(1) Apply auxiliary battery voltage to the trip switch and check that it illuminates.
OK:
Measurement Condition
|
Specified Condition
|
Auxiliary battery positive (+) → Terminal 6 (ILL+)
Auxiliary battery negative (-) → Terminal 1 (ILL-)
|
Illuminates
|
If the result is not as specified, replace the trip switch.
|
|
*a
|
Component without harness connected
(Trip Switch)
|
|
|