MIL
|
MIL status
|
ON or OFF
|
OFF
|
-
|
Number of Emission DTC
|
Emissions-related DTCs
|
-
|
-
|
-
|
Complete Parts Monitor
|
Comprehensive component monitor
|
Not Avl or Avail
|
-
|
-
|
Fuel System Monitor
|
Fuel system monitor
|
Not Avl or Avail
|
-
|
-
|
Misfire Monitor
|
Misfire monitor
|
Not Avl or Avail
|
-
|
-
|
EGR/VVT Monitor
|
EGR/VVT monitor
|
Not Avl or Avail
|
-
|
-
|
A/F (O2) Sensor Heater Monitor
|
O2S (A/FS) heater monitor
|
Not Avl or Avail
|
-
|
-
|
A/F (O2) Sensor Monitor
|
O2S (A/FS) monitor
|
Not Avl or Avail
|
-
|
-
|
Secondary Air Injection System Monitor
|
Secondary air injection system monitor
|
Not Avl or Avail
|
-
|
-
|
EVAP Monitor
|
EVAP monitor
|
Not Avl or Avail
|
-
|
-
|
Heated Catalyst Monitor
|
Heated catalyst monitor
|
Not Avl or Avail
|
-
|
-
|
Catalyst Monitor
|
Catalyst monitor
|
Not Avl or Avail
|
-
|
-
|
EGR/VVT Monitor Result
|
EGR/VVT monitor result
|
Compl or Incmpl
|
-
|
-
|
A/F (O2) Sensor Heater Monitor Result
|
A/F (O2) sensor heater monitor result
|
Compl or Incmpl
|
-
|
-
|
A/F (O2) Sensor Monitor Result
|
A/F (O2) sensor monitor result
|
Compl or Incmpl
|
-
|
-
|
Secondary Air Injection System Monitor Result
|
Secondary air injection system monitor result
|
Compl or Incmpl
|
-
|
-
|
EVAP Monitor Result
|
EVAP monitor result
|
Compl or Incmpl
|
-
|
-
|
Heated Catalyst Monitor Result
|
Heated catalyst monitor result
|
Compl or Incmpl
|
-
|
-
|
Catalyst Monitor Result
|
Catalyst monitor result
|
Compl or Incmpl
|
-
|
-
|
Calculate Load
|
Calculate load (value increases in proportion to increase in load)
|
Min.: 0.0%, Max.: 100.0%
|
-
|
-
|
Coolant Temperature
|
Engine coolant temperature
|
Min.: -40°C (-40°F), Max.: 215°C (419°F)
|
Cold start→Fully warmed up:
Gradually rises
After warming up:
75 to 100°C (167 to 212°F)
|
-
|
Engine Speed
|
Engine speed
|
Min.: 0 rpm, Max.: 16383 rpm
|
Engine stopped:
0 rpm
While engine running at a constant speed:
No significant fluctuation
|
-
|
Vehicle Speed
|
Vehicle speed
|
Min.: 0 km/h (0 mph), Max.: 255 km/h (158 mph)
|
Vehicle stopped:
0 km/h (0 mph)
While driving at a constant speed:
No significant fluctuation
|
-
|
Intake Air Temperature
|
Intake air temperature
|
Min.: -40°C (-40°F), Max.: 140°C (284°F)
|
Constant:
Same as ambient air temperature
|
-
|
Throttle Position Sensor No.1 Voltage %
|
Throttle position sensor
|
Min.: 0.0%, Max.: 100.0%
|
-
|
-
|
OBD Requirements
|
OBD requirement
|
-
|
-
|
-
|
Engine Run Time
|
Elapsed time after starting engine
|
Min.: 0 sec, Max.: 65535 sec
|
-
|
Elapsed time from initial engine start until the ignition switch is turned off.
|
MIL ON Run Distance
|
Drive distance from MIL on
|
Min.: 0 km (0 mile), Max.: 65535 km (40723 mile)
|
-
|
-
|
Warmup Cycle Cleared DTC
|
Warmup cycles after DTCs cleared
|
Min.: 0, Max.: 255
|
-
|
-
|
Distance from DTC Cleared
|
Distance driven after DTCs cleared
|
Min.: 0 km (0 mile), Max.: 65535 km (40723 mile)
|
-
|
-
|
Atmospheric Pressure
|
Atmospheric pressure
|
Min.: 0 kPa, Max.: 255 kPa
|
Constant:
Atmosphere pressure
|
-
|
Component Monitor Result (Current)
|
Comprehensive component monitor (Current)
|
Compl or Incmpl
|
-
|
-
|
Fuel System Monitor Result (Current)
|
Fuel system monitor result (Current)
|
Compl or Incmpl
|
-
|
-
|
Misfire Monitor Result (Current)
|
Misfire monitor result (Current)
|
Compl or Incmpl
|
-
|
-
|
Component Monitor ENA (Current)
|
Comprehensive component monitor
|
Unable or Enable
|
-
|
-
|
Fuel System Monitor ENA (Current)
|
Fuel system monitor ENA (Current)
|
Unable or Enable
|
-
|
-
|
Misfire Monitor ENA (Current)
|
Misfire monitor ENA (Current)
|
Unable or Enable
|
-
|
-
|
EGR/VVT Monitor ENA (Current)
|
EGR/VVT monitor ENA (Current)
|
Unable or Enable
|
-
|
-
|
O2 Sensor Heater ENA (Current)
|
O2 sensor heater ENA (Current)
|
Unable or Enable
|
-
|
-
|
A/F (O2) Sensor Monitor ENA (Current)
|
A/F (O2) sensor monitor ENA (Current)
|
Unable or Enable
|
-
|
-
|
Secondary Air Injection System Monitor ENA (Current)
|
Secondary air injection system monitor ENA (Current)
|
Unable or Enable
|
-
|
-
|
EVAP Monitor ENA (Current)
|
EVAP monitor ENA (Current)
|
Unable or Enable
|
-
|
-
|
Heated Catalyst Monitor ENA (Current)
|
Heated catalyst monitor ENA (Current)
|
Unable or Enable
|
-
|
-
|
Catalyst Monitor ENA (Current)
|
Catalyst monitor ENA (Current)
|
Unable or Enable
|
-
|
-
|
EGR/VVT Monitor Result (Current)
|
EGR/VVT monitor result (Current)
|
Compl or Incmpl
|
-
|
-
|
O2 Sensor Heater Monitor Result (Current)
|
O2 sensor heater monitor result (Current)
|
Compl or Incmpl
|
-
|
-
|
A/F (O2) Sensor Monitor Result (Current)
|
A/F (O2) sensor monitor result (Current)
|
Compl or Incmpl
|
-
|
-
|
Secondary Air Injection System Monitor Result (Current)
|
Secondary air injection system monitor result (Current)
|
Compl or Incmpl
|
-
|
-
|
EVAP Monitor Result (Current)
|
EVAP monitor result (Current)
|
Compl or Incmpl
|
-
|
-
|
Heated Catalyst Monitor Result (Current)
|
Heated catalyst monitor result (Current)
|
Compl or Incmpl
|
-
|
-
|
Catalyst Monitor Result (Current)
|
Catalyst monitor result (Current)
|
Compl or Incmpl
|
-
|
-
|
Battery Voltage
|
Auxiliary battery voltage
|
Min.: 0.00 V, Max.: 16.00 V
|
11 to 15 V: Ignition switch ON
|
When ignition switch ON (READY): approx. 12.5 to 15.0 V. When ignition switch ON: same as auxiliary battery voltage (approx. 12 V).
If the voltage becomes 11 V or less when the ignition switch is ON (READY), the hybrid vehicle control ECU assembly stores inverter with converter assembly DTCs.
If the voltage becomes 9.5 V or less, the ignition switch will not be able to be turned to ON (READY).
|
Ambient Temperature
|
Ambient air temperature
|
Min.: -40°C (-40°F), Max.: 215°C (419°F)
|
Ignition switch ON:
Same as ambient air temperature
|
-
|
Running Time from MIL ON
|
Running time from MIL on
|
Min.: 0 min, Max.: 65535 min
|
-
|
-
|
Time after DTC Cleared
|
Time after DTCs cleared
|
Min.: 0 min, Max.: 65535 min
|
-
|
-
|
Shift SW Status (N,P Range)
|
Shift lever position sensor
|
ON or OFF
|
Shift state P or N: ON
Shift state other than P or N: OFF
|
-
|
Hybrid/EV Battery System Voltage
|
HV battery voltage
|
Min.: 0 V, Max.: 510 V
|
Ignition switch ON (READY):
150 to 300 V
|
-
|
Hybrid/EV Battery System Current
|
HV battery current
|
Min.: -3276.8 A, Max.: 3276.7 A
|
Ignition switch ON:
-4 to 4 A
|
-
|
Boosting Converter Temperature(Upper)
|
Boost converter temperature (Upper)
|
Min.: 0°C (32°F), Max.: 150°C (302°F)
|
Vehicle left for 1 day at an ambient temperature of 25°C (77°F):
8 to 35°C (46.4 to 95°F)
While driving with an ambient temperature of 25°C (77°F):
25 to 120°C (77 to 248°F)
|
-
|
Boosting Converter Temperature 1(Lower)
|
Boost converter temperature 1 (Lower)
|
Min.: 0°C (32°F), Max.: 150°C (302°F)
|
Vehicle left for 1 day at an ambient temperature of 25°C (77°F):
8 to 35°C (46.4 to 95°F)
While driving with an ambient temperature of 25°C (77°F):
25 to 120°C (77 to 248°F)
|
-
|
Boosting Converter Temperature Duty(Upper)
|
Boost converter temperature duty (Upper) (CPU input data)
|
Min.: 0.0 %, Max.: 100.0 %
|
-
|
-
|
Motor Inverter Temperature Duty
|
Motor inverter temperature duty (CPU input data)
|
Min.: 0.0 %, Max.: 100.0 %
|
-
|
-
|
Motor Inverter Temperature
|
Motor inverter temperature
|
Min.: 0°C (32°F), Max.: 150°C (302°F)
|
Vehicle left for 1 day at an ambient temperature of 25°C (77°F):
8 to 35°C (46.4 to 95°F)
While driving with an ambient temperature of 25°C (77°F):
25 to 120°C (77 to 248°F)
|
-
|
Motor U Current AD Value(Lower Resolution)
|
Motor U phase current AD value (Lower resolution)
|
Min.: 0.00 V, Max.: 4.99 V
|
-
|
-
|
Motor V Current AD Value(Lower Resolution)
|
Motor V phase current AD value (Lower resolution)
|
Min.: 0.00 V, Max.: 4.99 V
|
-
|
-
|
Motor W Current AD Value(Lower Resolution)
|
Motor W phase current AD value (Lower resolution)
|
Min.: 0.00 V, Max.: 4.99 V
|
-
|
-
|
Motor V Current AD Value(Higher Resolution)
|
Motor V phase current AD value (Higher resolution)
|
Min.: 0.00 V, Max.: 4.99 V
|
-
|
-
|
Motor W Current AD Value(Higher Resolution)
|
Motor W phase current AD value (Higher resolution)
|
Min.: 0.00 V, Max.: 4.99 V
|
-
|
-
|
Motor U Current(Lower Resolution)
|
Motor U phase current (Lower resolution)
|
Min.: -1000 A, Max.: 1000 A
|
-
|
-
|
Motor V Current(Lower Resolution)
|
Motor V phase current (Lower resolution)
|
Min.: -1000 A, Max.: 1000 A
|
-
|
-
|
Motor W Current(Lower Resolution)
|
Motor W phase current (Lower resolution)
|
Min.: -1000 A, Max.: 1000 A
|
-
|
-
|
Generator U Current(Lower Resolution)
|
Generator U phase current (Lower resolution)
|
Min.: -1000 A, Max.: 1000 A
|
-
|
-
|
Generator V Current(Lower Resolution)
|
Generator V phase current (Lower resolution)
|
Min.: -1000 A, Max.: 1000 A
|
-
|
-
|
Generator W Current(Lower Resolution)
|
Generator W phase current (Lower resolution)
|
Min.: -1000 A, Max.: 1000 A
|
-
|
-
|
Motor ECU Power Supply (For 31V)
|
Motor generator control ECU power supply (for 31 V)
|
Min.: 0.00 V, Max.: 4.98 V
|
-
|
-
|
Motor ECU Power Supply (For AD0)
|
Motor generator control ECU power supply (for AD0)
|
Min.: 0.00 V, Max.: 4.98 V
|
-
|
-
|
Motor ECU Power Supply (For 2.5V)
|
Motor generator control ECU power supply (for 2.5 V)
|
Min.: 0.00 V, Max.: 4.98 V
|
-
|
-
|
Motor ECU Power Supply (For 2.5V Sub)
|
Motor generator control ECU power supply (for 2.5 V sub)
|
Min.: 0.00 V, Max.: 4.98 V
|
-
|
-
|
DC/DC Converter Operation State
|
DC/DC converter status voltage
|
Min.: 0.00 V, Max.: 4.98 V
|
-
|
-
|
DC/DC Converter Output Signal
|
DC/DC converter output signal
|
Min.: 0.00 V, Max.: 4.98 V
|
-
|
-
|
DC/DC Converter Output Signal Duty
|
DC/DC converter output signal duty
|
Min.: 0.0 %, Max.: 100.0 %
|
-
|
-
|
Motor Revolution
|
Motor (MG2) speed (detected by resolver sensor)
|
Min.: -20000 rpm, Max.: 20000 rpm
|
While driving:
Varies depending on vehicle speed
|
Motor (MG2) speed changes in proportion to vehicle speed.
Motor (MG2) speed is not influenced by accelerator pedal opening angle, engine speed or generator (MG1) speed.
|
Motor Torque
|
Motor (MG2) torque value
|
Min.: -500 Nm, Max.: 500 Nm
|
While driving:
Varies depending on vehicle operating conditions
|
-
|
Motor Control Mode
|
Motor control mode
|
Min.: 0, Max.: 65535
|
-
|
-
|
Motor Carrier Frequency
|
Motor carrier frequency
|
0.75 kHz, 1.25 kHz, 2.5 kHz, 3.75 kHz, 5 kHz, 10 kHz
|
-
|
-
|
Motor Inverter Shut Down Signal
|
Motor inverter shutdown signal
|
Min.: 0, Max.: 255
|
-
|
-
|
Generator Revolution
|
Generator (MG1) speed (detected by resolver sensor)
|
Min.: -20000 rpm, Max.: 20000 rpm
|
During charge or discharge:
Varies depending on vehicle operating conditions
|
Generator (MG1) speed is set to obtain requested target engine speed
|
Generator Torque
|
Generator (MG1) torque value
|
Min.: -500 Nm, Max.: 500 Nm
|
During charge or discharge:
Varies depending on vehicle operating conditions
|
-
|
Generator Control Mode
|
Generator control mode
|
Min.: 0, Max.: 65535
|
-
|
-
|
Generator Carrier Frequency
|
Generator carrier frequency
|
0.75 kHz, 1.25 kHz, 2.5 kHz, 3.75 kHz, 5 kHz, 10 kHz
|
-
|
-
|
Generator Inverter Shut Down Signal
|
Generator (MG1) inverter shutdown signal
|
Min.: 0, Max.: 255
|
-
|
-
|
Inverter Coolant Temperature AD Value
|
Coolant (for inverter) temperature AD value
|
Min.: 0.00 V, Max.: 4.99 V
|
-
|
-
|
Inverter Coolant Temperature
|
Coolant (for inverter) temperature
|
Min.: -40°C (-40°F), Max.: 110°C (230°F)
|
Cold start→Fully warmed up:
Gradually rises
|
Normal: 65°C (149°F) or less
|
Inverter Input Current
|
Inverter input current
|
Min.: -1000 A, Max.: 1000 A
|
-
|
-
|
Inverter Water Pump Duty
|
Inverter water pump motor driver request duty
|
Min.: 0 %, Max.: 100 %
|
Ignition switch ON (READY):
40 to 85 %
|
Hybrid vehicle control ECU assembly
|
Inverter Water Pump Revolution
|
Inverter water pump assembly speed
|
Min.: 0 rpm, Max.: 15000 rpm
|
Ignition switch ON (READY):
1051 to 8617 rpm
|
When the inverter water pump assembly is not operating:
200 rpm or less
|
Collinear Graphic Engine Revolution
|
Col-linear graphic engine speed
|
Min.: 0 rpm, Max.: 65535 rpm
|
-
|
-
|
Motor Resolver After Offset
|
Motor resolver after offset
|
Min.: 0.000 deg, Max.: 358.593 deg
|
-
|
-
|
Motor Resolver Offset Value
|
Motor resolver offset value
|
Min.: -250.000 deg, Max.: 249.992 deg
|
-
|
-
|
Generator Resolver After Offset
|
Generator resolver after offset
|
Min.: 0.000 deg, Max.: 358.593 deg
|
-
|
-
|
Generator Resolver Offset Value
|
Generator resolver offset value
|
Min.: -250.000 deg, Max.: 249.992 deg
|
-
|
-
|
Motor Resolver Supply Voltage
|
Motor resolver supply voltage
|
Min.: 0.00 V, Max.: 4.99 V
|
-
|
-
|
VL Voltage
|
High voltage before it is boosted
|
Min.: 0.0 V, Max.: 500.0 V
|
Ignition switch ON (READY):
Practically the same as the HV battery voltage
|
-
|
VH Voltage
|
High voltage after it is boosted
|
Min.: 0.0 V, Max.: 1000.0 V
|
Engine revving up with shift lever in P:
After boosted voltage to below 650 V
|
-
|
Boosting Converter PWM Duty
|
Boost converter PWM duty
|
Min.: 0 %, Max.: 100 %
|
-
|
-
|
Boosting Converter Control Mode
|
Boost converter control mode
|
Min.: 0, Max.: 255
|
-
|
-
|
Boosting Converter Carrier Frequency
|
Boost converter signal carrier frequency
|
9.55 kHz, 9.13 kHz, 8.71 kHz, 8.29 kHz, 7.87 kHz, 7.45 kHz, 4.8 kHz
|
-
|
-
|
Boosting Converter Shut Down Signal
|
Boost converter shutdown signal
|
Min.: 0, Max.: 255
|
-
|
-
|
Generate Request Torque
|
Generator (MG1) torque request value
|
Min.: -4096.000 Nm, Max.: 4095.875 Nm
|
-
|
-
|
Shift Position
|
Shift position
|
P / R / N / D / B
|
Matches currently selected shift state:
P, R, N or D
|
-
|
Motor Temperature
|
Motor (MG2) temperature
|
Min.: -40°C (-40°F), Max.: 215°C (419°F)
|
Vehicle left for 1 day at an ambient temperature of 25°C (77°F):
25°C (77°F)
Changes according to vehicle condition and ambient temperature
|
-
|
Generator Temperature
|
Generator (MG1) temperature
|
Min.: -40°C (-40°F), Max.: 215°C (419°F)
|
Vehicle left for 1 day at an ambient temperature of 25°C (77°F):
25°C (77°F)
Changes according to vehicle condition and ambient temperature
|
-
|
Short Wave Highest Value
|
Waveform voltage in abnormal insulation detection circuit in battery voltage sensor
|
Min.: 0.00 V, Max.: 4.98 V
|
-
|
-
|
Fail Safe Mode
|
Fail safe mode
|
Min.: -128, Max.: 127
|
-
|
-
|
Accelerator Position
|
Accelerator position
|
Min.: 0.0 %, Max.: 100.0 %
|
Accelerator pedal depressed:
Changes with accelerator pedal pressure
|
-
|
WIN Control Limit Power
|
Power flowing to HV battery (Charging)
(detected at battery voltage sensor)
|
Min.: -327.68 kW, Max.: 327.67 kW
|
-38.76 kW or more
|
-
|
WOUT Control Limit Power
|
Power flowing from HV battery (Discharging)
(detected at battery voltage sensor)
|
Min.: -327.68 kW, Max.: 327.67 kW
|
25.50 kW or less
|
-
|
Engine Control Mode
|
Engine control mode
|
Stop, Stop process, Startup process or Running
|
-
|
-
|
Emergency Shutdown Signal
|
Inverter emergency shutdown
|
ON or OFF
|
Inverter emergency shutdown:
ON
Normal:
OFF
|
-
|
Ready ON Status
|
State of system (READY)
|
ON or OFF
|
Ignition switch ON (READY):
ON
|
-
|
SMR Status
|
System main relay status
|
ON or OFF
|
Ignition switch ON (READY):
ON
|
-
|
Generator Resolver Offset Complete Status
|
Generator resolver learning complete status
|
ON or OFF
|
Generator resolver learning has been completed:
ON
|
-
|
Generator Inverter High Current(GFINV)
|
Generator (MG1) inverter high current
|
ON or OFF
|
Normal:
OFF
|
-
|
Generator Inverter Shut Down Status
|
Generator (MG1) inverter shutdown status
|
ON or OFF
|
Generator inverter shutdown:
ON
Normal:
OFF
|
-
|
Motor Resolver Offset Complete Status
|
Motor resolver learning complete status
|
ON or OFF
|
Motor resolver learning has been completed:
ON
|
-
|
PTC Heater Activate Permission Status/Prohibition Signal(IDH)
|
PTC heater
|
ON or OFF
|
-
|
-
|
DC/DC Converter Terminate Signal
|
DC/DC converter stop request signal
|
ON or OFF
|
Normal:
OFF
|
-
|
Motor Inverter High Current(MFINV)
|
Motor inverter high current
|
ON or OFF
|
Normal:
OFF
|
-
|
Motor Inverter Shut Down Status
|
Motor inverter shutdown status
|
ON or OFF
|
Motor inverter shutdown:
ON
Normal:
OFF
|
-
|
Inverter Input High Voltage(OVH)
|
Inverter input high voltage
|
ON or OFF
|
Normal:
OFF
|
-
|
Boosting Converter Input High Voltage(OVL)
|
Boost converter input high voltage
|
ON or OFF
|
Normal:
OFF
|
-
|
Boosting Converter Input High Current(CFINV)
|
Boost converter input high current
|
ON or OFF
|
Normal:
OFF
|
-
|
Boosting Converter Shut Down Status
|
Boost converter shutdown status
|
ON or OFF
|
Boost converter shutdown:
ON
Normal:
OFF
|
-
|
Airbag Collision Detection History
|
Detection history of airbag collision
|
ON or OFF
|
-
|
-
|
Battery Discharge Control Circuit Monitor Voltage
|
Voltage of battery discharge control circuit monitor
|
Min.: 0.000000 V, Max.: 4.980468 V
|
-
|
-
|
Battery Discharge Control Circuit Power Switch
|
Ignition switch condition of battery discharge control circuit
|
ON or OFF
|
-
|
-
|
Total Distance Traveled
|
Drive total distance
|
Min.: 0 km (0 mile), Max.: 16777215 km (10425361 mile)
|
-
|
-
|
Total Distance Traveled - Unit
|
Drive total distance unit
|
km or mile
|
-
|
-
|
Rear Motor Generate Request Torque
|
Rear motor (MGR) torque request value
|
Min.: -4096.000 Nm, Max.: 4095.875 Nm
|
-
|
-
|
Generator Inverter Temperature
|
Generator inverter temperature
|
Min.: 0°C (32°F), Max.: 150°C (302°F)
|
Vehicle left for 1 day at an ambient temperature of 25°C (77°F):
8 to 35°C (46.4 to 95°F)
While driving with an ambient temperature of 25°C (77°F):
25 to 120°C (77 to 248°F)
|
|