P1C2C1C
|
Drive Motor "B" Control Module AD Converter Circuit Voltage Out of Range
|
Motor generator control ECU internal malfunction
(1 trip detection logic)
|
Inverter with converter assembly
|
Comes on
|
Master Warning:
Comes on
|
P1C2C49
|
Drive Motor "B" Control Module AD Converter Circuit Internal Electronic Failure
|
Motor generator control ECU internal malfunction
(1 trip detection logic)
|
Inverter with converter assembly
|
Comes on
|
Master Warning:
Comes on
|
P1C631F
|
Drive Motor "B" Control Module Offset Power Circuit Intermittent
|
Motor generator control ECU internal malfunction detected when DTC P0C7917, P0D3319, P1C5D19, P1C5F19 or P1C5E19 is stored.
(1 trip detection logic)
|
Inverter with converter assembly
|
Does not come on
|
Master Warning:
Does not come on
|
P262C1C
|
Drive Motor "B" Control Module Offset Power Circuit Voltage Out of Range
|
Motor generator control ECU internal malfunction
(1 trip detection logic)
|
Inverter with converter assembly
|
Comes on
|
Master Warning:
Comes on
|
P310B1F
|
Communication Error from Drive Motor "A" to Drive Motor "B" Circuit Intermittent
|
Communication error (circuit intermittent from motor to rear motor) detected when DTC P0C7917, P0D3319, P1C5D19, P1C5F19 or P1C5E19 is stored.
(1 trip detection logic)
|
Inverter with converter assembly
|
Does not come on
|
Master Warning:
Does not come on
|
P310B83
|
Communication Error from Drive Motor "A" to Drive Motor "B" Value of Signal Protection Calculation Incorrect
|
Motor generator control ECU internal malfunction
(1 trip detection logic)
|
Inverter with converter assembly
|
Comes on
|
Master Warning:
Comes on
|
P310B86
|
Communication Error from Drive Motor "A" to Drive Motor "B" Signal (Some Circuit Quantity, Reported via Serial Data) Invalid
|
Motor generator control ECU internal malfunction
(1 trip detection logic)
|
Inverter with converter assembly
|
Comes on
|
Master Warning:
Comes on
|
P310B87
|
Communication Error from Drive Motor "A" to Drive Motor "B" Missing Message
|
Motor generator control ECU internal malfunction
(1 trip detection logic)
|
Inverter with converter assembly
|
Comes on
|
Master Warning:
Comes on
|
P32CF1F
|
Lost Communication between Drive Motor "A" and "B" (Drive Motor "B") Circuit Intermittent
|
Communication error (circuit intermittent from generator to rear motor) detected when DTC P0C7917, P0D3319, P1C5D19, P1C5F19 or P1C5E19 is stored.
(1 trip detection logic)
|
Inverter with converter assembly
|
Does not come on
|
Master Warning:
Does not come on
|
P32CF83
|
Lost Communication between Drive Motor "A" and "B" (Drive Motor "B") Value of Signal Protection Calculation Incorrect
|
Motor generator control ECU internal malfunction
(1 trip detection logic)
|
Inverter with converter assembly
|
Comes on
|
Master Warning:
Comes on
|
P32CF86
|
Lost Communication between Drive Motor "A" and "B" (Drive Motor "B") Signal (Some Circuit Quantity, Reported via Serial Data) Invalid
|
Motor generator control ECU internal malfunction
(1 trip detection logic)
|
Inverter with converter assembly
|
Comes on
|
Master Warning:
Comes on
|
P32CF87
|
Lost Communication between Drive Motor "A" and "B" (Drive Motor "B") Missing Message
|
Motor generator control ECU internal malfunction
(1 trip detection logic)
|
Inverter with converter assembly
|
Comes on
|
Master Warning:
Comes on
|