                               Vehicle Speed 
                            | 
                           
                               Vehicle speed 
                            | 
                           
                               Min.: 0 km/h (0 mph), Max.: 255 km/h (158 mph) 
                            | 
                        
                        
                           | 
                               Target Engine Power 
                            | 
                           
                               Target engine power 
                            | 
                           
                               Min.: 0 W, Max.: 655350 W 
                            | 
                        
                        
                           | 
                               Execute Engine Power 
                            | 
                           
                               Execute engine power 
                            | 
                           
                               Min.: 0 W, Max.: 655350 W 
                            | 
                        
                        
                           | 
                               Target Engine Revolution 
                            | 
                           
                               Target engine revolution 
                            | 
                           
                               Min.: 0 rpm, Max.: 32767 rpm 
                            | 
                        
                        
                           | 
                               Engine Speed 
                            | 
                           
                               Engine speed 
                            | 
                           
                               - 
                            | 
                        
                        
                           | 
                               Calculate Load 
                            | 
                           
                               Calculate load 
                            | 
                           
                               Min.: 0.00%, Max.: 100.00% 
                            | 
                        
                        
                           | 
                               Coolant Temperature 
                            | 
                           
                               Engine coolant temperature 
                            | 
                           
                               Min.: -40°C (-40°F), Max.: 215°C (419°F) 
                            | 
                        
                        
                           | 
                               Starter Switch Signal 
                            | 
                           
                               Starter ON / OFF signal 
                            | 
                           
                               ON or OFF 
                            | 
                        
                        
                           | 
                               Engine Idling Request 
                            | 
                           
                               Engine idling request 
                            | 
                           
                               ON or OFF 
                            | 
                        
                        
                           | 
                               Engine Start Request (A/C) 
                            | 
                           
                               Engine idling request from air conditioning amplifier assembly 
                            | 
                           
                               ON or OFF 
                            | 
                        
                        
                           | 
                               Engine Start Request (Engine Warm-up) 
                            | 
                           
                               Engine idling request to warm up engine 
                            | 
                           
                               ON or OFF 
                            | 
                        
                        
                           | 
                               Engine Start Request (Hybrid/EV Battery Charging) 
                            | 
                           
                               Engine idling request to charge HV battery 
                            | 
                           
                               ON or OFF 
                            | 
                        
                        
                           | 
                               Engine Mode 
                            | 
                           
                               Engine status 
                            | 
                           
                               Stop / Stop Process / Startup Process / Running 
                            | 
                        
                        
                           | 
                               Engine Run Time 
                            | 
                           
                               Elapsed time after starting engine 
                            | 
                           
                               Min.: 0 sec, Max.: 65535 sec 
                            | 
                        
                        
                           | 
                               Engine Stop Request 
                            | 
                           
                               Engine stop request 
                            | 
                           
                               ON or OFF 
                            | 
                        
                        
                           | 
                               Engine Stop F/C Status 
                            | 
                           
                               Engine fuel cut status 
                            | 
                           
                               ON or OFF 
                            | 
                        
                        
                           | 
                               Lack of Fuel 
                            | 
                           
                               Lack of fuel 
                            | 
                           
                               ON or OFF 
                            | 
                        
                        
                           | 
                               Accelerator Position 
                            | 
                           
                               Accelerator pedal depressed angle 
                            | 
                           
                               Min.: 0.0%, Max.: 100.0% 
                            | 
                        
                        
                           | 
                               Accelerator Pedal Status 
                            | 
                           
                               Accelerator pedal status 
                            | 
                           
                               ON or OFF 
                            | 
                        
                        
                           | 
                               Accelerator Position Sensor No.1 Voltage % 
                            | 
                           
                               Accelerator pedal position sensor No. 1 
                            | 
                           
                               Min.: 0.00%, Max.: 100.00% 
                            | 
                        
                        
                           | 
                               Accelerator Position Sensor No.2 Voltage % 
                            | 
                           
                               Accelerator pedal position sensor No. 2 
                            | 
                           
                               Min.: 0.00%, Max.: 100.00% 
                            | 
                        
                        
                           | 
                               Throttle Position Sensor No.1 Voltage % 
                            | 
                           
                               Throttle valve angle 
                            | 
                           
                               Min.: 0.00%, Max.: 100.00% 
                            | 
                        
                        
                           | 
                               Master Cylinder Control Torque 
                            | 
                           
                               Braking torque equivalent to master cylinder brake fluid pressure 
                              (Total braking torque) 
                            | 
                           
                               - 
                            | 
                        
                        
                           | 
                               Brake Cancel Switch 
                            | 
                           
                               Brake pedal status 
                            | 
                           
                               ON or OFF 
                            | 
                        
                        
                           | 
                               Shift Position 
                            | 
                           
                               Current shift state 
                            | 
                           
                               P / R / N / D / B 
                            | 
                        
                        
                           | 
                               Shift Position (Meter) 
                            | 
                           
                               Shift position of meter display 
                            | 
                           
                               Not Displayed / P / R / N / D / B 
                            | 
                        
                        
                           | 
                               Shift Switch Status (N,P Position) 
                            | 
                           
                               Shift position status (N or P position) 
                            | 
                           
                               ON or OFF 
                            | 
                        
                        
                           | 
                               Shift Position Sensor (PNB) 
                            | 
                           
                               Shift position sensor 
                            | 
                           
                               ON or OFF 
                            | 
                        
                        
                           | 
                               Shift Position Sensor (PR) 
                            | 
                           
                               Shift position sensor 
                            | 
                           
                               ON or OFF 
                            | 
                        
                        
                           | 
                               Shift Position Sensor (DB1) 
                            | 
                           
                               Shift position sensor 
                            | 
                           
                               ON or OFF 
                            | 
                        
                        
                           | 
                               Shift Position Sensor (DB2) 
                            | 
                           
                               Shift position sensor 
                            | 
                           
                               ON or OFF 
                            | 
                        
                        
                           | 
                               Shift Position Sensor (N) 
                            | 
                           
                               Shift position sensor 
                            | 
                           
                               ON or OFF 
                            | 
                        
                        
                           | 
                               Shift Position Sensor (R) 
                            | 
                           
                               Shift position sensor 
                            | 
                           
                               ON or OFF 
                            | 
                        
                        
                           | 
                               Shift Position Sensor (P) 
                            | 
                           
                               Shift position sensor 
                            | 
                           
                               ON or OFF 
                            | 
                        
                        
                           | 
                               Shift Lock Release Request 
                            | 
                           
                               Shift lock release request 
                            | 
                           
                               ON or OFF 
                            | 
                        
                        
                           | 
                               Sports Shift Position 
                            | 
                           
                               Sports shift position 
                            | 
                           
                               Min.: 0, Max.: 255 
                            | 
                        
                        
                           | 
                               Sports Shift UP Signal 
                            | 
                           
                               Sports shift UP signal 
                            | 
                           
                               ON or OFF 
                            | 
                        
                        
                           | 
                               Sports Shift DOWN Signal 
                            | 
                           
                               Sports Shift DOWN Signal 
                            | 
                           
                               ON or OFF 
                            | 
                        
                        
                           | 
                               Transaxle Oil Temperature 
                            | 
                           
                               Hybrid vehicle transaxle oil temperature 
                            | 
                           
                               Min.: -40°C (-40°F), Max.: 215°C (419°F) 
                            | 
                        
                        
                           | 
                               Transaxle Oil Temperature Sensor Voltage 
                            | 
                           
                               Hybrid vehicle transaxle oil temperature sensor voltage 
                            | 
                           
                               Min: 0.00 V, Max: 4.99 V 
                            | 
                        
                        
                           | 
                               FR Wheel Speed 
                            | 
                           
                               Front wheel speed RH 
                            | 
                           
                               Min.: 0.00 km/h (0 mph), Max.: 327.67 km/h (204 mph) 
                            | 
                        
                        
                           | 
                               FL Wheel Speed 
                            | 
                           
                               Front wheel speed LH 
                            | 
                           
                               Min.: 0.00 km/h (0 mph), Max.: 327.67 km/h (204 mph) 
                            | 
                        
                        
                           | 
                               RR Wheel Speed 
                            | 
                           
                               Rear wheel speed RH 
                            | 
                           
                               Min.: 0.00 km/h (0 mph), Max.: 327.67 km/h (204 mph) 
                            | 
                        
                        
                           | 
                               RL Wheel Speed 
                            | 
                           
                               Rear wheel speed LH 
                            | 
                           
                               Min.: 0.00 km/h (0 mph), Max.: 327.67 km/h (204 mph) 
                            | 
                        
                        
                           | 
                               Steering Angle 
                            | 
                           
                               Steering angle value 
                              (counterclockwise is positive) 
                            | 
                           
                               - 
                            | 
                        
                        
                           | 
                               Forward and Rearward G 
                            | 
                           
                               Forward and rearward G value 
                            | 
                           
                               -13.107 to 13.106 m/s2 
                            | 
                        
                        
                           | 
                               Lateral G 
                            | 
                           
                               Lateral G value 
                            | 
                           
                               -13.107 to 13.106 m/s2 
                            | 
                        
                        
                           | 
                               Yaw Rate Value 
                            | 
                           
                               Yaw rate value 
                            | 
                           
                               -128.0 to 127.9 deg/s 
                            | 
                        
                        
                           | 
                               Atmospheric Pressure 
                            | 
                           
                               Atmospheric pressure 
                            | 
                           
                               Min.: 0 kPa, Max.: 255 kPa 
                            | 
                        
                        
                           | 
                               Intake Manifold Absolute Pressure 
                            | 
                           
                               Intake manifold pressure of engine 
                            | 
                           
                               Min.: 0.00 kPa, Max.: 255.00 kPa 
                            | 
                        
                        
                           | 
                               Ambient Temperature 
                            | 
                           
                               Ambient air temperature 
                            | 
                           
                               Min.: -40°C (-40°F), Max.: 215°C (419°F) 
                            | 
                        
                        
                           | 
                               Intake Air Temperature 
                            | 
                           
                               Engine intake air temperature 
                            | 
                           
                               Min.: -40°C (-40°F), Max.: 215°C (419°F) 
                            | 
                        
                        
                           | 
                               BATT Voltage 
                            | 
                           
                               Auxiliary battery voltage 
                              (Battery voltage sensor power source voltage) 
                            | 
                           
                               Min.: 0.00 V, Max.: 16.00 V 
                            | 
                        
                        
                           | 
                               Smoothed Value of BATT Voltage 
                            | 
                           
                               Smoothed value of auxiliary battery voltage 
                            | 
                           
                               Min.: 0.000 V, Max.: 16.000 V 
                            | 
                        
                        
                           | 
                               Warmup Cycle Cleared DTC 
                            | 
                           
                               The number of times the engine is warmed up after clearing DTCs 
                            | 
                           
                               Min.: 0, Max.: 255 
                            | 
                        
                        
                           | 
                               Distance from DTC Cleared 
                            | 
                           
                               Drive distance after clearing DTCs 
                            | 
                           
                               Min.: 0 km (0 mile), Max.: 65535 km (40723 mile) 
                            | 
                        
                        
                           | 
                               Time after DTC Cleared 
                            | 
                           
                               Elapsed time after clearing DTCs 
                            | 
                           
                               Min.: 0 min, Max.: 65535 min 
                            | 
                        
                        
                           | 
                               Running Time from MIL ON 
                            | 
                           
                               Running time from MIL on 
                            | 
                           
                               Min.: 0 min, Max.: 65535 min 
                            | 
                        
                        
                           | 
                               Total Distance Traveled 
                            | 
                           
                               Drive total distance 
                            | 
                           
                               Min.: 0, Max.: 16777215 
                            | 
                        
                        
                           | 
                               Total Distance Traveled - Unit 
                            | 
                           
                               Drive total distance unit 
                            | 
                           
                               km or mile 
                            | 
                        
                        
                           | 
                               MIL ON Run Distance 
                            | 
                           
                               Drive distance from MIL on 
                            | 
                           
                               Min.: 0 km (0 mile), Max.: 65535 km (40723 mile) 
                            | 
                        
                        
                           | 
                               IGB Signal Status 
                            | 
                           
                               IGB signal status 
                            | 
                           
                               ON or OFF 
                            | 
                        
                        
                           | 
                               IG2 Signal Status 
                            | 
                           
                               IG2 signal status 
                            | 
                           
                               ON or OFF 
                            | 
                        
                        
                           | 
                               Ready Signal 
                            | 
                           
                               Ready signal status 
                            | 
                           
                               ON or OFF 
                            | 
                        
                        
                           | 
                               HV/EV Activate Condition 
                            | 
                           
                               Hybrid vehicle control system power source mode status 
                            | 
                           
                               Normal / Remote Air Control System / Remote 
                            | 
                        
                        
                           | 
                               MG Activate Condition 
                            | 
                           
                               Motor generator control system status 
                            | 
                           
                               ON or OFF 
                            | 
                        
                        
                           | 
                               Request Torque for Rear Side 
                            | 
                           
                               Requested rear motor (MGR) torque 
                            | 
                           
                               Min.: -32768 Nm, Max.: 32767 Nm 
                            | 
                        
                        
                           | 
                               DSS Control Status 
                            | 
                           
                               Control status of DSS (Driving Support System) 
                            | 
                           
                               Not Control / Available / Unavailable / Disable 
                            | 
                        
                        
                           | 
                               Generate Torque (Request from DSS) 
                            | 
                           
                               Generated drive torque requested from DSS (Driving Support System) 
                            | 
                           
                               Min.: -4096.00 Nm, Max.: 4095.87 Nm 
                            | 
                        
                        
                           | 
                               Primary Driving Force Adjustment Result 
                            | 
                           
                               Result of adjustment between drive force of DSS (Driving Support System) and drive force requested by accelerator pedal operation 
                            | 
                           
                               Accelerator / DSS 
                            | 
                        
                        
                           | 
                               SMRG Status 
                            | 
                           
                               Operating state of SMRG 
                              (primary circuit monitor) 
                            | 
                           
                               ON or OFF 
                            | 
                        
                        
                           | 
                               SMRG Control Status 
                            | 
                           
                               Commanded state of SMRG 
                            | 
                           
                               ON or OFF 
                            | 
                        
                        
                           | 
                               SMRB Status 
                            | 
                           
                               Operating state of SMRB 
                              (primary circuit monitor) 
                            | 
                           
                               ON or OFF 
                            | 
                        
                        
                           | 
                               SMRB Control Status 
                            | 
                           
                               Commanded state of SMRB 
                            | 
                           
                               ON or OFF 
                            | 
                        
                        
                           | 
                               SMRP Status 
                            | 
                           
                               Operating state of SMRP 
                              (primary circuit monitor) 
                            | 
                           
                               ON or OFF 
                            | 
                        
                        
                           | 
                               SMRP Control Status 
                            | 
                           
                               Commanded state of SMRP 
                            | 
                           
                               ON or OFF 
                            | 
                        
                        
                           | 
                               Voltage Deviation between before Boosting and after Boosting during SMR Precharge 
                            | 
                           
                               Difference in voltage before boosting and after boosting during system main relay precharge 
                            | 
                           
                               Min.: -3276.8 V, Max.: 3276.7 V 
                            | 
                        
                        
                           | 
                               A/C Consumption Power 
                            | 
                           
                               A/C consumption power 
                            | 
                           
                               Min.: 0.00 kW, Max.: 12.75 kW 
                            | 
                        
                        
                           | 
                               EV Mode 
                            | 
                           
                               EV mode transition availability 
                            | 
                           
                               ON or OFF 
                            | 
                        
                        
                           | 
                               EV Mode Switch 
                            | 
                           
                               EV mode switch (integration control and panel assembly) condition 
                            | 
                           
                               ON or OFF 
                            | 
                        
                        
                           | 
                               Sport Mode Switch 
                            | 
                           
                               SPORT mode switch (integration control and panel assembly) condition 
                            | 
                           
                               ON or OFF 
                            | 
                        
                        
                           | 
                               M or S Shift Position Signal 
                            | 
                           
                               Shift position sensor 
                            | 
                           
                               ON or OFF 
                            | 
                        
                        
                           | 
                               Normal Mode Switch 
                            | 
                           
                               NORMAL mode switch (integration control and panel assembly) condition 
                            | 
                           
                               ON or OFF 
                            | 
                        
                        
                           | 
                               Inter Lock Switch 
                            | 
                           
                               Interlock switch condition 
                            | 
                           
                               ON or OFF 
                            | 
                        
                        
                           | 
                               Inter Lock Switch (MG) 
                            | 
                           
                               Interlock switch condition 
                            | 
                           
                               ON or OFF 
                            | 
                        
                        
                           | 
                               Stop Light Switch 
                            | 
                           
                               Stop light switch assembly condition 
                            | 
                           
                               ON or OFF 
                            | 
                        
                        
                           | 
                               Back Up Light Relay 
                            | 
                           
                               Back up light switch condition 
                            | 
                           
                               ON or OFF 
                            | 
                        
                        
                           | 
                               VSC/TRC OFF Switch 
                            | 
                           
                               VSC condition 
                            | 
                           
                               OFF / TRC OFF Mode / TRC/VSC OFF Mode 
                            | 
                        
                        
                           | 
                               Auto LSD Switch 
                            | 
                           
                               TRAIL mode switch (integration control and panel assembly) condition 
                            | 
                           
                               ON or OFF 
                            | 
                        
                        
                           | 
                               Airbag Status (Collision) (CAN) 
                            | 
                           
                               Airbag sensor assembly collision detection 
                              (CAN) 
                            | 
                           
                               Normal / Collision from Back / Airbag Circuit Abnormal / Safing / Collision from Front or Side 
                            | 
                        
                        
                           | 
                               Crank Position 
                            | 
                           
                               Crankshaft position 
                            | 
                           
                               Min.: -128 deg (CA), Max.: 127 deg (CA) 
                            | 
                        
                        
                           | 
                               TC Terminal 
                            | 
                           
                               TC terminal state 
                            | 
                           
                               ON or OFF 
                            | 
                        
                        
                           | 
                               Generator Revolution 
                            | 
                           
                               Generator (MG1) speed (detected by resolver sensor) 
                            | 
                           
                               Min.: -32768 rpm, Max.: 32767 rpm 
                            | 
                        
                        
                           | 
                               Target Generator Torque 
                            | 
                           
                               Generator (MG1) torque request value 
                            | 
                           
                               Min.: -4096.00 Nm, Max.: 4095.87 Nm 
                            | 
                        
                        
                           | 
                               Generator Torque 
                            | 
                           
                               Generator (MG1) torque execution value 
                            | 
                           
                               Min.: -4096.00 Nm, Max.: 4095.87 Nm 
                            | 
                        
                        
                           | 
                               Motor Revolution 
                            | 
                           
                               Motor (MG2) speed (detected by resolver sensor) 
                            | 
                           
                               Min.: -32768 rpm, Max.: 32767 rpm 
                            | 
                        
                        
                           | 
                               Target Motor Torque 
                            | 
                           
                               Motor (MG2) torque request value 
                            | 
                           
                               Min.: -4096.00 Nm, Max.: 4095.87 Nm 
                            | 
                        
                        
                           | 
                               Motor Torque 
                            | 
                           
                               Motor (MG2) torque execution value 
                            | 
                           
                               Min.: -4096.00 Nm, Max.: 4095.87 Nm 
                            | 
                        
                        
                           | 
                               Rear Motor Revolution 
                            | 
                           
                               Rear motor (MGR) speed (detected by resolver sensor) 
                            | 
                           
                               Min.: -32768 rpm, Max.: 32767 rpm 
                            | 
                        
                        
                           | 
                               Target Rear Motor Torque 
                            | 
                           
                               Rear motor (MGR) torque request value 
                            | 
                           
                               Min.: -4096.00 Nm, Max.: 4095.87 Nm 
                            | 
                        
                        
                           | 
                               Rear Motor Torque 
                            | 
                           
                               Rear motor (MGR) torque value 
                            | 
                           
                               Min.: -4096.000 Nm, Max.: 4095.875 Nm 
                            | 
                        
                        
                           | 
                               Rear Motor Torque Ratio 
                            | 
                           
                               Rear motor torque ratio 
                            | 
                           
                               - 
                            | 
                        
                        
                           | 
                               Request Motor Regenerative Brake Torque 
                            | 
                           
                               Requested motor (MG2) regenerative braking torque 
                            | 
                           
                               Min.: -4096.00 Nm, Max.: 4095.87 Nm 
                            | 
                        
                        
                           | 
                               Motor Regenerate Brake Execution Torque 
                            | 
                           
                               Motor (MG2) regenerative braking execution torque 
                            | 
                           
                               Min.: -4096.00 Nm, Max.: 4095.87 Nm 
                            | 
                        
                        
                           | 
                               Request Rear Motor Regenerative Brake Torque 
                            | 
                           
                               Requested rear motor (MGR) regenerative braking torque 
                            | 
                           
                               Min.: -4096.00 Nm, Max.: 4095.87 Nm 
                            | 
                        
                        
                           | 
                               Rear Motor Regenerate Brake Execution Torque 
                            | 
                           
                               Rear motor (MGR) regenerative braking execution torque 
                            | 
                           
                               Min.: -4096.00 Nm, Max.: 4095.87 Nm 
                            | 
                        
                        
                           | 
                               Generator Temperature 
                            | 
                           
                               Generator (MG1) temperature 
                            | 
                           
                               Min.: -40°C (-40°F), Max.: 215°C (419°F) 
                            | 
                        
                        
                           | 
                               Generator Temperature Sensor Voltage 
                            | 
                           
                               Generator (MG1) temperature sensor voltage 
                            | 
                           
                               Min.: 0.00 V, Max.: 4.99 V 
                            | 
                        
                        
                           | 
                               Generator Temperature just after IG ON 
                            | 
                           
                               Generator (MG1) temperature soon after ignition switch ON 
                            | 
                           
                               Min.: -40°C (-40°F), Max.: 215°C (419°F) 
                            | 
                        
                        
                           | 
                               Generator Maximum Temperature 
                            | 
                           
                               Maximum generator (MG1) temperature after ignition switch turned ON in current trip 
                            | 
                           
                               Min.: -40°C (-40°F), Max.: 215°C (419°F) 
                            | 
                        
                        
                           | 
                               Motor Temperature 
                            | 
                           
                               Motor (MG2) temperature 
                            | 
                           
                               Min.: -40°C (-40°F), Max.: 215°C (419°F) 
                            | 
                        
                        
                           | 
                               Motor Temperature Sensor Voltage 
                            | 
                           
                               Motor (MG2) temperature sensor voltage 
                            | 
                           
                               Min.: 0.00 V, Max.: 4.99 V 
                            | 
                        
                        
                           | 
                               Motor Temperature just after IG ON 
                            | 
                           
                               Motor (MG2) temperature soon after ignition switch ON 
                            | 
                           
                               Min.: -40°C (-40°F), Max.: 215°C (419°F) 
                            | 
                        
                        
                           | 
                               Motor Maximum Temperature 
                            | 
                           
                               Maximum motor (MG2) temperature after ignition switch turned ON in current trip 
                            | 
                           
                               Min.: -40°C (-40°F), Max.: 215°C (419°F) 
                            | 
                        
                        
                           | 
                               Rear Motor Temperature 
                            | 
                           
                               Rear motor (MGR) temperature 
                            | 
                           
                               Min.: -40°C (-40°F), Max.: 215°C (419°F) 
                            | 
                        
                        
                           | 
                               Rear Motor Temperature Sensor Voltage 
                            | 
                           
                               Rear motor (MGR) temperature sensor voltage 
                            | 
                           
                               Min.: 0.00 V, Max.: 4.99 V 
                            | 
                        
                        
                           | 
                               Rear Motor Temperature just after IG ON 
                            | 
                           
                               Rear motor (MGR) temperature soon after ignition switch ON 
                            | 
                           
                               Min.: -40°C (-40°F), Max.: 215°C (419°F) 
                            | 
                        
                        
                           | 
                               Rear Motor Maximum Temperature 
                            | 
                           
                               Maximum rear motor (MGR) temperature after ignition switch turned ON in current trip 
                            | 
                           
                               Min.: -40°C (-40°F), Max.: 215°C (419°F) 
                            | 
                        
                        
                           | 
                               Generator Inverter Temperature 
                            | 
                           
                               Generator inverter temperature 
                            | 
                           
                               Min.: 0°C (32°F), Max.: 150°C (302°F) 
                            | 
                        
                        
                           | 
                               Generator Inverter Temperature just after IG ON 
                            | 
                           
                               Generator inverter temperature soon after ignition switch ON 
                            | 
                           
                               Min.: 0°C (32°F), Max.: 150°C (302°F) 
                            | 
                        
                        
                           | 
                               Generator Inverter Maximum Temperature 
                            | 
                           
                               Maximum generator inverter temperature after ignition switch turned ON in current trip 
                            | 
                           
                               Min.: 0°C (32°F), Max.: 150°C (302°F) 
                            | 
                        
                        
                           | 
                               Motor Inverter Temperature 
                            | 
                           
                               Motor inverter temperature 
                            | 
                           
                               Min.: 0°C (32°F), Max.: 150°C (302°F) 
                            | 
                        
                        
                           | 
                               Motor Inverter Temperature just after IG ON 
                            | 
                           
                               Motor inverter temperature soon after ignition switch ON 
                            | 
                           
                               Min.: 0°C (32°F), Max.: 150°C (302°F) 
                            | 
                        
                        
                           | 
                               Motor Inverter Maximum Temperature 
                            | 
                           
                               Maximum motor inverter temperature after ignition switch turned ON in current trip 
                            | 
                           
                               Min.: 0°C (32°F), Max.: 150°C (302°F) 
                            | 
                        
                        
                           | 
                               Rear Motor Inverter Temperature 
                            | 
                           
                               Rear motor inverter temperature 
                            | 
                           
                               Min.: 0°C (32°F), Max.: 150°C (302°F) 
                            | 
                        
                        
                           | 
                               Rear Motor Inverter Temperature just after IG ON 
                            | 
                           
                               Rear motor inverter temperature soon after ignition switch ON 
                            | 
                           
                               Min.: 0°C (32°F), Max.: 150°C (302°F) 
                            | 
                        
                        
                           | 
                               Rear Motor Inverter Temperature before Operation 
                            | 
                           
                               Temperature of rear motor inverter before operation 
                            | 
                           
                               Min.: 0°C (32°F), Max.: 150°C (302°F) 
                            | 
                        
                        
                           | 
                               Rear Motor Inverter Maximum Temperature 
                            | 
                           
                               Maximum rear motor inverter temperature after ignition switch turned ON in current trip 
                            | 
                           
                               Min.: 0°C (32°F), Max.: 150°C (302°F) 
                            | 
                        
                        
                           | 
                               Boosting Converter Temperature (Upper) 
                            | 
                           
                               Boost converter temperature (upper) 
                            | 
                           
                               Min.: 0°C (32°F), Max.: 150°C (302°F) 
                            | 
                        
                        
                           | 
                               Boosting Converter Temperature (Lower) 
                            | 
                           
                               Boost converter temperature (lower) 
                            | 
                           
                               Min.: 0°C (32°F), Max.: 150°C (302°F) 
                            | 
                        
                        
                           | 
                               Boosting Converter Temperature just after IG ON 
                            | 
                           
                               Boost converter temperature soon after ignition switch ON 
                            | 
                           
                               Min.: 0°C (32°F), Max.: 150°C (302°F) 
                            | 
                        
                        
                           | 
                               Boosting Converter Maximum Temperature 
                            | 
                           
                               Maximum converter temperature after ignition switch turned ON in current trip 
                            | 
                           
                               Min.: 0°C (32°F), Max.: 150°C (302°F) 
                            | 
                        
                        
                           | 
                               Generator Inverter Operation Request 
                            | 
                           
                               Generator inverter operation request 
                            | 
                           
                               Shutdown / 3 Phase ON / Discharge / Insulation Resistance Measurement / Output Torque / Emergency Shutdown / Shutdown during Insulation Resistance Measurement 
                            | 
                        
                        
                           | 
                               Generator Inverter Fail 
                            | 
                           
                               Generator inverter stopped 
                            | 
                           
                               ON or OFF 
                            | 
                        
                        
                           | 
                               Generator Inverter Shutdown Status 
                            | 
                           
                               Generator inverter shutdown status 
                            | 
                           
                               Awake or Shutdown 
                            | 
                        
                        
                           | 
                               Motor Inverter Operation Request 
                            | 
                           
                               Motor inverter operation request 
                            | 
                           
                               Shutdown / 3 Phase ON / Discharge / Insulation Resistance Measurement / Output Torque / Emergency Shutdown / Shutdown during Insulation Resistance Measurement 
                            | 
                        
                        
                           | 
                               Motor Inverter Fail 
                            | 
                           
                               Motor inverter stopped 
                            | 
                           
                               ON or OFF 
                            | 
                        
                        
                           | 
                               Motor Inverter Shutdown Status 
                            | 
                           
                               Motor inverter shutdown status 
                            | 
                           
                               Awake or Shutdown 
                            | 
                        
                        
                           | 
                               Rear Motor Inverter Operation Request 
                            | 
                           
                               Rear motor inverter operation request 
                            | 
                           
                               Shutdown / 3 Phase ON / Discharge / Insulation Resistance Measurement / Output Torque / Emergency Shutdown / Shutdown during Insulation Resistance Measurement 
                            | 
                        
                        
                           | 
                               Rear Motor Inverter Fail 
                            | 
                           
                               Rear motor inverter stopped 
                            | 
                           
                               ON or OFF 
                            | 
                        
                        
                           | 
                               Rear Motor Inverter Shutdown Status 
                            | 
                           
                               Rear inverter shutdown status 
                            | 
                           
                               ON or OFF 
                            | 
                        
                        
                           | 
                               Boosting Converter Operation Request 
                            | 
                           
                               Boosting converter operation request 
                            | 
                           
                               Normal / Boosting Stop / Upper Arm ON / Maximum Boosting / Output Torque / Upper Arm Lowering 
                            | 
                        
                        
                           | 
                               Boosting Converter Fail 
                            | 
                           
                               Boost converter stopped 
                            | 
                           
                               ON or OFF 
                            | 
                        
                        
                           | 
                               Boosting Converter Shutdown Status 
                            | 
                           
                               Boost converter shutdown status 
                            | 
                           
                               Awake or Shutdown 
                            | 
                        
                        
                           | 
                               Generator Carrier Frequency 
                            | 
                           
                               Generator carrier frequency 
                            | 
                           
                               0.75 kHz / 1.25 kHz / 2.5 kHz / 3.75 kHz / 5 kHz / 10 kHz / Electrical Power Loss Reduction Mode 
                            | 
                        
                        
                           | 
                               Generator Control Mode 
                            | 
                           
                               Generator (MG1) control mode 
                            | 
                           
                               Sine Wave / Overmodulation / Square Wave / Electrical Power Loss Reduction Mode 
                            | 
                        
                        
                           | 
                               Motor Carrier Frequency 
                            | 
                           
                               Motor (MG2) carrier frequency 
                            | 
                           
                               0.75 kHz / 1.25 kHz / 2.5 kHz / 3.75 kHz / 5 kHz / 10 kHz / Electrical Power Loss Reduction Mode 
                            | 
                        
                        
                           | 
                               Motor Control Mode 
                            | 
                           
                               Motor (MG2) control mode 
                            | 
                           
                               Sine Wave / Overmodulation / Square Wave / Electrical Power Loss Reduction Mode 
                            | 
                        
                        
                           | 
                               Rear Motor Carrier Frequency 
                            | 
                           
                               Rear Motor carrier frequency 
                            | 
                           
                               0.75 kHz / 1.25 kHz / 2.5 kHz / 3.75 kHz / 5 kHz / 10 kHz / Electrical Power Loss Reduction Mode 
                            | 
                        
                        
                           | 
                               Rear Motor Control Mode 
                            | 
                           
                               Rear Motor control mode 
                            | 
                           
                               Sine Wave / Overmodulation / Square Wave / Electrical Power Loss Reduction Mode 
                            | 
                        
                        
                           | 
                               Boosting Converter Carrier Frequency 
                            | 
                           
                               Boost converter signal carrier frequency 
                            | 
                           
                               9.55 kHz / 9.13 kHz / 8.71 kHz / 8.29 kHz / 7.87 kHz / 7.45 kHz / 4.8 kHz 
                            | 
                        
                        
                           | 
                               VL-Voltage before Boosting 
                            | 
                           
                               High voltage before it is boosted 
                            | 
                           
                               - 
                            | 
                        
                        
                           | 
                               VL-Voltage before Boosting for Rear Motor 
                            | 
                           
                               Rear motor supply voltage before it is boosted 
                            | 
                           
                               - 
                            | 
                        
                        
                           | 
                               VH-Voltage after Boosting 
                            | 
                           
                               High voltage after it is boosted 
                            | 
                           
                               - 
                            | 
                        
                        
                           | 
                               Boost Ratio 
                            | 
                           
                               Boost converter boost ratio 
                            | 
                           
                               Min.: 0.0%, Max.: 100.0% 
                            | 
                        
                        
                           | 
                               V Phase Generator Current 
                            | 
                           
                               V phase generator current 
                            | 
                           
                               Min.: -3276.8 A, Max.: 3276.7 A 
                            | 
                        
                        
                           | 
                               W Phase Generator Current 
                            | 
                           
                               W phase generator current 
                            | 
                           
                               Min.: -3276.8 A, Max.: 3276.7 A 
                            | 
                        
                        
                           | 
                               V Phase Motor Current 
                            | 
                           
                               V phase motor current 
                            | 
                           
                               Min.: -3276.8 A, Max.: 3276.7 A 
                            | 
                        
                        
                           | 
                               W Phase Motor Current 
                            | 
                           
                               W phase motor current 
                            | 
                           
                               Min.: -3276.8 A, Max.: 3276.7 A 
                            | 
                        
                        
                           | 
                               V Phase Rear Motor Current 
                            | 
                           
                               V phase rear motor current 
                            | 
                           
                               Min.: -3276.8 A, Max.: 3276.7 A 
                            | 
                        
                        
                           | 
                               W Phase Rear Motor Current 
                            | 
                           
                               W phase rear motor current 
                            | 
                           
                               Min.: -3276.8 A, Max.: 3276.7 A 
                            | 
                        
                        
                           | 
                               Inverter Coolant Water Temperature 
                            | 
                           
                               Inverter coolant temperature 
                            | 
                           
                               Min.: -40°C (-40°F), Max.: 110°C (230°F) 
                            | 
                        
                        
                           | 
                               Inverter Water Pump Duty Ratio 
                            | 
                           
                               Inverter water pump motor driver request duty 
                            | 
                           
                               Min.: 0.0%, Max.: 100.0% 
                            | 
                        
                        
                           | 
                               Inverter Water Pump Revolution 
                            | 
                           
                               Inverter water pump assembly speed 
                            | 
                           
                               Min.: 0 rpm, Max.: 15000 rpm 
                            | 
                        
                        
                           | 
                               Overvoltage Input to Inverter 
                            | 
                           
                               Overvoltage detection into inverter 
                            | 
                           
                               ON or OFF 
                            | 
                        
                        
                           | 
                               Inverter Emergency Shutdown (Main CPU) 
                            | 
                           
                               Inverter emergency shutdown 
                            | 
                           
                               ON or OFF 
                            | 
                        
                        
                           | 
                               Inverter Emergency Shutdown (Sub CPU) 
                            | 
                           
                               Inverter emergency shutdown 
                            | 
                           
                               ON or OFF 
                            | 
                        
                        
                           | 
                               Inverter Input Current 
                            | 
                           
                               Inverter input current 
                            | 
                           
                               Min.: -3276.8 A, Max.: 3276.7 A 
                            | 
                        
                        
                           | 
                               Overvoltage Input to Boosting Converter 
                            | 
                           
                               Overvoltage detection into boost converter 
                            | 
                           
                               ON or OFF 
                            | 
                        
                        
                           | 
                               Motor/Generator Reactor Current before SMR Precharge 
                            | 
                           
                               Reactor current before system main relay precharge 
                            | 
                           
                               Min.: -3276.8 A, Max.: 3276.7 A 
                            | 
                        
                        
                           | 
                               Motor/Generator Reactor Maximum Current during SMR Precharge 
                            | 
                           
                               Highest reactor current during system main relay precharge 
                            | 
                           
                               Min.: -3276.8 A, Max.: 3276.7 A 
                            | 
                        
                        
                           | 
                               Motor/Generator Reactor Current-Carrying Status during SMR Precharge 
                            | 
                           
                               Current flowing through reactor during system main relay precharge 
                            | 
                           
                               Indefinite / Definite 
                            | 
                        
                        
                           | 
                               Motor/Generator Reactor Noncurrent-Carrying Status during SMR Precharge 
                            | 
                           
                               Current not flowing through reactor during system main relay precharge 
                            | 
                           
                               Indefinite / Definite 
                            | 
                        
                        
                           | 
                               Hybrid/EV Battery SOC 
                            | 
                           
                               HV battery state of charge 
                              Primary calculated from charging and discharging amperage 
                            | 
                           
                               Min.: 0.00%, Max.: 100.00% 
                            | 
                        
                        
                           | 
                               Hybrid/EV Battery SOC of Immediately after IG ON 
                            | 
                           
                               HV battery state of charge soon after ignition switch ON 
                            | 
                           
                               Min.: 0.0%, Max.: 100.0% 
                            | 
                        
                        
                           | 
                               Hybrid/EV Battery Maximum SOC 
                            | 
                           
                               Maximum SOC after ignition switch turned ON in current trip 
                            | 
                           
                               Min.: 0.0%, Max.: 100.0% 
                            | 
                        
                        
                           | 
                               Hybrid/EV Battery Minimum SOC 
                            | 
                           
                               Minimum SOC after ignition switch turned ON in current trip 
                            | 
                           
                               Min.: 0.0%, Max.: 100.0% 
                            | 
                        
                        
                           | 
                               Hybrid/EV Battery Voltage 
                            | 
                           
                               HV battery voltage 
                            | 
                           
                               Min.: 0.00 V, Max.: 1023.98 V 
                            | 
                        
                        
                           | 
                               Hybrid/EV Battery Current 
                            | 
                           
                               HV battery current 
                            | 
                           
                               Min.: -3276.8 A, Max.: 3276.7 A 
                            | 
                        
                        
                           | 
                               Hybrid/EV Battery Current for Driving Control 
                            | 
                           
                               Hybrid battery current for driving control 
                            | 
                           
                               Min.: -327.68 A, Max.: 327.67 A 
                            | 
                        
                        
                           | 
                               Hybrid/EV Battery Cooling Fan Low Speed Request 
                            | 
                           
                               Battery cooling blower assembly Lo speed requested 
                            | 
                           
                               ON or OFF 
                            | 
                        
                        
                           | 
                               Short Wave Highest Value Level 
                            | 
                           
                               Waveform voltage level in abnormal insulation detection circuit in battery voltage sensor 
                            | 
                           
                               Not Judge / Normal / Insulation Lower LV2 / Insulation Lower LV3 
                            | 
                        
                        
                           | 
                               Insulation Resistance Division Check Completion using Rear Motor Inv 
                            | 
                           
                               Insulation resistance division check completion using rear motor inverter 
                            | 
                           
                               Not Complete / Complete 
                            | 
                        
                        
                           | 
                               Insulation Resistance Division Check Completion using MG Inv 
                            | 
                           
                               Insulation resistance division check completion using MG inverter 
                            | 
                           
                               Not Complete / Complete 
                            | 
                        
                        
                           | 
                               Insulation Resistance Division Check Completion using A/C Inv 
                            | 
                           
                               Insulation resistance division check completion using A/C inverter 
                            | 
                           
                               Not Complete / Complete 
                            | 
                        
                        
                           | 
                               Insulation Resistance Division Check Completion using SMR 
                            | 
                           
                               Insulation resistance division check completion using SMR 
                            | 
                           
                               Not Complete / Complete 
                            | 
                        
                        
                           | 
                               Short Wave Highest Value Availability just after Rear Motor Inv On/Off 
                            | 
                           
                               Short wave highest value availability just after rear motor inverter on/off 
                            | 
                           
                               No or Yes 
                            | 
                        
                        
                           | 
                               Short Wave Highest Value Availability just after MG Inv On/Off 
                            | 
                           
                               Short wave highest value availability just after MG inverter on/off 
                            | 
                           
                               No or Yes 
                            | 
                        
                        
                           | 
                               Short Wave Highest Value Availability just after A/C Inv On/Off 
                            | 
                           
                               Short wave highest value availability just after A/C inverter on/off 
                            | 
                           
                               No or Yes 
                            | 
                        
                        
                           | 
                               Short Wave Highest Value Availability just after SMR On/Off 
                            | 
                           
                               Short wave highest value availability just after SMR on/off 
                            | 
                           
                               No or Yes 
                            | 
                        
                        
                           | 
                               Immobiliser Communication 
                            | 
                           
                               Immobiliser communication line status 
                            | 
                           
                               ON or OFF 
                            | 
                        
                        
                           | 
                               Permit Start by Immobiliser 
                            | 
                           
                               Status of starting permission by immobiliser (immobiliser to hybrid vehicle control ECU assembly) 
                            | 
                           
                               No Judgment / OK / NG 
                            | 
                        
                        
                           | 
                               Auxiliary Battery Voltage 
                            | 
                           
                               Auxiliary battery voltage 
                            | 
                           
                               Min.: 0.00 V, Max.: 16.00 V 
                            | 
                        
                        
                           | 
                               Auxiliary Battery Voltage just before SMR Precharge 
                            | 
                           
                               Auxiliary battery voltage just before SMR precharge 
                            | 
                           
                               Min.: 0.00 V, Max.: 79.99 V 
                            | 
                        
                        
                           | 
                               Auxiliary Battery Current 
                            | 
                           
                               Auxiliary battery current 
                            | 
                           
                               Min.: -125.00 A, Max.: 124.99 A 
                            | 
                        
                        
                           | 
                               Smoothed Value of Auxiliary Battery Temperature 
                            | 
                           
                               Smoothed value of auxiliary battery temperature 
                            | 
                           
                               Min.: -30.0°C (-22.0°F), Max.: 6513.5°C (11756.3°F) 
                            | 
                        
                        
                           | 
                               Auxiliary Battery Status of Full Charge 
                            | 
                           
                               Auxiliary battery status when full charge 
                            | 
                           
                               Min.: 0.0 Ah, Max.: 127.5 Ah 
                            | 
                        
                        
                           | 
                               Auxiliary Battery Charging Rate Accuracy 
                            | 
                           
                               Auxiliary battery charging rate accuracy 
                            | 
                           
                               Low / Middle / High / Disable 
                            | 
                        
                        
                           | 
                               Auxiliary Battery Dark Current 
                            | 
                           
                               Auxiliary battery dark current 
                            | 
                           
                               Min.: 0 mA, Max.: 65535 mA 
                            | 
                        
                        
                           | 
                               Auxiliary Battery Sensor Sleep Time 
                            | 
                           
                               Auxiliary battery sensor sleep time 
                            | 
                           
                               Min.: 0 h, Max.: 255 h 
                            | 
                        
                        
                           | 
                               Power Feeding Electrical Using Status 
                            | 
                           
                               Usage state of power supplied from external power source charging 
                            | 
                           
                               Charge Sustaining Mode/Not PHV / Charge Depleting Mode / Charge Increasing Mode / Ready OFF 
                            |