Shutter Operation State
|
Grille shutter operation state
|
Standby, Open, Close or Prohibit
|
Standby: Grille shutter in standby mode
Open: Grille shutter opening
Close: Grille shutter closing
Prohibit: Grille shutter operation disabled
|
-
|
Shutter Control State
|
Grille shutter control state
|
Normal or Maintenance
|
Normal: Normal mode
Maintenance: Maintenance mode
|
-
|
Close Motor Lock
|
Motor lock detection state during grille shutter closing operation
|
Undetected or Detected
|
Undetected: Motor lock not detected during closing operation
Detected: Motor lock detected during closing operation
|
Displays state of last closing operation
|
Open Motor Lock
|
Motor lock detection state during grille shutter opening operation
|
Undetected or Detected
|
Undetected: Motor lock not detected during opening operation
Detected: Motor lock detected during opening operation
|
Displays state of last opening operation
|
+B Power Voltage
|
Auxiliary battery voltage
|
Min.: 0.8 V, Max.: 20 V
|
11 to 14 V
|
-
|
Last Operation Direction
|
Direction of last grille shutter operation
|
Unknown, Open or Close
|
Unknown: Direction of last grille shutter operation unknown
Open: Last grille shutter operation was in opening direction
Close: Last grille shutter operation was in closing direction
|
-
|
Shutter Operation Initialization Result
|
Result of grille shutter system initialization
|
OK or NG
|
OK: Initialization was completed successfully
NG: Initialization was not completed successfully
|
-
|
Shutter Operation Half-Open Result for Active Test
|
Result of Active Test Shutter Half-Open Operation
|
OK or NG
|
OK: Operation is normal
NG: Operation is abnormal
|
-
|
Shutter Operation Lock Detection Result for Active Test
|
Result of Active Test Shutter Closing Operation Lock Detection and Shutter Opening Operation Lock Detection
|
Normal, Open Error or Close Error
|
Normal: Normal lock detected
Open Error: Lock detected in abnormal position while performing Active Test Shutter Opening Operation Lock Detection
Close Error: Lock detected in abnormal position while performing Active Test Shutter Closing Operation Lock Detection
|
-
|
Shutter Operation Fixed Length Result for Active Test
|
Result of Active Test Shutter Closing Operation Fixed Length and Shutter Opening Operation Fixed Length
|
Normal, Open Error or Close Error
|
Normal: Normal operation length
Open Error: Abnormal operation length while performing Active Test Shutter Opening Operation Fixed Length
Close Error: Abnormal operation length while performing Active Test Shutter Closing Operation Fixed Length
|
-
|
Shutter Operation Mode
|
Grille shutter operation mode
|
Normal Mode, Change Sleep Mode, Sleep Mode or Release Sleep Mode
|
Normal Mode: Normal mode
Change Sleep Mode: Winter control transition mode
Sleep Mode: Winter control mode
Release Sleep Mode: Winter control cancel mode
|
-
|
Last Operation Pulse Value
|
Number of pulses of last grille shutter operation
|
0 to 65535 edge
|
Between 0 to 65535 edge
|
-
|
Current Position
|
Current grille shutter position
|
0 to 65535 edge
|
Between 0 to 65535 edge
|
-
|
Maximum Open Position
|
Grille shutter open position
|
0 to 65535 edge
|
Between 0 to 65535 edge
|
-
|
Maximum Close Position
|
Grille shutter closed position
|
0 to 65535 edge
|
Between 0 to 65535 edge
|
-
|
Shutter Initialization
|
Grille shutter system initialization
|
Incomplete or Complete
|
Incomplete: Grille shutter system initialization has not been completed
Complete: Grille shutter system initialization has been completed
|
-
|
End Shaft SW
|
End shaft switch state*
|
Unset, Fully Open Position, Fully Closed Position or Half Open Position
|
Unset: Grille shutter position unknown
Fully Open Position: Grille shutter in fully open position
Fully Closed Position: Grille shutter in fully closed position
Half Open Position: Grille shutter between fully open and fully closed position
|
Not applicable
|
Ambient Temperature
|
Ambient Temperature
|
-78.75 to 78.125°C
|
Actual ambient temperature displayed (in °C)
|
-
|
Regulator Pressure Sensor
|
Refrigerant pressure
|
0.0147 to 3.7450 MPa
|
Actual refrigerant pressure displayed (in MPa)
|
-
|
Engine Coolant Temperature
|
Engine coolant temperature
|
16 to 127°C
|
Actual engine coolant temperature displayed (in °C)
|
-
|
Code Clear Request Flag
|
Reception condition of DTC clear request signal to the grille shutter ECU from the ECM
|
0 or 1
|
0: Not receiving DTC clear request signal
1: Receiving DTC clear request signal
|
-
|
Driving Cycle Change Flag
|
Reception condition of driving cycle transition signal from ECM*
|
0 or 1
|
0: Not receiving driving cycle transition signal
1: Receiving driving cycle transition signal
|
Not applicable
|
IG SW
|
Ignition switch
|
0 or 1
|
0: Ignition switch off or ACC
1: Ignition switch ON
|
-
|
HV/EV Control Coolant Temperature
|
Inverter coolant temperature
|
16 to 127°C
|
Actual inverter coolant temperature displayed (in °C)
|
-
|
Shutter Open Request
|
Reception condition of grille shutter open request signal from hybrid vehicle control ECU assembly
|
0 or 1
|
0: Not receiving grille shutter open request signal
1: Receiving grille shutter open request signal
|
-
|
HV/EV Control Coolant Temperature Error Flag
|
Inverter coolant temperature sensor condition sent from hybrid vehicle control ECU assembly
|
0 or 1
|
0: Inverter coolant temperature sensor is normal
1: Inverter coolant temperature sensor is malfunctioning
|
-
|
Vehicle Speed
|
Vehicle speed
|
0 to 255 km/h
|
Actual vehicle speed displayed (in km/h)
|
-
|
Number of DTC
|
Number of DTCs currently stored
|
0 to 255
|
Number of DTCs will be displayed
|
-
|