Vehicle Speed
|
Vehicle speed
|
Min.: 0 km/h (0 mph), Max.: 255 km/h (158 mph)
|
Vehicle stopped:
0 km/h (0 mph)
While driving at a constant speed:
No significant fluctuation
|
-
|
Target Engine Power
|
Target engine power
|
Min.: 0 W, Max.: 655350 W
|
While driving with the engine running:
Varies depending on vehicle operating conditions
|
Requested engine power by hybrid vehicle control ECU assembly to ECM
-
Hybrid vehicle control ECU assembly
-
Motor generator control ECU
-
ECM
-
Engine
|
Execute Engine Power
|
Execute engine power
|
Min.: 0 W, Max.: 655350 W
|
While driving with the engine running:
Varies depending on vehicle operating conditions
|
-
|
Target Engine Revolution
|
Target engine speed
|
-
|
While driving with the engine running:
Varies depending on vehicle operating conditions
|
Target engine speed requested by hybrid vehicle control ECU assembly to ECM
-
Hybrid vehicle control ECU assembly
-
ECM
-
Engine
|
Engine Speed
|
Engine speed
|
-
|
Engine stopped:
0 rpm
While engine running at a constant speed:
No significant fluctuation
|
-
|
Calculate Load
|
Calculate load
|
Min.: 0.00%, Max.: 100.00%
|
-
|
Value increases in proportion to increase in load
-
Throttle valve status
-
Air cleaner condition
|
Coolant Temperature
|
Engine coolant temperature
|
Min.: -40°C (-40°F), Max.: 215°C (419°F)
|
Cold start→Fully warmed up:
Gradually rises
After warming up:
75 to 100°C (167 to 212°F)
|
-
|
Starter Switch Signal
|
Starter ON / OFF signal
|
ON or OFF
|
Starter ON:
ON
|
-
|
Engine Idling Request
|
Engine idling request
|
ON or OFF
|
Requesting idle:
ON
|
-
ECM
-
Hybrid vehicle control ECU assembly
|
Engine Start Request (A/C)
|
Engine idling request from air conditioning amplifier assembly
|
ON or OFF
|
While an engine start is requested from the air conditioning amplifier assembly:
ON
|
Air conditioning amplifier assembly
|
Engine Start Request (Engine Warm-up)
|
Engine idling request to warm up engine
|
ON or OFF
|
While an engine warm-up is requested:
ON
After the engine is warmed up:
OFF
|
-
Hybrid vehicle control ECU assembly
-
ECM
|
Engine Start Request (Hybrid/EV Battery Charging)
|
Engine idling request to charge HV battery
|
ON or OFF
|
Requesting HV battery charging:
ON
|
-
Battery ECU assembly
-
HV battery
|
Engine Mode
|
Engine status
|
Stop / Stop Process / Startup Process / Running
|
Engine stopped:
Stop
Engine stopping:
Stop Process
While the engine starting:
Startup Process
Engine running:
Running
|
-
Hybrid vehicle control ECU assembly
-
ECM
-
Hybrid vehicle transaxle assembly
|
Engine Run Time
|
Elapsed time after starting engine
|
Min.: 0 sec, Max.: 65535 sec
|
Elapsed time after starting engine
|
Elapsed time from initial engine start until the ignition switch is turned off.
|
Engine Stop Request
|
Engine stop request
|
ON or OFF
|
Requesting engine stop:
ON
|
-
ECM
-
Hybrid vehicle control ECU assembly
|
Engine Stop F/C Status
|
Engine fuel cut status
|
ON or OFF
|
While engine fuel cut:
ON
|
-
ECM
-
Hybrid vehicle control ECU assembly
|
Lack of Fuel
|
Lack of fuel
|
ON or OFF
|
Fuel level low:
ON
|
-
|
Accelerator Position
|
Accelerator pedal depressed angle
|
Min.: 0.0%, Max.: 100.0%
|
Accelerator pedal fully depressed:
100%
Accelerator pedal released:
0%
|
Accelerator pedal sensor assembly
|
Accelerator Pedal Status
|
Accelerator pedal status
|
ON or OFF
|
Accelerator pedal depressed:
ON
Accelerator pedal released:
OFF
|
Accelerator pedal sensor assembly
|
Accelerator Position Sensor No.1 Voltage %
|
Accelerator pedal position sensor No. 1
|
Min.: 0.00%, Max.: 100.00%
|
Accelerator pedal depressed:
Changes with accelerator pedal position
|
Sensor voltage is multiplied by 20 and displayed as a percentage
-
Accelerator pedal sensor assembly
|
Accelerator Position Sensor No.2 Voltage %
|
Accelerator pedal position sensor No. 2
|
Min.: 0.00%, Max.: 100.00%
|
Accelerator pedal depressed:
Changes with accelerator pedal position
|
Sensor voltage is multiplied by 20 and displayed as a percentage
-
Accelerator pedal sensor assembly
|
Throttle Position Sensor No.1 Voltage %
|
Throttle position sensor
|
Min.: 0.00%, Max.: 100.00%
|
-
|
Throttle valve status
|
Master Cylinder Control Torque
|
Braking torque equivalent to master cylinder brake fluid pressure
(Total braking torque)
|
-
|
Brake pedal depressed:
Changes with the brake pedal pressure
|
Master cylinder brake fluid pressure control torque = hydraulic brake control torque + regenerative brake torque
-
Master cylinder pressure sensor
|
Brake Cancel Switch
|
Brake cancel switch
|
ON or OFF
|
Brake pedal depressed:
OFF
Brake pedal released:
ON
|
-
|
Shift Position
|
Current shift state
|
P / R / N / D / B
|
Matches currently selected shift state:
P, R, N, D
|
-
|
Shift Position (Meter)
|
Shift position of meter display
|
Not Displayed / P / R / N / D / B
|
Matches currently selected shift state:
P, R, N, D
|
-
|
Shift Switch Status (N,P Position)
|
Shift position status (N or P position)
|
ON or OFF
|
Shift lever in P, N:
ON
|
-
|
Shift Position Sensor (PNB)
|
Shift position sensor
|
ON or OFF
|
Shift lever in P, N:
ON
Shift lever in any position other than P or N:
OFF
|
Shift lever position sensor
|
Shift Position Sensor (PR)
|
Shift position sensor
|
ON or OFF
|
Shift lever in P or R:
ON
Shift lever in any position other than P or R:
OFF
|
Shift lever position sensor
|
Shift Position Sensor (DB1)
|
Shift position sensor
|
ON or OFF
|
Shift lever in D or S:
ON
Shift lever in any position other than D or S:
OFF
|
Shift lever position sensor
|
Shift Position Sensor (DB2)
|
Shift position sensor
|
ON or OFF
|
Shift lever in D or S:
ON
Shift lever in any position other than D or S:
OFF
|
Shift lever position sensor
|
Shift Position Sensor (N)
|
Shift position sensor
|
ON or OFF
|
Shift lever in N:
ON
Shift lever in any position other than N:
OFF
|
Shift lever position sensor
|
Shift Position Sensor (R)
|
Shift position sensor
|
ON or OFF
|
Shift lever in R:
ON
Shift lever in any position other than R:
OFF
|
Shift lever position sensor
|
Shift Position Sensor (P)
|
Shift position sensor
|
ON or OFF
|
Shift lever in P:
ON
Shift lever in any position other than P:
OFF
|
Shift lever position sensor
|
Shift Lock Release Request
|
Shift lock release request
|
ON or OFF
|
ON:
Brake pedal depressed
OFF:
Other than above
|
-
|
Sports Shift Position
|
Sports shift position
|
Min.: 0, Max.: 255
|
Shift lever in S (1): 0
Shift lever in S (2): 1
Shift lever in S (3): 2
Shift lever in S (4): 3
Shift lever in S (5): 4
Shift lever in S (6): 5
Shift lever in any position other than S: 255
|
-
Hybrid vehicle control ECU assembly
-
Transmission control switch circuit
|
Sports Shift UP Signal
|
Sports shift UP signal
|
ON or OFF
|
Shift lever in "+":
ON
Shift lever in neutral:
OFF
|
-
Hybrid vehicle control ECU assembly
-
Transmission control switch circuit
|
Sports Shift DOWN Signal
|
Sports shift DOWN signal
|
ON or OFF
|
Shift lever in "-":
ON
Shift lever in neutral:
OFF
|
-
Hybrid vehicle control ECU assembly
-
Transmission control switch circuit
|
Transaxle Oil Temperature
|
Hybrid vehicle transaxle oil temperature
|
Min.: -40°C (-40°F), Max.: 215°C (419°F)
|
Vehicle left for 1 day at an ambient temperature of 25°C (77°F):
15 to 35°C (59 to 95°F)
While driving:
Varies depending on vehicle operating conditions
|
-
|
Transaxle Oil Temperature Sensor Voltage
|
Hybrid vehicle transaxle oil temperature sensor voltage
|
Min: 0.00 V, Max: 4.99 V
|
-
|
-
|
FR Wheel Speed
|
Front wheel speed RH
|
Min.: 0 km/h (0 mph), Max.: 327.67 km/h (204 mph)
|
Vehicle stopped:
0 km/h (0 mph)
Vehicle being driven at a constant speed:
No large fluctuations in displayed speed
|
-
|
FL Wheel Speed
|
Front wheel speed LH
|
Min.: 0 km/h (0 mph), Max.: 327.67 km/h (204 mph)
|
Vehicle stopped:
0 km/h (0 mph)
Vehicle being driven at a constant speed:
No large fluctuations in displayed speed
|
-
|
RR Wheel Speed
|
Rear wheel speed RH
|
Min.: 0 km/h (0 mph), Max.: 327.67 km/h (204 mph)
|
Vehicle stopped:
0 km/h (0 mph)
Vehicle being driven at a constant speed:
No large fluctuations in displayed speed
|
-
|
RL Wheel Speed
|
Rear wheel speed LH
|
Min.: 0 km/h (0 mph), Max.: 327.67 km/h (204 mph)
|
Vehicle stopped:
0 km/h (0 mph)
Vehicle being driven at a constant speed:
No large fluctuations in displayed speed
|
-
|
Steering Angle
|
Steering angle value
(counterclockwise is positive)
|
-
|
-
|
During steering operation:
Changes in proportion with steering wheel rotation
|
Forward and Rearward G
|
Forward and rearward G value
|
-13.107 to 13.106 m/s2
|
-
|
During acceleration/deceleration:
Changes in proportion with acceleration
|
Lateral G
|
Lateral G value
|
-13.107 to 13.106 m/s2
|
-
|
During turning:
Changes in proportion with lateral acceleration
|
Yaw Rate Value
|
Yaw rate value
|
-128.0 to 127.9 deg/s
|
-
|
During turning:
Changes in proportion with yaw
|
Atmospheric Pressure
|
Atmospheric pressure
|
Min.: 0 kPa, Max.: 255 kPa
|
Constant:
Atmosphere pressure
|
-
|
Intake Manifold Absolute Pressure
|
Intake manifold pressure of engine
|
Min.: 0.00 kPa, Max.: 255.00 kPa
|
Ignition switch to ON or engine stopped:
Atmosphere pressure
|
Values less than atmospheric pressure are indicated while the engine is running
|
Ambient Temperature
|
Ambient air temperature
|
Min.: -40°C (-40°F), Max.: 215°C (419°F)
|
Ignition switch to ON:
Same as ambient air temperature
|
Ambient temperature sensor
|
Intake Air Temperature
|
Engine intake air temperature
|
Min.: -40°C (-40°F), Max.: 215°C (419°F)
|
Constant:
Almost same as ambient air temperature
|
-
|
BATT Voltage
|
Auxiliary battery voltage
(Battery ECU assembly power source voltage)
|
Min.: 0.00 V, Max.: 16.00 V
|
11.00 to 15.00 V
|
BATT terminal
|
Smoothed Value of BATT Voltage
|
Smoothed value of auxiliary battery voltage
|
Min.: 0.000 V, Max.: 16.000 V
|
11.000 to 15.000 V
|
Hybrid vehicle control ECU assembly
|
Warmup Cycle Cleared DTC
|
The number of times the engine is warmed up after clearing DTCs
|
Min.: 0, Max.: 255
|
-
|
MIL OFF, engine coolant temperature increases from below 22°C (71.6°F) before starting the engine to above 70°C (158°F) after starting the engine:
Increases once
|
Distance from DTC Cleared
|
Drive distance after clearing DTCs
|
Min.: 0 km (0 mile), Max.: 65535 km (40723 mile)
|
-
|
-
|
Time after DTC Cleared
|
Elapsed time after clearing DTCs
|
Min.: 0 min, Max.: 65535 min
|
-
|
Time elapsed after DTCs are cleared (Not counted when the ignition switch is off).
|
MIL
|
MIL status
|
ON or OFF
|
-
|
-
|
Running Time from MIL ON
|
Running time from MIL on
|
Min.: 0 min, Max.: 65535 min
|
-
|
-
|
Total Distance Traveled
|
Drive total distance
|
Min.: 0, Max.: 16777215
|
-
|
-
|
Total Distance Traveled - Unit
|
Drive total distance unit
|
km or mile
|
-
|
-
|
MIL ON Run Distance
|
Drive distance from MIL on
|
Min.: 0 km (0 mile), Max.: 65535 km (40723 mile)
|
-
|
-
|
Number of Emission DTC
|
Emissions-related DTCs
|
Min.: 0, Max.: 127
|
-
|
-
|
IGB Signal Status
|
IGB signal status
|
ON or OFF
|
Ignition switch to ON or ON (READY):
ON
|
IGB terminal
|
IG2 Signal Status
|
IG2 signal status
|
ON or OFF
|
Ignition switch to ON or ON (READY):
ON
|
IG2 terminal
|
Ready Signal
|
Ready signal status
|
ON or OFF
|
Ignition switch ON (READY):
ON
|
-
|
HV/EV Activate Condition
|
Hybrid vehicle control system power source mode status
|
Normal / Remote Air Control System / Remote
|
Hybrid vehicle control system started using ignition switch:
Normal
Hybrid vehicle control system started using remote air control system function:
Remote Air Control System
Hybrid vehicle control system started using remote starter:
Remote
|
-
|
MG Activate Condition
|
Motor generator control system status
|
ON or OFF
|
Ignition switch to ON or on (READY):
ON
|
-
|
Request Torque for Rear Side
|
Requested rear motor (MGR) torque
|
Min.: -32768 Nm, Max.: 32767 Nm
|
-
|
-
|
DSS Control Status
|
Control status of DSS (Driving Support System)
|
Not Control / Available / Unavailable / Disable
|
-
|
-
|
Generate Torque (Request from DSS)
|
Generated drive torque requested from DSS (Driving Support System)
|
Min.: -4096.00 Nm, Max.: 4095.87 Nm
|
-
|
-
|
Primary Driving Force Adjustment Result
|
Result of adjustment between drive force of DSS (Driving Support System) and drive force requested by accelerator pedal operation
|
Accelerator / DSS
|
Drive force requested by Accelerator pedal operation selected:
Accelerator
Drive force requested by DSS selected:
DSS
|
-
|
SMRG Status
|
Operating state of SMRG
(primary circuit monitor)
|
ON or OFF
|
Ignition switch ON (READY):
ON
|
-
HV battery junction block assembly
-
Wire harness
|
SMRG Control Status
|
Commanded state of SMRG
|
ON or OFF
|
Ignition switch ON (READY):
ON
|
-
HV battery junction block assembly
-
Wire harness
|
SMRB Status
|
Operating state of SMRB
(primary circuit monitor)
|
ON or OFF
|
Ignition switch ON (READY):
ON
|
-
HV battery junction block assembly
-
Wire harness
|
SMRB Control Status
|
Commanded state of SMRB
|
ON or OFF
|
Ignition switch ON (READY):
ON
|
-
HV battery junction block assembly
-
Wire harness
|
SMRP Status
|
Operating state of SMRP
(primary circuit monitor)
|
ON or OFF
|
Immediately after the ignition switch ON (ST-ON) state occurred:
ON
After the above timing:
OFF
|
Cannot be confirmed using the Techstream. Use an oscilloscope.
-
HV battery junction block assembly
-
Wire harness
|
SMRP Control Status
|
Commanded state of SMRP
|
ON or OFF
|
Immediately after the ignition switch ON (ST-ON) state occurred:
ON
After the above timing:
OFF
|
Cannot be confirmed using the Techstream. Use an oscilloscope.
-
HV battery junction block assembly
-
Wire harness
|
Voltage Deviation between before Boosting and after Boosting during SMR Precharge
|
Difference in voltage before boosting and after boosting during system main relay precharge
|
Min.: -3276.8 V, Max.: 3276.7 V
|
-
|
-
|
A/C Consumption Power
|
A/C consumption power
|
Min.: 0.00 kW, Max.: 12.75 kW
|
While the air conditioning system is operating:
0 to 5.00 kW
|
Air conditioning system
|
EV Mode
|
EV mode transition availability
|
ON or OFF
|
In EV mode:
ON
|
-
|
EV Mode Switch
|
EV mode switch (integration control and panel assembly) condition
|
ON or OFF
|
EV mode switch (integration control and panel assembly) being pushed and held:
ON
EV mode switch (integration control and panel assembly) not operated:
OFF
|
Pattern select switch EV mode circuit
|
Sport Mode Switch
|
SPORT mode switch (integration control and panel assembly) condition
|
ON or OFF
|
SPORT mode switch (integration control and panel assembly) being turned and held:
ON
SPORT mode switch (integration control and panel assembly) not operated:
OFF
|
Pattern select switch SPORT mode circuit
|
M/S/B Shift Position Signal
|
Shift position sensor
|
ON or OFF
|
Shift lever in S:
ON
Shift lever in any position other than S:
OFF
|
Shift lever position sensor
|
Normal Mode Switch
|
NORMAL mode switch (integration control and panel assembly) condition
|
ON or OFF
|
NORMAL mode switch (integration control and panel assembly) being pushed and held:
ON
NORMAL mode switch (integration control and panel assembly) not operated:
OFF
|
Pattern select switch NORMAL mode circuit
|
Inter Lock Switch
|
Interlock switch condition
|
ON or OFF
|
Ignition switch to ON, service plug grip not installed:
ON
|
ILK terminal
|
Inter Lock Switch (MG)
|
Interlock switch condition
|
ON or OFF
|
Ignition switch to ON, inverter cover not installed or rear traction motor cable disconnected:
ON
|
Inverter with converter assembly
|
Stop Light Switch
|
Stop light switch assembly condition
|
ON or OFF
|
Brake pedal depressed:
ON
|
-
|
Back Up Light Relay
|
Back up light switch condition
|
ON or OFF
|
Shift lever in R:
ON
|
-
|
VSC/TRC OFF Switch
|
VSC condition
|
OFF / TRC OFF Mode / TRC/VSC OFF Mode
|
-
|
-
|
Auto LSD Switch
|
TRAIL mode switch (integration control and panel assembly) condition
|
ON or OFF
|
TRAIL mode switch (integration control and panel assembly) being pushed and held:
ON
TRAIL mode switch (integration control and panel assembly) not operated:
OFF
|
TRAIL switch circuit
|
Airbag Status (Collision) (CAN)
|
Airbag sensor assembly collision detection
(CAN)
|
Normal / Collision from Back / Airbag Circuit Abnormal / Safing / Collision from Front or Side
|
-
|
-
|
Crank Position
|
Crankshaft position
|
Min.: -128 deg (CA), Max.: 127 deg (CA)
|
-
|
-
|
TC Terminal
|
TC terminal state
|
ON or OFF
|
-
|
Active Test item [Connect the TC and TE1] support data.
|
Body Control with Torque Demand
|
Body Control with Torque Demand status
|
ON or OFF
|
Under the Body Control with Torque Demand:
ON
|
-
|
Generator Revolution
|
Generator (MG1) speed (detected by resolver sensor)
|
Min.: -32768 rpm, Max.: 32767 rpm
|
During charge or discharge:
Varies depending on vehicle operating conditions
|
Generator (MG1) speed is set to obtain requested target engine speed
-
Hybrid vehicle transaxle assembly
-
Inverter with converter assembly
|
Target Generator Torque
|
Generator (MG1) torque request value
|
Min.: -4096.00 Nm, Max.: 4095.87 Nm
|
During charge or discharge:
Varies depending on vehicle operating conditions
|
-
Hybrid vehicle control ECU assembly
-
Hybrid vehicle transaxle assembly
-
Inverter with converter assembly
|
Generator Torque
|
Generator (MG1) torque execution value
|
Min.: -4096.00 Nm, Max.: 4095.87 Nm
|
One second after engine automatically starts with shift lever in P (Condition before engine start: Ignition switch ON (READY), engine stopped, A/C fan speed high and headlights on):
Within +/- 20% of Target Generator Torque
|
-
Hybrid vehicle control ECU assembly
-
Hybrid vehicle transaxle assembly
-
Inverter with converter assembly
|
Motor Revolution
|
Motor (MG2) speed (detected by resolver sensor)
|
Min.: -32768 rpm, Max.: 32767 rpm
|
While driving:
Varies depending on vehicle speed
|
Motor (MG2) speed changes in proportion to vehicle speed. Motor (MG2) speed is not influenced by accelerator pedal opening angle, engine speed or generator (MG1) speed.
-
Hybrid vehicle transaxle assembly
-
Inverter with converter assembly
|
Target Motor Torque
|
Motor (MG2) torque request value
|
Min.: -4096.00 Nm, Max.: 4095.87 Nm
|
While driving:
Varies depending on vehicle operating conditions
|
-
Hybrid vehicle control ECU assembly
-
Hybrid vehicle transaxle assembly
-
Inverter with converter assembly
|
Motor Torque
|
Motor (MG2) torque execution value
|
Min.: -4096.00 Nm, Max.: 4095.87 Nm
|
After full-load acceleration with ignition switch ON (READY) and engine stopped:
Within +/-20% of Target Motor Torque
|
-
Hybrid vehicle control ECU assembly
-
Hybrid vehicle transaxle assembly
-
Inverter with converter assembly
|
Rear Motor Revolution
|
Rear motor (MGR) speed
|
Min.: -32768 rpm, Max.: 32767 rpm
|
While driving:
Varies depending on vehicle speed
|
-
Rear traction motor with transaxle assembly
-
Inverter with converter assembly
|
Target Rear Motor Torque
|
Rear motor (MGR) torque request value
|
Min.: -4096.00 Nm, Max.: 4095.87 Nm
|
While driving:
Varies depending on vehicle operating conditions
|
-
Rear traction motor with transaxle assembly
-
Inverter with converter assembly
-
Hybrid vehicle control ECU assembly
|
Rear Motor Torque
|
Rear motor (MGR) torque execution value
|
Min.: -4096.00 Nm, Max.: 4095.87 Nm
|
After full-load acceleration with ignition switch ON (READY) and engine stopped:
Within +/-20% of target rear motor (MGR) torque
|
-
Rear traction motor with transaxle assembly
-
Inverter with converter assembly
-
Hybrid vehicle control ECU assembly
|
Rear Motor Torque Ratio
|
Rear motor torque ratio
|
-
|
-
|
-
|
Request Motor Regenerative Brake Torque
|
Requested motor (MG2) regenerative braking torque
|
Min.: -4096.00 Nm, Max.: 4095.87 Nm
|
While braking:
Varies depending on vehicle operation conditions
|
When regenerative braking is being performed, current flows from the motor (MG2) to charge the HV battery and braking torque is generated.
-
Electronically controlled brake system
|
Motor Regenerate Brake Execution Torque
|
Motor (MG2) regenerative braking execution torque
|
Min.: -4096.00 Nm, Max.: 4095.87 Nm
|
While braking:
Varies depending on vehicle operation conditions
|
-
Hybrid vehicle control ECU assembly
-
Hybrid vehicle transaxle assembly
-
Inverter with converter assembly
|
Request Rear Motor Regenerative Brake Torque
|
Requested rear motor (MGR) regenerative braking torque
|
Min.: -4096.00 Nm, Max.: 4095.87 Nm
|
Always:
0 Nm
|
Regeneration by rear motor is not performed
|
Rear Motor Regenerate Brake Execution Torque
|
Rear motor (MGR) regenerative braking execution torque
|
Min.: -4096.00 Nm, Max.: 4095.87 Nm
|
Always:
0 Nm
|
Regeneration by rear motor is not performed
|
Generator Temperature
|
Generator (MG1) temperature
|
Min.: -40°C (-40°F), Max.: 215°C (419°F)
|
Vehicle left for 1 day at an ambient temperature of 25°C (77°F):
25°C (77°F)
While driving:
Varies depending on vehicle operating conditions
|
-
|
Generator Temperature Sensor Voltage
|
Generator (MG1) temperature sensor voltage
|
Min.: 0.00 V, Max.: 4.99 V
|
-
|
-
|
Generator Temperature just after IG ON
|
Generator (MG1) temperature soon after ignition switch to ON
|
Min.: -40°C (-40°F), Max.: 215°C (419°F)
|
-
|
-
|
Generator Maximum Temperature
|
Maximum generator (MG1) temperature after ignition switch turned ON in current trip
|
Min.: -40°C (-40°F), Max.: 215°C (419°F)
|
-
|
-
|
Motor Temperature
|
Motor (MG2) temperature
|
Min.: -40°C (-40°F), Max.: 215°C (419°F)
|
Vehicle left for 1 day at an ambient temperature of 25°C (77°F):
25°C (77°F)
While driving:
Varies depending on vehicle operating conditions
|
-
|
Motor Temperature Sensor Voltage
|
Motor (MG2) temperature sensor voltage
|
Min.: 0.00 V, Max.: 4.99 V
|
-
|
-
|
Motor Temperature just after IG ON
|
Motor (MG2) temperature soon after ignition switch to ON
|
Min.: -40°C (-40°F), Max.: 215°C (419°F)
|
-
|
-
|
Motor Maximum Temperature
|
Maximum motor (MG2) temperature after ignition switch to ON in current trip
|
Min.: -40°C (-40°F), Max.: 215°C (419°F)
|
-
|
-
|
Rear Motor Temperature
|
Rear motor (MGR) temperature
|
Min.: -40°C (-40°F), Max.: 215°C (419°F)
|
Vehicle left for 1 day at an ambient temperature of 25°C (77°F):
25°C (77°F)
While driving:
Varies depending on vehicle operating conditions
|
-
|
Rear Motor Temperature Sensor Voltage
|
Rear motor (MGR) temperature sensor voltage
|
Min.: 0 V, Max.: 4.99 V
|
-
|
-
|
Rear Motor Temperature just after IG ON
|
Rear motor (MGR) temperature soon after ignition switch to ON
|
Min.: -40°C (-40°F), Max.: 215°C (419°F)
|
-
|
-
|
Rear Motor Maximum Temperature
|
Maximum rear motor (MGR) temperature after ignition switch to ON in current trip
|
Min.: -40°C (-40°F), Max.: 215°C (419°F)
|
-
|
-
|
Generator Inverter Temperature
|
Generator inverter temperature
|
Min.: 0°C (32°F), Max.: 150°C (302°F)
|
Vehicle left for 1 day at an ambient temperature of 25°C (77°F):
15 to 35°C (59 to 95°F)
While driving at an ambient temperature of 25°C (77°F):
25 to 120°C (77 to 248°F)
|
Inverter with converter assembly
|
Generator Inverter Temperature just after IG ON
|
Generator inverter temperature soon after ignition switch to ON
|
Min.: 0°C (32°F), Max.: 150°C (302°F)
|
-
|
-
|
Generator Inverter Maximum Temperature
|
Maximum generator inverter temperature after ignition switch turned ON in current trip
|
Min.: 0°C (32°F), Max.: 150°C (302°F)
|
-
|
-
|
Motor Inverter Temperature
|
Motor inverter temperature
|
Min.: 0°C (32°F), Max.: 150°C (302°F)
|
Vehicle left for 1 day at an ambient temperature of 25°C (77°F):
15 to 35°C (59 to 95°F)
While driving at an ambient temperature of 25°C (77°F):
25 to 120°C (77 to 248°F)
|
Inverter with converter assembly
|
Motor Inverter Temperature just after IG ON
|
Motor inverter temperature soon after ignition switch to ON
|
Min.: 0°C (32°F), Max.: 150°C (302°F)
|
-
|
-
|
Motor Inverter Maximum Temperature
|
Maximum motor inverter temperature after ignition switch turned ON in current trip
|
Min.: 0°C (32°F), Max.: 150°C (302°F)
|
-
|
-
|
Rear Motor Inverter Temperature
|
Rear motor inverter temperature
|
Min.: 0°C (32°F), Max.: 150°C (302°F)
|
Vehicle left for 1 day at an ambient temperature of 25°C (77°F):
15 to 35°C (59 to 95°F)
While driving at an ambient temperature of 25°C (77°F):
25 to 120°C (77 to 248°F)
|
Inverter with converter assembly
|
Rear Motor Inverter Temperature just after IG ON
|
Rear motor inverter temperature soon after ignition switch to ON
|
Min.: 0°C (32°F), Max.: 150°C (302°F)
|
-
|
-
|
Rear Motor Inverter Temperature before Operation
|
Temperature of rear motor inverter before operation
|
Min.: 0°C (32°F), Max.: 150°C (302°F)
|
-
|
-
|
Rear Motor Inverter Maximum Temperature
|
Maximum rear motor inverter temperature after ignition switch turned ON in current trip
|
Min.: 0°C (32°F), Max.: 150°C (302°F)
|
-
|
-
|
Boosting Converter Temperature (Upper)
|
Boost converter temperature (upper)
|
Min.: 0°C (32°F), Max.: 150°C (302°F)
|
Vehicle left for 1 day at an ambient temperature of 25°C (77°F):
15 to 35°C (59 to 95°F)
While driving at an ambient temperature of 25°C (77°F):
25 to 120°C (77 to 248°F)
|
Inverter with converter assembly
|
Boosting Converter Temperature (Lower)
|
Boost converter temperature (lower)
|
Min.: 0°C (32°F), Max.: 150°C (302°F)
|
Vehicle left for 1 day at an ambient temperature of 25°C (77°F):
15 to 35°C (59 to 95°F)
While driving at an ambient temperature of 25°C (77°F):
25 to 120°C (77 to 248°F)
|
Inverter with converter assembly
|
Boosting Converter Temperature just after IG ON
|
Boost converter temperature soon after ignition switch to ON
|
Min.: 0°C (32°F), Max.: 150°C (302°F)
|
-
|
-
|
Boosting Converter Maximum Temperature
|
Maximum converter temperature after ignition switch turned ON in current trip
|
Min.: 0°C (32°F), Max.: 150°C (302°F)
|
-
|
-
|
Generator Inverter Operation Request
|
Generator inverter operation request
|
Shutdown / 3 Phase ON / Discharge / Insulation Resistance Measurement / Output Torque / Emergency Shutdown / Shutdown during Insulation Resistance Measurement
|
-
|
-
|
Generator Inverter Fail
|
Generator inverter stopped
|
ON or OFF
|
Generator inverter stopped:
ON
Normal:
OFF
|
-
|
Generator Inverter Shutdown Status
|
Generator inverter shutdown status
|
Awake or Shutdown
|
Generator inverter shutdown:
Shutdown
Normal:
Awake
|
-
|
Motor Inverter Operation Request
|
Motor inverter operation request
|
Shutdown / 3 Phase ON / Discharge / Insulation Resistance Measurement / Output Torque / Emergency Shutdown / Shutdown during Insulation Resistance Measurement
|
-
|
-
|
Motor Inverter Fail
|
Motor inverter stopped
|
ON or OFF
|
Motor inverter stopped:
ON
Normal:
OFF
|
-
|
Motor Inverter Shutdown Status
|
Motor inverter shutdown status
|
Awake or Shutdown
|
Motor inverter shutdown:
Shutdown
Normal:
Awake
|
-
|
Rear Motor Inverter Operation Request
|
Rear motor inverter operation request
|
Shutdown / 3 Phase ON / Discharge / Insulation Resistance Measurement / Output Torque / Emergency Shutdown / Shutdown during Insulation Resistance Measurement
|
-
|
-
|
Rear Motor Inverter Fail
|
Rear motor inverter stopped
|
ON or OFF
|
Rear motor inverter stopped:
ON
Normal:
OFF
|
-
|
Rear Motor Inverter Shutdown Status
|
Rear motor inverter shutdown status
|
Awake or Shutdown
|
Rear motor inverter shutdown:
Shutdown
Normal:
Awake
|
-
|
Boosting Converter Operation Request
|
Boost converter operation request
|
Normal / Boosting Stop / Upper Arm ON / Maximum Boosting / Output Torque / Upper Arm Lowering
|
-
|
-
|
Boosting Converter Fail
|
Boost converter stopped
|
ON or OFF
|
Boost converter stopped:
ON
Normal:
OFF
|
-
|
Boosting Converter Shutdown Status
|
Boost converter shutdown status
|
Awake or Shutdown
|
Boost converter shutdown:
Shutdown
Normal:
Awake
|
-
|
Generator Carrier Frequency
|
Generator carrier frequency
|
0.75 kHz / 1.25 kHz / 2.5 kHz / 3.75 kHz / 5 kHz / 10 kHz / Electrical Power Loss Reduction Mode
|
-
|
-
|
Generator Control Mode
|
Generator (MG1) control mode
|
Sine Wave / Overmodulation / Square Wave / Electrical Power Loss Reduction Mode
|
-
|
-
|
Motor Carrier Frequency
|
Motor (MG2) carrier frequency
|
0.75 kHz / 1.25 kHz / 2.5 kHz / 3.75 kHz / 5 kHz / 10 kHz / Electrical Power Loss Reduction Mode
|
-
|
-
|
Motor Control Mode
|
Motor (MG2) control mode
|
Sine Wave / Overmodulation / Square Wave / Electrical Power Loss Reduction Mode
|
-
|
-
|
Rear Motor Carrier Frequency
|
Rear motor (MGR) carrier frequency
|
0.75 kHz / 1.25 kHz / 2.5 kHz / 3.75 kHz / 5 kHz / 10 kHz / Electrical Power Loss Reduction Mode
|
-
|
-
|
Rear Motor Control Mode
|
Rear motor (MGR) control mode
|
Sine Wave / Overmodulation / Square Wave / Electrical Power Loss Reduction Mode
|
PWM: Sine Wave
Variable PWM: Overmodulation
Rectangular wave: Square Wave
|
-
|
Boosting Converter Carrier Frequency
|
Boost converter signal carrier frequency
|
9.55 kHz / 9.13 kHz / 8.71 kHz / 8.29 kHz / 7.87 kHz / 7.45 kHz / 4.8 kHz
|
-
|
-
|
VL-Voltage before Boosting
|
High voltage before it is boosted
|
-
|
Ignition switch ON (READY):
Practically the same as the HV battery voltage
|
-
HV battery
-
Inverter with converter assembly
|
VL-Voltage before Boosting for Rear Motor
|
Rear motor supply voltage before it is boosted
|
-
|
Ignition switch ON (READY):
Practically the same as the HV battery voltage
|
-
HV battery
-
Inverter with converter assembly
|
VH-Voltage after Boosting
|
High voltage after it is boosted
|
-
|
Engine revving up with shift lever in P:
After boosted voltage to below approximately 650 V
|
Inverter with converter assembly
|
Boost Ratio
|
Boost converter boost ratio
|
Min.: 0.0%, Max.: 100.0%
|
-
|
Inverter with converter assembly
|
V Phase Generator Current
|
V phase generator current
|
Min.: -3276.8 A, Max.: 3276.7 A
|
-
|
-
|
W Phase Generator Current
|
W phase generator current
|
Min.: -3276.8 A, Max.: 3276.7 A
|
-
|
-
|
V Phase Motor Current
|
V phase motor current
|
Min.: -3276.8 A, Max.: 3276.7 A
|
-
|
-
|
W Phase Motor Current
|
W phase motor current
|
Min.: -3276.8 A, Max.: 3276.7 A
|
-
|
-
|
V Phase Rear Motor Current
|
V phase rear motor current
|
Min.: -3276.8 A, Max.: 3276.7 A
|
-
|
-
|
W Phase Rear Motor Current
|
W phase rear motor current
|
Min.: -3276.8 A, Max.: 3276.7 A
|
-
|
-
|
Inverter Coolant Water Temperature
|
Inverter coolant temperature
|
Min.: -40°C (-40°F), Max.: 110°C (230°F)
|
Cold start→Fully warmed up:
Gradually rises
System operating normally:
Controlled at 65°C (149°F) or less
|
-
Inverter with converter assembly
-
Inverter water pump assembly
-
Cooling fan system
-
Inverter cooling system
|
Inverter Water Pump
|
Inverter water pump assembly status
|
ON or OFF
|
During Active Test:
ON
|
Active Test item [Activate the Inverter Water Pump] support data.
-
Inverter water pump assembly
|
Inverter Water Pump Duty Ratio
|
Inverter water pump motor driver request duty
|
Min.: 0.00%, Max.: 100.00%
|
Ignition switch ON (READY):
40 to 85%
|
Hybrid vehicle control ECU assembly
|
Inverter Water Pump Revolution
|
Inverter water pump assembly speed
|
Min.: 0 rpm, Max.: 15000 rpm
|
Ignition switch ON (READY):
1051 to 8617 rpm
|
When the inverter water pump assembly is not operating:
200 rpm or less
|
Overvoltage Input to Inverter
|
Overvoltage detection into inverter
|
ON or OFF
|
Overvoltage is detected into inverter:
ON
Normal:
OFF
|
-
|
Inverter Emergency Shutdown (Main CPU)
|
Inverter emergency shutdown
|
ON or OFF
|
Inverter emergency shutdown:
ON
Normal:
OFF
|
-
|
Inverter Emergency Shutdown (Sub CPU)
|
Inverter emergency shutdown
|
ON or OFF
|
Inverter emergency shutdown:
ON
Normal:
OFF
|
-
|
Inverter Input Current
|
Inverter input current
|
Min.: -3276.8 A, Max.: 3276.7 A
|
-
|
-
|
Overvoltage Input to Boosting Converter
|
Overvoltage detection into boost converter
|
ON or OFF
|
Overvoltage is detected into boost converter:
ON
Normal:
OFF
|
-
|
Motor/Generator Reactor Current before SMR Precharge
|
Reactor current before system main relay precharge
|
Min.: -3276.8 A, Max.: 3276.7 A
|
-
|
-
|
Motor/Generator Reactor Maximum Current during SMR Precharge
|
Highest reactor current during system main relay precharge
|
Min.: -3276.8 A, Max.: 3276.7 A
|
-
|
-
|
Motor/Generator Reactor Current-Carrying Status during SMR Precharge
|
Current flowing through reactor during system main relay precharge
|
Indefinite / Definite
|
-
|
-
|
Motor/Generator Reactor Noncurrent-Carrying Status during SMR Precharge
|
Current not flowing through reactor during system main relay precharge
|
Indefinite / Definite
|
-
|
-
|
Hybrid/EV Battery SOC
|
HV battery state of charge
|
Min.: 0.00%, Max.: 100.00%
|
Constant:
0.00 to 100.00%
|
Primary calculated from charging and discharging amperage
-
HV battery
-
Battery ECU assembly
-
Hybrid vehicle control ECU assembly
|
Hybrid/EV Battery SOC of Immediately after IG ON
|
HV battery state of charge soon after ignition switch to ON
|
Min.: 0.0%, Max.: 100.0%
|
-
|
-
|
Hybrid/EV Battery Maximum SOC
|
Maximum SOC after ignition switch turned ON in current trip
|
Min.: 0.0%, Max.: 100.0%
|
-
|
-
|
Hybrid/EV Battery Minimum SOC
|
Minimum SOC after ignition switch turned ON in current trip
|
Min.: 0.0%, Max.: 100.0%
|
-
|
-
|
Hybrid/EV Battery Voltage
|
HV battery voltage
|
Min.: 0.0 V, Max.: 1023.98 V
|
Ignition switch ON (READY):
150.0 to 300.0 V
|
-
HV battery
-
Battery ECU assembly
-
Hybrid vehicle control ECU assembly
|
Hybrid/EV Battery Current
|
HV battery current
|
Min.: -3276.8 A, Max.: 3276.7 A
|
Ignition switch ON (READY):
-200.0 to 200.0 A
|
-
HV battery
-
Power cable
-
Inverter with converter assembly
-
Battery current sensor
|
Hybrid/EV Battery Current for Driving Control
|
Hybrid battery current for driving control
|
Min.: -327.68 A, Max.: 327.67 A
|
-
|
-
Discharging amperage is indicated by a positive value
-
Charging amperage is indicated by a negative value
|
Hybrid/EV Battery Cooling Fan Low Speed Request
|
Battery cooling blower assembly Lo speed requested
|
ON or OFF
|
Constant:
ON or OFF
|
-
|
Short Wave Highest Value Level
|
Waveform voltage level in abnormal insulation detection circuit in battery ECU assembly
|
Not Judge / Normal / Insulation Lower LV2 / Insulation Lower LV3
|
Judgment not completed:
Not Judge
Normal:
Normal condition
Medium low level:
Insulation Lower LV2
Severe low level:
Insulation Lower LV3
|
High voltage circuit
|
Insulation Resistance Division Check Completion using Rear Motor Inv
|
Insulation resistance division check completion using rear motor inverter
|
Not Complete / Complete
|
Decreased insulation resistance judgment for rear motor inverter has completed:
Complete
|
Check the value of Data List item "Short Wave Highest Value Level" before and after the rear motor inverter is shut down.
|
Insulation Resistance Division Check Completion using MG Inv
|
Insulation resistance division check completion using MG inverter
|
Not Complete / Complete
|
Decreased insulation resistance judgment for motor and generator inverter has completed:
Complete
|
After turning the ignition switch from ON (READY) to off, compare the value of Data List item "Short Wave Highest Value Level" before and after the motor and generator inverter are shut down.
|
Insulation Resistance Division Check Completion using A/C Inv
|
Insulation resistance division check completion using A/C inverter
|
Not Complete / Complete
|
Decreased insulation resistance judgment for the air conditioning inverter has completed:
Complete
|
Check the value of Data List item "Short Wave Highest Value Level" before and after the air conditioning inverter is shut down.
|
Insulation Resistance Division Check Completion using SMR
|
Insulation resistance division check completion using SMR
|
Not Complete / Complete
|
Decreased insulation resistance judgment for the system main relays has completed:
Complete
|
Check the value of Data List item "Short Wave Highest Value Level" before and after the system main relays are turned off.
|
Short Wave Highest Value Availability just after Rear Motor Inv On/Off
|
Short wave highest value availability just after rear motor inverter on/off
|
No or Yes
|
The value of Data List item "Short Wave Highest Value Level" cannot be checked immediately after the rear motor inverter are turned on/off:
No
|
-
|
Short Wave Highest Value Availability just after MG Inv On/Off
|
Short wave highest value availability just after MG inverter on/off
|
No or Yes
|
The value of Data List item "Short Wave Highest Value Level" cannot be checked immediately after the motor and generator inverter are turned on/off:
No
|
-
|
Short Wave Highest Value Availability just after A/C Inv On/Off
|
Short wave highest value availability just after A/C inverter on/off
|
No or Yes
|
The value of Data List item "Short Wave Highest Value Level" cannot be checked immediately after air conditioning inverter turned on/off:
No
|
-
|
Short Wave Highest Value Availability just after SMR On/Off
|
Short wave highest value availability just after SMR on/off
|
No or Yes
|
The value of Data List item "Short Wave Highest Value Level" cannot be checked immediately after system main relays turned on/off:
No
|
-
|
Immobiliser Communication
|
Immobiliser communication line status
|
ON or OFF
|
-
|
-
|
Permit Start by Immobiliser
|
Status of starting permission by immobiliser (immobiliser to hybrid vehicle control ECU assembly)
|
No Judgment / OK / NG
|
-
|
-
|
Auxiliary Battery Voltage
|
Auxiliary battery voltage
|
Min.: 0.00 V, Max.: 16.00 V
|
Always:
11.00 to 15.00 V
|
When ignition switch ON (READY): approx. 12.5 to 15.0 V.
When ignition switch to ON: same as auxiliary battery voltage (approx. 12 V).
If the voltage becomes 11 V or less when the ignition switch is ON (READY), the hybrid vehicle control ECU assembly stores inverter with converter assembly DTCs. If the voltage becomes 9.5 V or less, the ignition switch will not be able to be turned on (READY).
-
Auxiliary battery
-
Hybrid vehicle converter
|
Auxiliary Battery Voltage just before SMR Precharge
|
Auxiliary battery voltage just before SMR precharge
|
Min.: 0.00 V, Max.: 79.99 V
|
-
|
-
|
Auxiliary Battery Current
|
Auxiliary battery current
|
Min.: -125.00 A, Max.: 124.99 A
|
-
|
-
|
Smoothed Value of Auxiliary Battery Temperature
|
Smoothed value of auxiliary battery temperature
|
Min.: -40.0°C (-40.0°F), Max.: 6513.5°C (11756.3°F)
|
-
|
-
|
Auxiliary Battery Voltage Low Times
|
Auxiliary battery voltage low times
|
Min.: 0, Max.: 255
|
-
|
-
|
Auxiliary Battery Voltage at Low Voltage Checking Initiation
|
Voltage of auxiliary battery voltage low judgment
|
-
|
-
|
-
|
Auxiliary Battery Charging Integrated Current
|
Cumulative battery charging integrated current value since vehicle was built
|
Min.: 0.0 Ah, Max.: 429496729.5 Ah
|
-
|
-
|
Auxiliary Battery Discharging Integrated Current
|
Cumulative battery discharging integrated current value since vehicle was built
|
Min.: 0.0 Ah, Max.: 429496729.5 Ah
|
-
|
-
|
Auxiliary Battery Capacity after IG ON
|
Auxiliary battery capacity after ignition switch to ON
|
Min.: -128 Ah, Max.: 127 Ah
|
-
|
-
|
Auxiliary Battery Capacity after IG OFF
|
Auxiliary battery capacity after ignition switch off
|
Min.: -128 Ah, Max.: 127 Ah
|
-
|
-
|
Auxiliary Battery Status of Full Charge
|
Auxiliary battery status when full charge
|
Min.: 0.0 Ah, Max.: 127.5 Ah
|
-
|
-
|
Auxiliary Battery Charging Rate Accuracy
|
Auxiliary battery charging rate accuracy
|
Low / Middle / High / Disable
|
-
|
-
|
Auxiliary Battery Dark Current
|
Auxiliary battery dark current
|
Min.: 0 mA, Max.: 65535 mA
|
-
|
-
|
Auxiliary Battery Sensor Sleep Time
|
Auxiliary battery sensor sleep time
|
Min.: 0 h, Max.: 255 h
|
-
|
-
|
Integrated Ready ON Time
|
Cumulative time ignition switch has been on (READY) since vehicle was built
|
Min.: 0 hour, Max.: 65535 hour
|
-
|
-
|
Number of Long Term Leaving with IG OFF
|
Number of times ignition switch not changed from off for long period of time (1440 hours (60 days))
|
Min.: 0, Max.: 255
|
-
|
-
|
Auxiliary Battery Integrated Thermal Load
|
Cumulative auxiliary battery thermal load since vehicle was built
|
Min.: 0, Max.: 4294967295
|
-
|
-
|
Total Distance Indicated after Long Term Leaving with IG OFF (1st)
|
Cumulative distance before 1st long term ignition switch off period of time (1440 hours (60 days))
|
Min.: 0 km, Max: 131070 km
|
-
|
-
|
Total Distance Indicated after Long Term Leaving with IG OFF (2nd)
|
Cumulative distance before 2nd long term ignition switch off period of time (1440 hours (60 days))
|
Min.: 0 km, Max: 131070 km
|
-
|
-
|
Total Distance Indicated after Long Term Leaving with IG OFF (3rd)
|
Cumulative distance before 3rd long term ignition switch off period of time (1440 hours (60 days))
|
Min.: 0 km, Max: 131070 km
|
-
|
-
|
Time of Long Term Leaving with IG OFF (1st)
|
Number of days of 1st long term ignition switch off period of time (1440 hours (60 days))
|
Min.: 0 day, Max.: 255 day
|
-
|
-
|
Time of Long Term Leaving with IG OFF (2nd)
|
Number of days of 2nd long term ignition switch off period of time (1440 hours (60 days))
|
Min.: 0 day, Max.: 255 day
|
-
|
-
|
Time of Long Term Leaving with IG OFF (3rd)
|
Number of days of 3rd long term ignition switch off period of time (1440 hours (60 days))
|
Min.: 0 day, Max.: 255 day
|
-
|
-
|
Auxiliary Battery Average Current during IG OFF 1 Trip before
|
Average auxiliary battery current when ignition switch off 1 trip before
|
Min.: -30.000 A, Max: 1.998 A
|
-
|
-
|
Auxiliary Battery Average Current during IG OFF 2 Trip before
|
Average auxiliary battery current when ignition switch off 2 trip before
|
Min.: -30.000 A, Max: 1.998 A
|
-
|
-
|
Auxiliary Battery Average Current during IG OFF 3 Trip before
|
Average auxiliary battery current when ignition switch off 3 trip before
|
Min.: -30.000 A, Max: 1.998 A
|
-
|
-
|
Auxiliary Battery Average Current during IG OFF 4 Trip before
|
Average auxiliary battery current when ignition switch off 4 trip before
|
Min.: -30.000 A, Max: 1.998 A
|
-
|
-
|
Auxiliary Battery Average Current during IG OFF 5 Trip before
|
Average auxiliary battery current when ignition switch off 5 trip before
|
Min.: -30.000 A, Max: 1.998 A
|
-
|
-
|
Total Distance Up to 1 Trip before
|
Cumulative distance traveled 1 trip before
|
Min.: 0 km, Max: 131070 km
|
-
|
-
|
Total Distance Up to 2 Trip before
|
Cumulative distance traveled 2 trip before
|
Min.: 0 km, Max: 131070 km
|
-
|
-
|
Total Distance Up to 3 Trip before
|
Cumulative distance traveled 3 trip before
|
Min.: 0 km, Max: 131070 km
|
-
|
-
|
Total Distance Up to 4 Trip before
|
Cumulative distance traveled 4 trip before
|
Min.: 0 km, Max: 131070 km
|
-
|
-
|
Total Distance Up to 5 Trip before
|
Cumulative distance traveled 5 trip before
|
Min.: 0 km, Max: 131070 km
|
-
|
-
|
IG OFF Time before 1 trip
|
Number of days ignition switch was off 1 trip before
|
Min.: 0 day, Max.: 255 day
|
-
|
-
|
IG OFF Time before 2 trip
|
Number of days ignition switch was off 2 trip before
|
Min.: 0 day, Max.: 255 day
|
-
|
-
|
IG OFF Time before 3 trip
|
Number of days ignition switch was off 3 trip before
|
Min.: 0 day, Max.: 255 day
|
-
|
-
|
IG OFF Time before 4 trip
|
Number of days ignition switch was off 4 trip before
|
Min.: 0 day, Max.: 255 day
|
-
|
-
|
IG OFF Time before 5 trip
|
Number of days ignition switch was off 5 trip before
|
Min.: 0 day, Max.: 255 day
|
-
|
-
|
IG ON Time Up to 1 trip before
|
Time ignition switch was ON 1 trip before
|
Min.: 0 min, Max.: 510 min
|
-
|
-
|
IG ON Time Up to 2 trip before
|
Time ignition switch was ON 2 trip before
|
Min.: 0 min, Max.: 510 min
|
-
|
-
|
IG ON Time Up to 3 trip before
|
Time ignition switch was ON 3 trip before
|
Min.: 0 min, Max.: 510 min
|
-
|
-
|
IG ON Time Up to 4 trip before
|
Time ignition switch was ON 4 trip before
|
Min.: 0 min, Max.: 510 min
|
-
|
-
|
IG ON Time Up to 5 trip before
|
Time ignition switch was ON 5 trip before
|
Min.: 0 min, Max.: 510 min
|
-
|
-
|
Ready ON Time Up to 1 trip before
|
Time ignition switch was ON (READY) 1 trip before
|
Min.: 0 min, Max.: 510 min
|
-
|
-
|
Ready ON Time Up to 2 trip before
|
Time ignition switch was ON (READY) 2 trip before
|
Min.: 0 min, Max.: 510 min
|
-
|
-
|
Ready ON Time Up to 3 trip before
|
Time ignition switch was ON (READY) 3 trip before
|
Min.: 0 min, Max.: 510 min
|
-
|
-
|
Ready ON Time Up to 4 trip before
|
Time ignition switch was ON (READY) 4 trip before
|
Min.: 0 min, Max.: 510 min
|
-
|
-
|
Ready ON Time Up to 5 trip before
|
Time ignition switch was ON (READY) 5 trip before
|
Min.: 0 min, Max.: 510 min
|
-
|
-
|
Power Feeding Electrical Using Status
|
Usage state of power supplied from external power source charging
|
Charge Sustaining Mode/Not PHV / Charge Depleting Mode / Charge Increasing Mode / Ready OFF
|
-
|
-
|