Last Modified: 02-14-2025 6.11:8.1.0 Doc ID: RM100000002Q101
Model Year Start: 2025 Model: RAV4 Prod Date Range: [11/2024 -           ]
Title: DOOR LOCK: KEY REMINDER WARNING SYSTEM: DATA LIST / ACTIVE TEST; 2025 MY RAV4 RAV4 HV [11/2024 -        ]

DATA LIST / ACTIVE TEST

DATA LIST

HINT:

Using the Techstream to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.

NOTICE:

In the following table, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.

(a) Read the Data List according to the display on the Techstream.

Body Electrical > Main Body > Data List

Tester Display

Measurement Item

Range

Normal Condition

Diagnostic Note

FL Door Courtesy Switch Status

Front door courtesy light switch assembly RH signal

Close or Open

Close: Front door LH closed

Open: Front door LH open

-

Key Unlock Warning Switch

Unlock warning switch

OFF or ON

OFF: Ignition key not inserted

ON: Ignition key inserted

-

ACTIVE TEST

HINT:

Using the Techstream to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.

(a) Perform the Active Test according to the display on the Techstream.

Body Electrical > Combination Meter > Active Test

Tester Display

Measurement Item

Control Range

Diagnostic Note

Buzzer Operation (800Hz, Vol L, W/ Damping)

Combination meter buzzer

  • Frequency: 800Hz
  • Volume: Large
  • Fading tone

ON

-