                               (a) Measure the resistance according to the value(s) in the table below. 
                              Standard Resistance:  
                              
                                 
                                 
                                 
                                 
                                    
                                       | 
                                           Tester Connection 
                                        | 
                                       
                                           Condition 
                                        | 
                                       
                                           Specified Condition 
                                        | 
                                     
                                 
                                 
                                    
                                       | 
                                           1 (+UL) - 2 (+UM) 
                                        | 
                                       
                                           20°C (68°F) 
                                        | 
                                       
                                           29 to 33 Ω 
                                        | 
                                     
                                    
                                       | 
                                           3 (+UN) - 4 (+UP) 
                                        | 
                                     
                                 
                               
                              If the result is not as specified, replace the fuel vapor containment valve (close tank with bolt valve assembly). 
                            | 
                           
                              
                                 
                                    
                                        
                                     | 
                                  
                                 
                                    
                                       
                                          
                                             
                                             
                                          
                                          
                                             
                                                | 
                                                    *a 
                                                 | 
                                                
                                                    Component without wire harness connected 
                                                   (Fuel Vapor Containment Valve (Close Tank with Bolt Valve Assembly)) 
                                                 | 
                                              
                                          
                                        
                                     | 
                                  
                               
                            |