Last Modified: 01-30-2024 |
6.11:8.1.0 |
Doc ID: RM100000001OQZK |
Model Year Start: 2020 |
Model: RAV4 HV |
Prod Date Range: [06/2020 -
] |
Title: HYBRID / BATTERY CONTROL: MOTOR GENERATOR CONTROL SYSTEM (for LITHIUM-ION BATTERY): P0A1112,P0A1114; DC/DC Converter Enable Circuit Short to Battery; 2020 - 2024 MY RAV4 HV [06/2020 - ] |
DTC
|
P0A1112
|
DC/DC Converter Enable Circuit Short to Battery
|
DTC
|
P0A1114
|
DC/DC Converter Enable Circuit Short to Ground or Open
|
DESCRIPTION
Refer to the description for DTC P1CCC96.
Click here
The motor generator control ECU sends a signal to the DC/DC converter to prohibit its control and receives signals indicating a normal or abnormal (below 11 V) condition of the 12 V charging system from the DC/DC converter via the NODD signal line.
If the vehicle is being driven with an inoperative DC/DC converter, the voltage of the auxiliary battery will drop, which will prevent the continued operation of the vehicle. Therefore, the motor generator control ECU monitors the operation of the DC/DC converter and alerts the driver if it detects a malfunction.
DTC No.
|
Detection Item
|
DTC Detection Condition
|
Trouble Area
|
MIL
|
Warning Indicate
|
P0A1112
|
DC/DC Converter Enable Circuit Short to Battery
|
Short to +B detected in DC/DC converter NODD signal line
(1 trip detection logic)
|
-
Wire harness or connector
-
Inverter with converter assembly
|
Does not come on
|
Master Warning:
Comes on
|
P0A1114
|
DC/DC Converter Enable Circuit Short to Ground or Open
|
Open or short to ground detected in DC/DC converter NODD signal line
(1 trip detection logic)
|
-
Wire harness or connector
-
Inverter with converter assembly
|
Does not come on
|
Master Warning:
Comes on
|
CONFIRMATION DRIVING PATTERN
HINT:
After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.
Click here
-
Connect the Techstream to the DLC3.
-
Turn the ignition switch to ON and turn the Techstream on.
-
Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
-
Turn the ignition switch off and wait for 2 minutes or more.
-
Turn the ignition switch to ON and turn the Techstream on.
-
With ignition switch ON and wait for 10 seconds or more.
-
Enter the following menus: Powertrain / Motor Generator / Utility / All Readiness.
-
Check the DTC judgment result.
HINT:
-
If the judgment result shows NORMAL, the system is normal.
-
If the judgment result shows ABNORMAL, the system has a malfunction.
-
If the judgment result shows INCOMPLETE, perform driving pattern again.
WIRING DIAGRAM
CAUTION / NOTICE / HINT
CAUTION:
NOTICE:
After turning the ignition switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.
Click here
HINT:
If the NODD signal line is open, DC/DC converter control will be prohibited and the auxiliary battery voltage will be approximately 12 V or less.
PROCEDURE
1.
|
CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)
|
Click here
Result
|
Proceed to
|
OK
|
A
|
NG (The connector is not connected securely.)
|
B
|
NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.)
|
C
|
B |
|
CONNECT SECURELY
|
C |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR
|
A
|
|
|
2.
|
CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - IGCT RELAY)
|
CAUTION:
Be sure to wear insulated gloves.
(a) Check that the service plug grip is not installed.
NOTICE:
After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
(b) Disconnect the A87 inverter with converter assembly connector.
(c) Remove the IGCT relay from the No. 3 relay block and junction block assembly.
(d) Measure the resistance according to the value(s) in the table below.
*1
|
No. 3 Relay Block and Junction Block Assembly
|
*2
|
IGCT Relay
|
*a
|
Front view of wire harness connector
(to Inverter with Converter Assembly)
|
-
|
-
|
Standard Resistance:
Tester Connection
|
Condition
|
Specified Condition
|
A87-26 (IGCT) - 5 (IGCT relay)
|
Ignition switch off
|
Below 1 Ω
|
(e) Install the IGCT relay.
(f) Reconnect the A87 inverter with converter assembly connector.
NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR
|
|