                               Room Temperature Sensor 
                            | 
                           
                               Cooler thermistor (room temperature sensor) 
                            | 
                           
                               Min.: -6.50°C (20.30°F) 
                              Max.: 57.25°C (135.05°F) 
                            | 
                           
                               Actual cabin temperature displayed 
                            | 
                           
                               Cooler thermistor (room temperature sensor) circuit malfunction 
                              
                                 
                                    - 
When open circuit: -6.50°C (20.30°F)
 
                                    - 
When short circuit: 57.25°C (135.05°F)
 
                                  
                               
                            | 
                        
                        
                           | 
                               Ambient Temp Sensor 
                            | 
                           
                               Thermistor assembly 
                            | 
                           
                               Min.: -23.30°C (-9.94°F) 
                              Max.: 65.95°C (150.71°F) 
                            | 
                           
                               Actual ambient temperature displayed 
                            | 
                           
                               Thermistor assembly circuit malfunction 
                              
                                 
                                    - 
When open circuit: -23.30°C (-9.94°F)
 
                                    - 
When short circuit: 65.95°C (150.71°F)
 
                                  
                               
                            | 
                        
                        
                           | 
                               Adjusted Ambient Temp 
                            | 
                           
                               Adjusted ambient temperature 
                            | 
                           
                               Min.: -30.80°C (-23.44°F) 
                              Max.: 50.80°C (123.44°F) 
                            | 
                           
                               Adjust ambient temperature displayed 
                            | 
                           
                               Air conditioning amplifier assembly circuit malfunction 
                            | 
                        
                        
                           | 
                               Evaporator Fin Thermistor 
                            | 
                           
                               No. 1 cooler thermistor 
                            | 
                           
                               Min.: -29.70°C (-21.46°F) 
                              Max.: 59.55°C (139.19°F) 
                            | 
                           
                               Actual evaporator temperature displayed 
                            | 
                           
                               No. 1 cooler thermistor circuit malfunction 
                              
                                 
                                    - 
When open circuit: -29.70°C (-21.46°F)
 
                                    - 
When short circuit: 59.55°C (139.19°F)
 
                                  
                               
                            | 
                        
                        
                           | 
                               Evaporator Target Temp 
                            | 
                           
                               Evaporator target temperature 
                            | 
                           
                               Min.: -327.68°C (-557.82°F) 
                              Max.: 327.67°C (621.81°F) 
                            | 
                           
                               Evaporator target temperature displayed 
                            | 
                           
                               No. 1 cooler thermistor circuit malfunction 
                              
                                 
                                    - 
When open circuit: -327.68°C (-557.82°F)
 
                                    - 
When short circuit: 327.67°C (621.81°F)
 
                                  
                               
                            | 
                        
                        
                           | 
                               Solar Sensor (D Side) 
                            | 
                           
                               Driver side automatic light control sensor 
                            | 
                           
                               Min.: 0 
                              Max.: 255 
                            | 
                           
                               Driver side automatic light control sensor value increases as brightness increases 
                            | 
                           
                               Driver side automatic light control sensor circuit malfunction 
                              
                                 
                                    - 
When open circuit: 0
 
                                    - 
When short circuit: 255
 
                                  
                               
                            | 
                        
                        
                           | 
                               Solar Sensor (P Side) 
                            | 
                           
                               Front passenger side automatic light control sensor 
                            | 
                           
                               Min.: 0 
                              Max.: 255 
                            | 
                           
                               Front passenger side automatic light control sensor value increases as brightness increases 
                            | 
                           
                               Front passenger side automatic light control sensor circuit malfunction 
                              
                                 
                                    - 
When open circuit: 0
 
                                    - 
When short circuit: 255
 
                                  
                               
                            | 
                        
                        
                           | 
                               Engine Coolant Temp 
                            | 
                           
                               Engine coolant temperature sensor 
                            | 
                           
                               Min.: 1.30°C (34.34°F) 
                              Max.: 90.55°C (194.99°F) 
                            | 
                           
                               Actual engine coolant temperature displayed 
                            | 
                           
                              
                                 
                                    - 
SFI system malfunction
 
                                    - 
CAN communication system malfunction
 
                                  
                               
                            | 
                        
                        
                           | 
                               Blower Motor Speed Level 
                            | 
                           
                               Blower motor speed level 
                            | 
                           
                               Min.: 0 
                              Max.: 31 
                            | 
                           
                               Displayed speed level increases in range between 0 and 31 as blower motor speed increases 
                            | 
                           
                               Blower with fan motor sub-assembly circuit malfunction 
                            | 
                        
                        
                           | 
                               Regulator Pressure Sensor 
                            | 
                           
                               Air conditioner pressure sensor 
                            | 
                           
                               Min.: -456.6 kPaG (gauge) 
                              Max.: 3294.3 kPaG (gauge) 
                            | 
                           
                               Actual refrigerant pressure displayed 
                            | 
                           
                              
                                 
                                    - 
Refrigerant line (gas leak etc.)
 
                                    - 
Air conditioner pressure sensor circuit malfunction
 
                                  
                               
                            | 
                        
                        
                           | 
                               Air Outlet Servo Pulse (R) 
                            | 
                           
                               No. 2 air conditioning radiator damper servo sub-assembly target pulse 
                            | 
                           
                               Min.: 128 
                              Max.: 383 
                            | 
                           
                              
                                 
                                    - 
FACE: 260 (pulse)
 
                                    - 
FOOT-R, D, O, F/D: 223 (pulse)
 
                                    - 
B/L: 212 (pulse)
 
                                    - 
FOOT-F: 182 (pulse)
 
                                    - 
D/F: 177 (pulse)
 
                                    - 
DEF: 158 (pulse)
 
                                  
                               
                            | 
                           
                               No. 2 air conditioning radiator damper servo sub-assembly circuit malfunction 
                            | 
                        
                        
                           | 
                               Air Outlet Servo Actual Pls(R) 
                            | 
                           
                               No. 2 air conditioning radiator damper servo sub-assembly actual pulse 
                            | 
                           
                               Min.: 128 
                              Max.: 383 
                            | 
                           
                              
                                 
                                    - 
FACE: 260 (pulse)
 
                                    - 
FOOT-R, D, O, F/D: 223 (pulse)
 
                                    - 
B/L: 212 (pulse)
 
                                    - 
FOOT-F: 182 (pulse)
 
                                    - 
D/F: 177 (pulse)
 
                                    - 
DEF: 158 (pulse)
 
                                  
                               
                            | 
                           
                               No. 2 air conditioning radiator damper servo sub-assembly circuit malfunction 
                            | 
                        
                        
                           | 
                               Air Mix Servo Targ Pulse(D) 
                            | 
                           
                               No. 1 air conditioning radiator damper servo sub-assembly (driver side air mix) target pulse 
                            | 
                           
                               Min.: 128 
                              Max.: 383 
                            | 
                           
                              
                                 
                                    - 
MAX COLD: 257 (pulse)
 
                                    - 
MAX HOT: 165 (pulse)
 
                                  
                               
                            | 
                           
                               No. 1 air conditioning radiator damper servo sub-assembly (driver side air mix) circuit malfunction 
                            | 
                        
                        
                           | 
                               Air Mix Servo Actual Pulse(D) 
                            | 
                           
                               No. 1 air conditioning radiator damper servo sub-assembly (driver side air mix) actual pulse 
                            | 
                           
                               Min.: 128 
                              Max.: 383 
                            | 
                           
                              
                                 
                                    - 
MAX COLD: 257 (pulse)
 
                                    - 
MAX HOT: 165 (pulse)
 
                                  
                               
                            | 
                           
                               No. 1 air conditioning radiator damper servo sub-assembly (driver side air mix) circuit malfunction 
                            | 
                        
                        
                           | 
                               Air Mix Servo Targ Pulse(P) 
                            | 
                           
                               No. 1 air conditioning radiator damper servo sub-assembly (front passenger side air mix) target pulse 
                            | 
                           
                               Min.: 128 
                              Max.: 383 
                            | 
                           
                              
                                 
                                    - 
MAX COLD: 255 (pulse)
 
                                    - 
MAX HOT: 347 (pulse)
 
                                  
                               
                            | 
                           
                               No. 1 air conditioning radiator damper servo sub-assembly (front passenger side air mix) circuit malfunction 
                            | 
                        
                        
                           | 
                               Air Mix Servo Actual Pulse(P) 
                            | 
                           
                               No. 1 air conditioning radiator damper servo sub-assembly (front passenger side air mix) actual pulse 
                            | 
                           
                               Min.: 128 
                              Max.: 383 
                            | 
                           
                              
                                 
                                    - 
MAX COLD: 255 (pulse)
 
                                    - 
MAX HOT: 347 (pulse)
 
                                  
                               
                            | 
                           
                               No. 1 air conditioning radiator damper servo sub-assembly (front passenger side air mix) circuit malfunction 
                            | 
                        
                        
                           | 
                               Air Outlet Servo Pulse (D) 
                            | 
                           
                               No. 3 air conditioning radiator damper servo sub-assembly (driver side mode) target pulse 
                            | 
                           
                               Min.: 128 
                              Max.: 383 
                            | 
                           
                              
                                 
                                    - 
S-FLOW: 278 (pulse)
 
                                    - 
FACE: 256 (pulse)
 
                                    - 
B/L: 245 (pulse)
 
                                    - 
FOOT-A: 224 (pulse)
 
                                    - 
FOOT-R (F): 215 (pulse)
 
                                    - 
FOOT-D: 207 (pulse)
 
                                    - 
F/D-R: 192 (pulse)
 
                                    - 
D/F: 173 (pulse)
 
                                    - 
DEF: 164 (pulse)
 
                                  
                               
                            | 
                           
                               No. 3 air conditioning radiator damper servo sub-assembly (driver side mode) circuit malfunction 
                            | 
                        
                        
                           | 
                               Air Outlet Servo Actu Pulse(D) 
                            | 
                           
                               No. 3 air conditioning radiator damper servo sub-assembly (driver side mode) actual pulse 
                            | 
                           
                               Min.: 128 
                              Max.: 383 
                            | 
                           
                              
                                 
                                    - 
S-FLOW: 278 (pulse)
 
                                    - 
FACE: 256 (pulse)
 
                                    - 
B/L: 245 (pulse)
 
                                    - 
FOOT-A: 224 (pulse)
 
                                    - 
FOOT-R (F): 215 (pulse)
 
                                    - 
FOOT-D: 207 (pulse)
 
                                    - 
F/D-R: 192 (pulse)
 
                                    - 
D/F: 173 (pulse)
 
                                    - 
DEF: 164 (pulse)
 
                                  
                               
                            | 
                           
                               No. 3 air conditioning radiator damper servo sub-assembly (driver side mode) circuit malfunction 
                            | 
                        
                        
                           | 
                               Air Outlet Servo Targ Pulse(P) 
                            | 
                           
                               No. 1 air conditioning radiator damper servo sub-assembly (front passenger side mode) target pulse 
                            | 
                           
                               Min.: 128 
                              Max.: 383 
                            | 
                           
                              
                                 
                                    - 
S-FLOW: 234 (pulse)
 
                                    - 
FACE: 256 (pulse)
 
                                    - 
B/L: 267 (pulse)
 
                                    - 
FOOT-A: 288 (pulse)
 
                                    - 
FOOT-R (F): 297 (pulse)
 
                                    - 
FOOT-D: 305 (pulse)
 
                                    - 
F/D-R: 320 (pulse)
 
                                    - 
D/F: 339 (pulse)
 
                                    - 
DEF: 348 (pulse)
 
                                  
                               
                            | 
                           
                               No. 3 air conditioning radiator damper servo sub-assembly (front passenger side mode) circuit malfunction 
                            | 
                        
                        
                           | 
                               Air Outlet Servo Actu Pulse(P) 
                            | 
                           
                               No. 1 air conditioning radiator damper servo sub-assembly (front passenger side mode) actual pulse 
                            | 
                           
                               Min.: 128 
                              Max.: 383 
                            | 
                           
                              
                                 
                                    - 
S-FLOW: 234 (pulse)
 
                                    - 
FACE: 256 (pulse)
 
                                    - 
B/L: 267 (pulse)
 
                                    - 
FOOT-A: 288 (pulse)
 
                                    - 
FOOT-R (F): 297 (pulse)
 
                                    - 
FOOT-D: 305 (pulse)
 
                                    - 
F/D-R: 320 (pulse)
 
                                    - 
D/F: 339 (pulse)
 
                                    - 
DEF: 348 (pulse)
 
                                  
                               
                            | 
                           
                               No. 3 air conditioning radiator damper servo sub-assembly (front passenger side mode) circuit malfunction 
                            | 
                        
                        
                           | 
                               Air Inlet Damper Targ Pulse 
                            | 
                           
                               No. 1 blower damper servo sub-assembly target pulse 
                            | 
                           
                               Min.: 128 
                              Max.: 383 
                            | 
                           
                              
                                 
                                    - 
Recirculation: 256 (pulse)
 
                                    - 
Fresh: 220 (pulse)
 
                                  
                               
                            | 
                           
                               No. 1 blower damper servo sub-assembly circuit malfunction 
                            | 
                        
                        
                           | 
                               Air Inlet Damper Actual Pulse 
                            | 
                           
                               No. 1 blower damper servo sub-assembly actual pulse 
                            | 
                           
                               Min.: 128 
                              Max.: 383 
                            | 
                           
                              
                                 
                                    - 
Recirculation: 256 (pulse)
 
                                    - 
Fresh: 220 (pulse)
 
                                  
                               
                            | 
                           
                               No. 1 blower damper servo sub-assembly circuit malfunction 
                            | 
                        
                        
                           | 
                               Compressor Speed 
                            | 
                           
                               Compressor speed 
                            | 
                           
                               Min.: 0 rpm 
                              Max.: 65535 rpm 
                            | 
                           
                               Actual compressor speed displayed 
                            | 
                           
                               - 
                            | 
                        
                        
                           | 
                               Compressor Target Speed 
                            | 
                           
                               Compressor target speed 
                            | 
                           
                               Min.: 0 rpm 
                              Max.: 65535 rpm 
                            | 
                           
                               Compressor target speed displayed 
                            | 
                           
                               - 
                            | 
                        
                        
                           | 
                               Shift Set Temperature 
                            | 
                           
                               Shift set temperature 
                            | 
                           
                               2C decr, 1C decr, Normal, 1C incr or 2C incr 
                            | 
                           
                               Customized value displayed 
                            | 
                           
                               - 
                            | 
                        
                        
                           | 
                               Air Inlet Mode 
                            | 
                           
                               Air inlet mode 
                            | 
                           
                               Auto or Manual 
                            | 
                           
                               Customized value displayed 
                            | 
                           
                               - 
                            | 
                        
                        
                           | 
                               Compressor Mode 
                            | 
                           
                               Compressor mode 
                            | 
                           
                               Auto or Manual 
                            | 
                           
                               Customized value displayed 
                            | 
                           
                               - 
                            | 
                        
                        
                           | 
                               Noise and Vibration Reduction 
                            | 
                           
                               Function to change the speed of the compressor when set to ON 
                            | 
                           
                               OFF or ON 
                            | 
                           
                               Customized value displayed 
                            | 
                           
                               - 
                            | 
                        
                        
                           | 
                               ECO MODE Cancel 
                            | 
                           
                               Function to cancel ECO mode when set to ON 
                            | 
                           
                               OFF or ON 
                            | 
                           
                               Customized value displayed 
                            | 
                           
                               - 
                            | 
                        
                        
                           | 
                               ECO Switch 
                            | 
                           
                               Integration control and panel assembly (ECO switch) 
                            | 
                           
                               OFF or ON 
                            | 
                           
                               OFF: Integration control and panel assembly (ECO switch) not pushed 
                              ON: Integration control and panel assembly (ECO switch) pushed and held 
                            | 
                           
                               Integration control and panel assembly (ECO switch) circuit malfunction 
                            | 
                        
                        
                           | 
                               Refrigerant Shortage Check 
                            | 
                           
                               Refrigerant shortage check 
                            | 
                           
                               ON or OFF 
                            | 
                           
                               Customized value displayed 
                            | 
                           
                               - 
                            | 
                        
                        
                           | 
                               Fan speed increment control 
                            | 
                           
                               Fan speed increment control 
                            | 
                           
                               Slow, Normal or Fast 
                            | 
                           
                               Customized value displayed 
                            | 
                           
                               - 
                            | 
                        
                        
                           | 
                               Foot/DEF Auto Mode 
                            | 
                           
                               Foot/defroster auto mode 
                            | 
                           
                               ON or OFF 
                            | 
                           
                               Customized value displayed 
                            | 
                           
                               - 
                            | 
                        
                        
                           | 
                               Foot/DEF Auto Blow Up 
                            | 
                           
                               Foot/defroster auto blower speed increase 
                            | 
                           
                               ON or OFF 
                            | 
                           
                               Customized value displayed 
                            | 
                           
                               - 
                            | 
                        
                        
                           | 
                               Ambient Temperature Shift 
                            | 
                           
                               Ambient temperature shift 
                            | 
                           
                               3C decr, 2C decr, 1C decr, Normal, 1C incr, 2C incr or 3C incr 
                            | 
                           
                               Customized value displayed 
                            | 
                           
                               - 
                            | 
                        
                        
                           | 
                               Compressor Drive Check 
                            | 
                           
                               Compressor drive check 
                            | 
                           
                               OK or NG 
                            | 
                           
                               OK: Compressor drives 
                              NG: Compressor does not drive 
                            | 
                           
                               - 
                            | 
                        
                        
                           | 
                               Refrigerant Gas Type 
                            | 
                           
                               Refrigerant gas type 
                            | 
                           
                               R134a or 1234yf 
                            | 
                           
                               Refrigerant gas type displayed 
                            | 
                           
                               - 
                            | 
                        
                        
                           | 
                               Set Temperature (D Side) 
                            | 
                           
                               Driver side set temperature 
                            | 
                           
                               Min.: MAX COLD 
                              Max.: MAX HOT 
                            | 
                           
                               Driver side set temperature displayed 
                            | 
                           
                               - 
                            | 
                        
                        
                           | 
                               Set Temperature (P Side) 
                            | 
                           
                               Front passenger side set temperature 
                            | 
                           
                               Min.: MAX COLD 
                              Max.: MAX HOT 
                            | 
                           
                               Front passenger side set temperature displayed 
                            | 
                           
                               - 
                            | 
                        
                        
                           | 
                               Operation Limitation Control History Count (Level1) 
                            | 
                           
                               History of auxiliary battery voltage drop in the past 
                            | 
                           
                               Min.: 0 
                              Max.: 255 
                            | 
                           
                               Number of times auxiliary battery voltage dropped in the past displayed 
                            | 
                           
                              
                                 
                                    - 
Counted when voltage drops below the specified level due to over discharge while driving.
 
                                    - 
Refer to the following procedure to clear the A/C operation limitation history.
 
                                  
                               
                            | 
                        
                        
                           | 
                               Operation Limitation Control History Count (Level2) 
                            | 
                           
                               History of auxiliary battery voltage drop in the past 
                            | 
                           
                               Min.: 0 
                              Max.: 255 
                            | 
                           
                               Number of times auxiliary battery voltage dropped in the past displayed 
                            | 
                           
                              
                                 
                                    - 
Counted when voltage drops below the specified level due to over discharge while driving.
 
                                    - 
Refer to the following procedure to clear the A/C operation limitation history.
 
                                  
                               
                            | 
                        
                        
                           | 
                               Outside Air Mode Auto Switch Function 
                            | 
                           
                               Outside air mode auto switch function 
                            | 
                           
                               ON or OFF 
                            | 
                           
                               Customized value displayed 
                            | 
                           
                               - 
                            | 
                        
                        
                           | 
                               S-FLOW Control Auto Function 
                            | 
                           
                               S-FLOW control auto function 
                            | 
                           
                               ON or OFF 
                            | 
                           
                               Customized value displayed 
                            | 
                           
                               - 
                            | 
                        
                        
                           | 
                               Number of Trouble Codes 
                            | 
                           
                               Number of trouble codes 
                            | 
                           
                               Min.: 0 
                              Max.: 255 
                            | 
                           
                               Number of DTCs displayed 
                            | 
                           
                               - 
                            | 
                        
                        
                           | 
                               Refrigerant High Pressure History 
                            | 
                           
                               Refrigerant high pressure history 
                            | 
                           
                               Min.: 0 
                              Max.: 255 
                            | 
                           
                               Number of times refrigerant high pressure history stored displayed 
                            | 
                           
                               * 
                            |