                               Shutter Operation State 
                            | 
                           
                               Grille shutter operation state 
                            | 
                           
                               Standby, Open, Close or Prohibit 
                            | 
                           
                               Standby: Grille shutter in standby mode 
                              Open: Grille shutter opening 
                              Close: Grille shutter closing 
                              Prohibit: Grille shutter operation disabled 
                            | 
                           
                               - 
                            | 
                        
                        
                           | 
                               Shutter Control State 
                            | 
                           
                               Grille shutter control state 
                            | 
                           
                               Normal or Maintenance 
                            | 
                           
                               Normal: Normal mode 
                              Maintenance: Maintenance mode 
                            | 
                           
                               - 
                            | 
                        
                        
                           | 
                               Close Motor Lock 
                            | 
                           
                               Motor lock detection state during grille shutter closing operation 
                            | 
                           
                               Undetected or Detected 
                            | 
                           
                               Undetected: Motor lock not detected during closing operation 
                              Detected: Motor lock detected during closing operation 
                            | 
                           
                               Displays state of last closing operation 
                            | 
                        
                        
                           | 
                               Open Motor Lock 
                            | 
                           
                               Motor lock detection state during grille shutter opening operation 
                            | 
                           
                               Undetected or Detected 
                            | 
                           
                               Undetected: Motor lock not detected during opening operation 
                              Detected: Motor lock detected during opening operation 
                            | 
                           
                               Displays state of last opening operation 
                            | 
                        
                        
                           | 
                               +B Power Voltage 
                            | 
                           
                               Auxiliary battery voltage 
                            | 
                           
                               Min.: 0.8 V, Max.: 20 V 
                            | 
                           
                               11 to 14 V 
                            | 
                           
                               - 
                            | 
                        
                        
                           | 
                               Last Operation Direction 
                            | 
                           
                               Direction of last grille shutter operation 
                            | 
                           
                               Unknown, Open or Close 
                            | 
                           
                               Unknown: Direction of last grille shutter operation unknown 
                              Open: Last grille shutter operation was in opening direction 
                              Close: Last grille shutter operation was in closing direction 
                            | 
                           
                               - 
                            | 
                        
                        
                           | 
                               Shutter Operation Initialization Result 
                            | 
                           
                               Result of grille shutter system initialization 
                            | 
                           
                               OK or NG 
                            | 
                           
                               OK: Initialization was completed successfully 
                              NG: Initialization was not completed successfully 
                            | 
                           
                               - 
                            | 
                        
                        
                           | 
                               Shutter Operation Half-Open Result for Active Test 
                            | 
                           
                               Result of Active Test Shutter Half-Open Operation 
                            | 
                           
                               OK or NG 
                            | 
                           
                               OK: Operation is normal 
                              NG: Operation is abnormal 
                            | 
                           
                               - 
                            | 
                        
                        
                           | 
                               Shutter Operation Lock Detection Result for Active Test 
                            | 
                           
                               Result of Active Test Shutter Closing Operation Lock Detection and Shutter Opening Operation Lock Detection 
                            | 
                           
                               Normal, Open Error or Close Error 
                            | 
                           
                               Normal: Normal lock detected 
                              Open Error: Lock detected in abnormal position while performing Active Test Shutter Opening Operation Lock Detection 
                              Close Error: Lock detected in abnormal position while performing Active Test Shutter Closing Operation Lock Detection 
                            | 
                           
                               - 
                            | 
                        
                        
                           | 
                               Shutter Operation Fixed Length Result for Active Test 
                            | 
                           
                               Result of Active Test Shutter Closing Operation Fixed Length and Shutter Opening Operation Fixed Length 
                            | 
                           
                               Normal, Open Error or Close Error 
                            | 
                           
                               Normal: Normal operation length 
                              Open Error: Abnormal operation length while performing Active Test Shutter Opening Operation Fixed Length 
                              Close Error: Abnormal operation length while performing Active Test Shutter Closing Operation Fixed Length 
                            | 
                           
                               - 
                            | 
                        
                        
                           | 
                               Shutter Operation Mode 
                            | 
                           
                               Grille shutter operation mode 
                            | 
                           
                               Normal Mode, Change Sleep Mode, Sleep Mode or Release Sleep Mode 
                            | 
                           
                               Normal Mode: Normal mode 
                              Change Sleep Mode: Winter control transition mode 
                              Sleep Mode: Winter control mode 
                              Release Sleep Mode: Winter control cancel mode 
                            | 
                           
                               - 
                            | 
                        
                        
                           | 
                               Last Operation Pulse Value 
                            | 
                           
                               Number of pulses of last grille shutter operation 
                            | 
                           
                               0 to 65535 edge 
                            | 
                           
                               Between 0 to 65535 edge 
                            | 
                           
                               - 
                            | 
                        
                        
                           | 
                               Current Position 
                            | 
                           
                               Current grille shutter position 
                            | 
                           
                               0 to 65535 edge 
                            | 
                           
                               Between 0 to 65535 edge 
                            | 
                           
                               - 
                            | 
                        
                        
                           | 
                               Maximum Open Position 
                            | 
                           
                               Grille shutter open position 
                            | 
                           
                               0 to 65535 edge 
                            | 
                           
                               Between 0 to 65535 edge 
                            | 
                           
                               - 
                            | 
                        
                        
                           | 
                               Maximum Close Position 
                            | 
                           
                               Grille shutter closed position 
                            | 
                           
                               0 to 65535 edge 
                            | 
                           
                               Between 0 to 65535 edge 
                            | 
                           
                               - 
                            | 
                        
                        
                           | 
                               Shutter Initialization 
                            | 
                           
                               Grille shutter system initialization 
                            | 
                           
                               Incomplete or Complete 
                            | 
                           
                               Incomplete: Grille shutter system initialization has not been completed 
                              Complete: Grille shutter system initialization has been completed 
                            | 
                           
                               - 
                            | 
                        
                        
                           | 
                               End Shaft SW 
                            | 
                           
                               End shaft switch state* 
                            | 
                           
                               Unset, Fully Open Position, Fully Closed Position or Half Open Position 
                            | 
                           
                               Unset: Grille shutter position unknown 
                              Fully Open Position: Grille shutter in fully open position 
                              Fully Closed Position: Grille shutter in fully closed position 
                              Half Open Position: Grille shutter between fully open and fully closed position 
                            | 
                           
                               Not applicable 
                            | 
                        
                        
                           | 
                               Ambient Temperature 
                            | 
                           
                               Ambient Temperature 
                            | 
                           
                               -78.75 to 78.125°C 
                            | 
                           
                               Actual ambient temperature displayed (in °C) 
                            | 
                           
                               - 
                            | 
                        
                        
                           | 
                               Regulator Pressure Sensor 
                            | 
                           
                               Refrigerant pressure 
                            | 
                           
                               0.0147 to 3.7450 MPa 
                            | 
                           
                               Actual refrigerant pressure displayed (in MPa) 
                            | 
                           
                               - 
                            | 
                        
                        
                           | 
                               Engine Coolant Temperature 
                            | 
                           
                               Engine coolant temperature 
                            | 
                           
                               16 to 127°C 
                            | 
                           
                               Actual engine coolant temperature displayed (in °C) 
                            | 
                           
                               - 
                            | 
                        
                        
                           | 
                               Code Clear Request Flag 
                            | 
                           
                               Reception condition of DTC clear request signal to the grille shutter ECU from the ECM 
                            | 
                           
                               0 or 1 
                            | 
                           
                               0: Not receiving DTC clear request signal 
                              1: Receiving DTC clear request signal 
                            | 
                           
                               - 
                            | 
                        
                        
                           | 
                               Driving Cycle Change Flag 
                            | 
                           
                               Reception condition of driving cycle transition signal from ECM* 
                            | 
                           
                               0 or 1 
                            | 
                           
                               0: Not receiving driving cycle transition signal 
                              1: Receiving driving cycle transition signal 
                            | 
                           
                               Not applicable 
                            | 
                        
                        
                           | 
                               IG SW 
                            | 
                           
                               Ignition switch 
                            | 
                           
                               0 or 1 
                            | 
                           
                               0: Ignition switch off or ACC 
                              1: Ignition switch ON 
                            | 
                           
                               - 
                            | 
                        
                        
                           | 
                               HV/EV Control Coolant Temperature 
                            | 
                           
                               Inverter coolant temperature 
                            | 
                           
                               16 to 127°C 
                            | 
                           
                               Actual inverter coolant temperature displayed (in °C) 
                            | 
                           
                               - 
                            | 
                        
                        
                           | 
                               Shutter Open Request 
                            | 
                           
                               Reception condition of grille shutter open request signal from hybrid vehicle control ECU assembly 
                            | 
                           
                               0 or 1 
                            | 
                           
                               0: Not receiving grille shutter open request signal 
                              1: Receiving grille shutter open request signal 
                            | 
                           
                               - 
                            | 
                        
                        
                           | 
                               HV/EV Control Coolant Temperature Error Flag 
                            | 
                           
                               Inverter coolant temperature sensor condition sent from hybrid vehicle control ECU assembly 
                            | 
                           
                               0 or 1 
                            | 
                           
                               0: Inverter coolant temperature sensor is normal 
                              1: Inverter coolant temperature sensor is malfunctioning 
                            | 
                           
                               - 
                            | 
                        
                        
                           | 
                               Vehicle Speed 
                            | 
                           
                               Vehicle speed 
                            | 
                           
                               0 to 255 km/h 
                            | 
                           
                               Actual vehicle speed displayed (in km/h) 
                            | 
                           
                               - 
                            | 
                        
                        
                           | 
                               Number of DTC 
                            | 
                           
                               Number of DTCs currently stored 
                            | 
                           
                               0 to 255 
                            | 
                           
                               Number of DTCs will be displayed 
                            | 
                           
                               - 
                            |