auxiliary Battery Connection 
                                        | 
                                       
                                           Specified Condition 
                                        | 
                                     
                                 
                                 
                                    
                                       
                                     
                                 
                                 
                                    
                                       | 
                                           3 - 5 
                                        | 
                                       
                                           Auxiliary battery voltage is not applied to terminals 1 and 2 
                                        | 
                                       
                                           10 kΩ or higher 
                                        | 
                                     
                                    
                                       | 
                                           Auxiliary battery voltage is applied to terminals 1 and 2 
                                        | 
                                       
                                           Below 1 Ω 
                                        | 
                                     
                                 
                               
                            | 
                           
                              
                            | 
                         
                     
                   
                  
                |