Last Modified: 01-30-2024 |
6.11:8.1.0 |
Doc ID: RM1000000026S2X |
Model Year Start: 2019 |
Model: RAV4 HV |
Prod Date Range: [11/2018 - 08/2020] |
Title: HYBRID / BATTERY CONTROL: HYBRID CONTROL SYSTEM (for 2WD with NICKEL METAL HYDRIDE BATTERY): P0B3B14,...,P308A13; Hybrid/EV Battery Voltage Sensor "A" Circuit Short to Ground or Open; 2019 - 2020 MY RAV4 HV [11/2018 - 08/2020] |
DTC
|
P0B3B14
|
Hybrid/EV Battery Voltage Sensor "A" Circuit Short to Ground or Open
|
DTC
|
P0B4014
|
Hybrid/EV Battery Voltage Sensor "B" Circuit Short to Ground or Open
|
DTC
|
P0B4514
|
Hybrid/EV Battery Voltage Sensor "C" Circuit Short to Ground or Open
|
DTC
|
P0B4A14
|
Hybrid/EV Battery Voltage Sensor "D" Circuit Short to Ground or Open
|
DTC
|
P0B4F14
|
Hybrid/EV Battery Voltage Sensor "E" Circuit Short to Ground or Open
|
DTC
|
P0B5414
|
Hybrid/EV Battery Voltage Sensor "F" Circuit Short to Ground or Open
|
DTC
|
P0B5914
|
Hybrid/EV Battery Voltage Sensor "G" Circuit Short to Ground or Open
|
DTC
|
P0B5E14
|
Hybrid/EV Battery Voltage Sensor "H" Circuit Short to Ground or Open
|
DTC
|
P0B6314
|
Hybrid/EV Battery Voltage Sensor "I" Circuit Short to Ground or Open
|
DTC
|
P0B6814
|
Hybrid/EV Battery Voltage Sensor "J" Circuit Short to Ground or Open
|
DTC
|
P0B6D14
|
Hybrid/EV Battery Voltage Sensor "K" Circuit Short to Ground or Open
|
DTC
|
P0B7214
|
Hybrid/EV Battery Voltage Sensor "L" Circuit Short to Ground or Open
|
DTC
|
P308A13
|
Hybrid/EV Battery Voltage Sensor All Circuit Open
|
DESCRIPTION
Refer to the description for DTC P1AC000.
Click here
DTC No.
|
Detection Item
|
DTC Detection Condition
|
Trouble Area
|
MIL
|
Warning Indicate
|
P0B3B14
|
Hybrid/EV Battery Voltage Sensor "A" Circuit Short to Ground or Open
|
The battery block voltage detection line has a malfunction and any of the battery block voltages become lower than the specified value (open).
(1 trip detection logic)
|
-
Battery voltage sensor
-
HV battery
|
Comes on
|
Master Warning:
Comes on
|
P0B4014
|
Hybrid/EV Battery Voltage Sensor "B" Circuit Short to Ground or Open
|
The battery block voltage detection line has a malfunction and any of the battery block voltages become lower than the specified value (open).
(1 trip detection logic)
|
-
Battery voltage sensor
-
HV battery
|
Comes on
|
Master Warning:
Comes on
|
P0B4514
|
Hybrid/EV Battery Voltage Sensor "C" Circuit Short to Ground or Open
|
The battery block voltage detection line has a malfunction and any of the battery block voltages become lower than the specified value (open).
(1 trip detection logic)
|
-
Battery voltage sensor
-
HV battery
|
Comes on
|
Master Warning:
Comes on
|
P0B4A14
|
Hybrid/EV Battery Voltage Sensor "D" Circuit Short to Ground or Open
|
The battery block voltage detection line has a malfunction and any of the battery block voltages become lower than the specified value (open).
(1 trip detection logic)
|
-
Battery voltage sensor
-
HV battery
|
Comes on
|
Master Warning:
Comes on
|
P0B4F14
|
Hybrid/EV Battery Voltage Sensor "E" Circuit Short to Ground or Open
|
The battery block voltage detection line has a malfunction and any of the battery block voltages become lower than the specified value (open).
(1 trip detection logic)
|
-
Battery voltage sensor
-
HV battery
|
Comes on
|
Master Warning:
Comes on
|
P0B5414
|
Hybrid/EV Battery Voltage Sensor "F" Circuit Short to Ground or Open
|
The battery block voltage detection line has a malfunction and any of the battery block voltages become lower than the specified value (open).
(1 trip detection logic)
|
-
Battery voltage sensor
-
HV battery
|
Comes on
|
Master Warning:
Comes on
|
P0B5914
|
Hybrid/EV Battery Voltage Sensor "G" Circuit Short to Ground or Open
|
The battery block voltage detection line has a malfunction and any of the battery block voltages become lower than the specified value (open).
(1 trip detection logic)
|
-
Battery voltage sensor
-
HV battery
|
Comes on
|
Master Warning:
Comes on
|
P0B5E14
|
Hybrid/EV Battery Voltage Sensor "H" Circuit Short to Ground or Open
|
The battery block voltage detection line has a malfunction and any of the battery block voltages become lower than the specified value (open).
(1 trip detection logic)
|
-
Battery voltage sensor
-
HV battery
|
Comes on
|
Master Warning:
Comes on
|
P0B6314
|
Hybrid/EV Battery Voltage Sensor "I" Circuit Short to Ground or Open
|
The battery block voltage detection line has a malfunction and any of the battery block voltages become lower than the specified value (open).
(1 trip detection logic)
|
-
Battery voltage sensor
-
HV battery
|
Comes on
|
Master Warning:
Comes on
|
P0B6814
|
Hybrid/EV Battery Voltage Sensor "J" Circuit Short to Ground or Open
|
The battery block voltage detection line has a malfunction and any of the battery block voltages become lower than the specified value (open).
(1 trip detection logic)
|
-
Battery voltage sensor
-
HV battery
|
Comes on
|
Master Warning:
Comes on
|
P0B6D14
|
Hybrid/EV Battery Voltage Sensor "K" Circuit Short to Ground or Open
|
The battery block voltage detection line has a malfunction and any of the battery block voltages become lower than the specified value (open).
(1 trip detection logic)
|
-
Battery voltage sensor
-
HV battery
|
Comes on
|
Master Warning:
Comes on
|
P0B7214
|
Hybrid/EV Battery Voltage Sensor "L" Circuit Short to Ground or Open
|
The battery block voltage detection line has a malfunction and any of the battery block voltages become lower than the specified value (open).
(1 trip detection logic)
|
-
Battery voltage sensor
-
HV battery
|
Comes on
|
Master Warning:
Comes on
|
P308A13
|
Hybrid/EV Battery Voltage Sensor All Circuit Open
|
The battery block voltage detection line is open (all blocks) or all battery block voltages become lower than the specified value (possibility of open or loosely connected connector).
(1 trip detection logic)
|
-
Battery voltage sensor
-
HV battery
|
Comes on
|
Master Warning:
Comes on
|
HINT:
Hybrid Battery Block 1 to 11 Voltage values smaller than 2.0 V may not be shown in the Data List because a fail-safe value is substituted.
Related Data List
DTC No.
|
Data List
|
P0B3B14
|
Hybrid Battery Block 1 to 11 Voltage*1
|
P0B4014
|
P0B4514
|
P0B4A14
|
P0B4F14
|
P0B5414
|
P0B5914
|
P0B5E14
|
P0B6314
|
P0B6814
|
P0B6D14
|
P0B7214
|
P308A13
|
-
Hybrid Battery Voltage
-
Hybrid Battery Block 1 to 11 Voltage*1
|
HINT:
-
*1: Under normal conditions, the values of Hybrid Battery Block 1, 2, 9, 10 and 11 Voltage will be approximately 16 V and Hybrid Battery Block 3, 4, 5, 6, 7 and 8 Voltage will be approximately 32 V.
-
If there is a short or open in a battery block voltage detection line, the value of Hybrid Battery Block Voltage for the corresponding battery block will be lower than 8 V.
CONFIRMATION DRIVING PATTERN
HINT:
After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.
Click here
-
Connect the Techstream to the DLC3.
-
Turn the power switch on (IG) and turn the Techstream on.
-
Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
-
Turn the power switch off and wait for 2 minutes or more.
-
Turn the power switch on (IG) and turn the Techstream on.
-
With power switch on (IG) and wait for 20 seconds or more.
-
Enter the following menus: Powertrain / Hybrid Control / Utility / All Readiness.
-
Check the DTC judgment result.
HINT:
-
If the judgment result shows NORMAL, the system is normal.
-
If the judgment result shows ABNORMAL, the system has a malfunction.
-
If the judgment result shows INCOMPLETE, perform driving pattern again.
WIRING DIAGRAM
CAUTION / NOTICE / HINT
CAUTION:
-
Before the following operations are conducted, take precautions to prevent electric shock by turning the power switch off, wearing insulated gloves, and removing the service plug grip from HV battery.
-
Inspecting the high-voltage system
-
Disconnecting the low voltage connector of the inverter with converter assembly
-
Disconnecting the low voltage connector of the HV battery
-
To prevent electric shock, make sure to remove the service plug grip to cut off the high voltage circuit before servicing the vehicle.
-
After removing the service plug grip from the HV battery, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
-
After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.
Click here
HINT:
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.
*a
|
Without waiting for 10 minutes
|
-
Make sure to insulate the high-voltage connectors and terminals of the HV battery with insulating tape after removing it.
If the HV battery stored without insulating the connectors and terminals, electric shock or fire may result.
-
When disposing of an HV battery, make sure to return it through an authorized collection agent who is capable of handling it safely. If the HV battery is returned via the manufacturer specified route, it will be returned properly and in a safe manner by an authorized collection agent.
*a
|
Dealer
|
*b
|
Battery Collection Agent
|
-
Accidents such as electric shock may result if the HV battery is disposed of improperly or abandoned. Therefore, make sure to return all HV batteries through an authorized collection agent.
-
After removing the HV battery, keep it away from water. Exposure to water may cause the HV battery to produce heat, resulting in a fire.
NOTICE:
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.
Click here
PROCEDURE
1.
|
CHECK DTC OUTPUT (HYBRID CONTROL)
|
(a) Connect the Techstream to the DLC3.
(b) Turn the power switch on (IG).
(c) Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
(d) Check and record any HV system DTCs and freeze frame data.
(e) Read output DTCs.
Powertrain > Hybrid Control > Trouble Codes
Result
|
Proceed to
|
"P0A9563, P0AFC00, P0AFC96 or P308A12" is not output.
|
A
|
"P0A9563, P0AFC00, P0AFC96 or P308A12" is also output.
|
B
|
(f) Turn the power switch off.
A
|
|
|
2.
|
CHECK CONNECTOR CONNECTION CONDITION
|
Click here
NG |
|
CONNECT SECURELY
|
OK
|
|
|
3.
|
CHECK BATTERY VOLTAGE SENSOR (GA0 - VB17)
|
CAUTION:
Be sure to wear insulated gloves.
(a) Check that the service plug grip is not installed.
NOTICE:
After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
(b) Remove the No. 1 HV battery shield panel.
Click here
(c) Measure the voltage according to the value(s) in the table below.
Standard Voltage:
Tester Connection
|
Condition
|
Specified Condition
|
c1-18 (GB0) (-) - c1-9 (VB1) (+)
|
Always
|
14.4 to 16.8 V
|
c1-9 (VB1) (-) - c1-17 (VB2) (+)
|
Always
|
14.4 to 16.8 V
|
c1-17 (VB2) (-) - c1-16 (VB4) (+)
|
Always
|
28.8 to 33.6 V
|
c1-16 (VB4) (-) - c1-15 (VB6) (+)
|
Always
|
28.8 to 33.6 V
|
c1-15 (VB6) (-) - c1-14 (VB8) (+)
|
Always
|
28.8 to 33.6 V
|
c1-14 (VB8) (-) - c1-13 (VB10) (+)
|
Always
|
28.8 to 33.6 V
|
c1-13 (VB10) (-) - c1-12 (VB12) (+)
|
Always
|
28.8 to 33.6 V
|
c1-12 (VB12) (-) - c1-11 (VB14) (+)
|
Always
|
28.8 to 33.6 V
|
c1-11 (VB14) (-) - c1-12 (VB15) (+)
|
Always
|
14.4 to 16.8 V
|
c1-2 (VB15) (-) - c1-10 (VB16) (+)
|
Always
|
14.4 to 16.8 V
|
c1-10 (VB16) (-) - c1-1 (VB17) (+)
|
Always
|
14.4 to 16.8 V
|
|
|
*a
|
Component with harness connected
(Battery Voltage Sensor)
|
|
|
CAUTION:
Make sure not to cross the electrodes of an electrical tester measurement terminals.
NOTICE:
Make sure to check the polarity of each terminal (positive (+) or negative (-)) before connecting a tester.
(d) Install the No. 1 HV battery shield panel.
|