Last Modified: 01-30-2024 |
6.11:8.1.0 |
Doc ID: RM100000001HIRF |
Model Year Start: 2019 |
Model: RAV4 HV |
Prod Date Range: [02/2019 -
] |
Title: HEATING / AIR CONDITIONING: AIR CONDITIONING SYSTEM (for HV Model): A/C Switch Indicator does not Turn On; 2019 - 2024 MY RAV4 HV [02/2019 - ] |
A/C Switch Indicator does not Turn On
|
DESCRIPTION
If none of the indicators on the air conditioning control assembly illuminate, the following malfunctions are possible.
Malfunction Status
|
Factor
|
None of the indicators on the air conditioning control assembly illuminate
|
-
Air conditioning amplifier assembly malfunction
-
A/C switch (air conditioning control assembly) malfunction
-
Malfunction in one of the servo motors (initialization incomplete)
-
Damper and link operation (jamming)
-
Refrigerant pressure malfunction (low pressure)
-
Low ambient temperature (including thermistor assembly)
|
PROCEDURE
1.
|
CHECK MALFUNCTION STATUS
|
(a) Check the malfunction status of switch indicators on the air conditioning control assembly.
Result
|
Proceed to
|
A/C switch indicators are not always illuminated
|
A
|
A/C switch indicators are not illuminated only immediately after starting the hybrid control system
|
B
|
A
|
|
|
2.
|
READ VALUE USING TECHSTREAM (AMBIENT TEMP SENSOR)
|
(a) Connect the Techstream to the DLC3.
(b) Turn the ignition switch to ON.
(c) Turn the Techstream on.
(d) Enter the following menus: Body Electrical / Air Conditioner / Data List.
(e) Read the Data List according to the display on the Techstream.
Body Electrical > Air Conditioner > Data List
Tester Display
|
Measurement Item
|
Range
|
Normal Condition
|
Diagnostic Note
|
Ambient Temp Sensor
|
Thermistor assembly
|
Min.: -23.30°C (-9.94°F)
Max.: 65.95°C (150.71°F)
|
Actual ambient temperature displayed
|
Thermistor assembly system malfunction
-
When open circuit: -23.30°C (-9.94°F)
-
When short circuit: 65.95°C (150.71°F)
|
Body Electrical > Air Conditioner > Data List
Tester Display
|
Ambient Temp Sensor
|
OK:
The display is as specified in the normal condition column (0°C (32°F) or higher).
|