                           Last Modified: 05-08-2025 | 
                        6.11:8.1.0  | 
                        
                           Doc ID: RM1000000021U3X | 
                      
                     
                        | 
                           Model Year Start: 2022 | 
                        
                           Model: RAV4 HV | 
                        
                           Prod Date Range: [12/2021 -                    
                                       ] | 
                      
                     
                        | 
                           Title: A25A-FXS (COOLING): THERMOSTAT: INSPECTION; 2022 - 2025 MY RAV4 HV [12/2021 -        ] | 
                      
                   
                  INSPECTION
                   
                  PROCEDURE
                   
                  1. INSPECT WATER INLET WITH THERMOSTAT SUB-ASSEMBLY 
                  
                     CAUTION: 
                     
                        - 
Do not put your hands into the water that has been heated for the inspection.
 
                      
                   
                  
                     
                        - 
Touching the heated water could result in burns.
 
                      
                   
                   
                  HINT: 
                  The valve opening temperature is inscribed on the water inlet with thermostat sub-assembly. 
                   
                  (a) Immerse the water inlet with thermostat sub-assembly in water and then gradually heat the water. 
                  (b) Check that the valve of the water inlet with thermostat sub-assembly opens at the specified temperature. 
                  Standard valve opening temperature:  
                  80 to 84°C (176 to 183°F) 
                  If the result is not as specified, replace the water inlet with thermostat sub-assembly. 
                  
                     
                        
                           | 
                               (c) Check the valve lift. 
                              Standard valve lift:  
                              8.0 mm (0.315 in.) or more at 95°C (203°F) 
                              If the result is not as specified, replace the water inlet with thermostat sub-assembly. 
                            | 
                           
                              
                            | 
                         
                     
                   
                  (d) Check that the valve is fully closed when the water inlet with thermostat sub-assembly is at low temperatures (below 72°C (162°F)). 
                  If it is not fully closed, replace the water inlet with thermostat sub-assembly. 
                  
                |