                           Last Modified: 05-08-2025 | 
                        6.11:8.1.0  | 
                        
                           Doc ID: RM100000001OR0L | 
                      
                     
                        | 
                           Model Year Start: 2020 | 
                        
                           Model: RAV4 HV | 
                        
                           Prod Date Range: [06/2020 -                    
                                       ] | 
                      
                     
                        | 
                           Title: HYBRID / BATTERY CONTROL: MOTOR GENERATOR CONTROL SYSTEM (for LITHIUM-ION BATTERY): P0E5111,P0E5115,P0E511F; DC/DC Converter Current Sensor Circuit Short to Ground; 2020 - 2025 MY RAV4 HV [06/2020 -        ] | 
                      
                   
                  
                     
                        
                           | 
                               DTC 
                            | 
                           
                               P0E5111 
                            | 
                           
                               DC/DC Converter Current Sensor Circuit Short to Ground 
                            | 
                         
                     
                   
                  
                     
                        
                           | 
                               DTC 
                            | 
                           
                               P0E5115 
                            | 
                           
                               DC/DC Converter Current Sensor Circuit Short to Battery or Open 
                            | 
                         
                     
                   
                  
                     
                        
                           | 
                               DTC 
                            | 
                           
                               P0E511F 
                            | 
                           
                               DC/DC Converter Current Sensor Circuit Intermittent 
                            | 
                         
                     
                   
                   
                  DESCRIPTION
                  
                     
                        
                        
                        
                        
                        
                        
                     
                     
                        
                           | 
                               DTC No. 
                            | 
                           
                               Detection Item 
                            | 
                           
                               DTC Detection Condition 
                            | 
                           
                               Trouble Area 
                            | 
                           
                               MIL 
                            | 
                           
                               Warning Indicate 
                            | 
                         
                     
                     
                        
                           | 
                               P0E5111 
                            | 
                           
                               DC/DC Converter Current Sensor Circuit Short to Ground 
                            | 
                           
                               Short to ground detected in reactor current sensor circuit 
                              (1 trip detection logic) 
                            | 
                           
                               Inverter with converter assembly 
                            | 
                           
                               Comes on 
                            | 
                           
                               Master Warning: 
                              Comes on 
                            | 
                         
                        
                           | 
                               P0E5115 
                            | 
                           
                               DC/DC Converter Current Sensor Circuit Short to Battery or Open 
                            | 
                           
                               Open or short to +B detected in reactor current sensor circuit 
                              (1 trip detection logic) 
                            | 
                           
                               Inverter with converter assembly 
                            | 
                           
                               Comes on 
                            | 
                           
                               Master Warning: 
                              Comes on 
                            | 
                         
                        
                           | 
                               P0E511F 
                            | 
                           
                               DC/DC Converter Current Sensor Circuit Intermittent 
                            | 
                           
                               Short to ground, open or short to +B detected in reactor current sensor circuit when DTC P0C7917, P0D3319, P1C5D19, P1C5F19 or P1C5E19 is stored. 
                              (1 trip detection logic) 
                            | 
                           
                               Inverter with converter assembly 
                            | 
                           
                               Does not come on 
                            | 
                           
                               Master Warning: 
                              Does not come on 
                            | 
                         
                     
                   
                  Related Data List
                  
                     
                        
                        
                     
                     
                        
                           | 
                               DTC No. 
                            | 
                           
                               Data List 
                            | 
                         
                     
                     
                        
                           | 
                               P0E5111 
                              P0E5115 
                              P0E511F 
                            | 
                           
                               Inverter Input Current 
                            | 
                         
                     
                   
                   
                  MONITOR DESCRIPTION
                  If the motor generator control ECU detects an open or short in the DC/DC converter current sensor circuit, it will illuminate the MIL and store a DTC. 
                   
                  MONITOR STRATEGY
                  
                     
                        
                        
                     
                     
                        
                           | 
                               Related DTCs 
                            | 
                           
                               P0E53 (INF P0E5111): DC/DC Converter Current Sensor Range check (Low voltage) 
                              P0E54 (INF P0E5115): DC/DC Converter Current Sensor Range check (High voltage) 
                            | 
                         
                        
                           | 
                               Required sensors/components 
                            | 
                           
                               DC/DC converter current sensor 
                            | 
                         
                        
                           | 
                               Frequency of operation 
                            | 
                           
                               Continuous 
                            | 
                         
                        
                           | 
                               Duration 
                            | 
                           
                               TMC's intellectual property 
                            | 
                         
                        
                           | 
                               MIL operation 
                            | 
                           
                               Immediately 
                            | 
                         
                        
                           | 
                               Sequence of operation 
                            | 
                           
                               None 
                            | 
                         
                     
                   
                   
                  TYPICAL ENABLING CONDITIONS
                  
                     
                        
                        
                     
                     
                        
                           | 
                               The monitor will run whenever the following DTCs are not stored 
                            | 
                           
                               TMC's intellectual property 
                            | 
                         
                        
                           | 
                               Other conditions belong to TMC's intellectual property 
                            | 
                           
                               - 
                            | 
                         
                     
                   
                   
                  TYPICAL MALFUNCTION THRESHOLDS
                  
                     
                        
                        
                     
                     
                        
                           | 
                               TMC's intellectual property 
                            | 
                           
                               - 
                            | 
                         
                     
                   
                   
                  COMPONENT OPERATING RANGE
                  
                     
                        
                        
                     
                     
                        
                           | 
                               Motor generator control ECU 
                            | 
                           
                               DTC P0E53 (INF P0E5111) is not detected 
                              DTC P0E54 (INF P0E5115) is not detected 
                            | 
                         
                     
                   
                   
                  CONFIRMATION DRIVING PATTERN
                  
                     HINT: 
                     
                        - 
After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.
Click here
                                 
                                    
                                        
                                    
                                 
                              
                            
                         
                        - 
When clearing the permanent DTCs, refer to the "CLEAR PERMANENT DTC" procedure.
Click here
                                 
                                    
                                        
                                    
                                 
                              
                            
                         
                      
                   
                  
                     
                        - 
Connect the Techstream to the DLC3.
 
                        - 
Turn the ignition switch to ON and turn the Techstream on.
 
                        - 
Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
 
                        - 
Turn the ignition switch off and wait for 2 minutes or more.
 
                        - 
Turn the ignition switch to ON and turn the Techstream on.
 
                        - 
With ignition switch ON and wait for 5 seconds or more. [*1]
HINT: 
                           [*1]: Normal judgment procedure. 
                           The normal judgment procedure is used to complete DTC judgment and also used when clearing permanent DTCs. 
                         
                        - 
Enter the following menus: Powertrain / Motor Generator / Utility / All Readiness.
 
                        - 
Check the DTC judgment result.
                              HINT: 
                              
                                 - 
If the judgment result shows NORMAL, the system is normal.
 
                                 - 
If the judgment result shows ABNORMAL, the system has a malfunction.
 
                                 - 
If the judgment result shows INCOMPLETE, perform the normal judgment procedure again.
 
                               
                            
                         
                      
                   
                   
                  CAUTION / NOTICE / HINT
                  
                     CAUTION: 
                      
                     
                   
                  NOTICE: 
                  After turning the ignition switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work. 
                  Click here
                        
                           
                               
                           
                        
                     
                   
                   
                  PROCEDURE
                   
                  
                     
                        
                           | 
                               1.  
                            | 
                           
                               REPLACE INVERTER WITH CONVERTER ASSEMBLY 
                            | 
                         
                     
                   
                  Click here
                        
                           
                               
                           
                        
                        
                           
                               
                           
                        
                        
                           
                               
                           
                        
                        
                           
                               
                           
                        
                        
                           
                               
                           
                        
                     
                   
                  
                     
                        
                           | NEXT | 
                           
                               
                            | 
                           
                               COMPLETED 
                            | 
                         
                     
                   
                  
                |