Last Modified: 01-30-2024 |
6.11:8.1.0 |
Doc ID: RM1000000026Q2T |
Model Year Start: 2023 |
Model: RAV4 HV |
Prod Date Range: [10/2022 - 10/2023] |
Title: HYBRID / BATTERY CONTROL: BATTERY VOLTAGE SENSOR: REMOVAL; 2023 MY RAV4 HV [10/2022 - 10/2023] |
REMOVAL
CAUTION / NOTICE / HINT
The necessary procedures (adjustment, calibration, initialization, or registration) that must be performed after parts are removed and installed, or replaced during battery voltage sensor removal/installation are shown below.
Necessary Procedures After Parts Removed/Installed/Replaced
Replaced Part or Performed Procedure
|
Necessary Procedures
|
Effect/Inoperative Function when Necessary Procedures not Performed
|
Link
|
Auxiliary battery terminal is disconnected/reconnected
|
Perform steering sensor zero point calibration
|
Lane control system
|
|
Parking support brake system*
|
Pre-collision system
|
Reset back door close position
|
power back door system
|
|
Back door lock initialization
|
power door lock control system
|
|
Replacement of HV battery
|
Battery status info update
|
HV battery status information cannot be updated
|
|
NOTICE:
-
The type of battery voltage sensor to be used varies depending on the vehicle model.
-
The type of battery voltage sensor can be confirmed by the color of the label.
-
If the wrong type of battery voltage sensor is installed, the ignition switch cannot be turned on (READY).
-
After installing the battery voltage sensor, perform the following to check that the ignition switch can be turned on (READY).
-
Turn the ignition switch on (READY).
-
Turn the ignition switch off and wait for 30 seconds or more.
-
Turn the ignition switch on (READY) again.
-
After the ignition switch is turned off, the audio and visual system records various types of memory and settings. As a result, after turning the ignition switch off, make sure to wait at least 2 minutes before disconnecting the cable from the negative (-) auxiliary battery terminal.
-
When the cable is disconnected from the negative (-) auxiliary battery terminal and the security lock setting has been enabled, multi-display operations will be disabled upon next startup unless the password is entered. Be sure to check the security lock setting before disconnecting the cable from the negative (-) auxiliary battery terminal.
PROCEDURE
1. PRECAUTION
NOTICE:
After turning the ignition switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.
2. REMOVE HV BATTERY
Click here
3. REMOVE UPPER HV BATTERY COVER SUB-ASSEMBLY
CAUTION:
Be sure to wear insulated gloves and protective goggles.
(a) Remove the 8 bolts, 4 nuts and upper HV battery cover sub-assembly from the HV battery.
|
|
4. REMOVE NO. 1 HV BATTERY SHIELD PANEL
CAUTION:
Be sure to wear insulated gloves and protective goggles.
(b) Disconnect the battery voltage sensor connector.
(c) Remove the bolt and nut.
|
|
(d) Remove the No. 1 HV battery shield from the HV battery.
|
Remove in this Direction
|
5. REMOVE BATTERY VOLTAGE SENSOR
CAUTION:
Be sure to wear insulated gloves and protective goggles.
(a) Disconnect the battery voltage sensor connector.
NOTICE:
Insulate each disconnected high-voltage connector with insulating tape. Wrap the connector from the wire harness side to the end of the connector.
|
|
(b) Remove the bolt and battery voltage sensor from the HV battery.
NOTICE:
If the battery voltage sensor has been struck or dropped, replace it.
|
|
|